{"product_id":"siemens-6es7675-1dk30-0db0-simatic-ipc427c-microbox-pc","title":"Siemens 6ES7675-1DK30-0DB0 SIMATIC IPC427C Microbox PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis product is a Siemens 6ES7675-1DK30-0DB0, a compact SIMATIC IPC427C Microbox PC bundle designed for demanding automation tasks. It is equipped with an \u003cstrong\u003eIntel Core 2 Duo 1.2 GHz processor\u003c\/strong\u003e with an \u003cstrong\u003e800 MHz Front Side Bus (FSB)\u003c\/strong\u003e. The system includes \u003cstrong\u003e2 GB of DDR3 1066 SODIMM RAM\u003c\/strong\u003e and a \u003cstrong\u003e4 GB CompactFlash card\u003c\/strong\u003e for storage, accessible to the user. This specific bundle comes pre-installed with Windows Embedded Standard and WinAC RTX software, providing a ready-to-deploy platform for PC-based control. Connectivity is handled by two 1 Gbit Industrial Ethernet ports and one PROFIBUS DP interface.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eProcessor: Intel Core 2 Duo running at 1.2 GHz\u003c\/li\u003e\n  \u003cli\u003eMemory: 2 GB DDR3 1066 SODIMM\u003c\/li\u003e\n  \u003cli\u003eStorage: 4 GB accessible CompactFlash card\u003c\/li\u003e\n  \u003cli\u003eIndustrial Networking: Dual 1 Gbit Industrial Ethernet (IE) ports\u003c\/li\u003e\n  \u003cli\u003eFieldbus Connectivity: Integrated PROFIBUS DP (PB DP) port\u003c\/li\u003e\n  \u003cli\u003ePre-installed Software: Windows Embedded Standard and WinAC RTX\u003c\/li\u003e\n  \u003cli\u003eCompact, fanless design suitable for control cabinet mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003ePC-based automation and process control\u003c\/li\u003e\n  \u003cli\u003eData acquisition, logging, and gateway functions\u003c\/li\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) and SCADA applications\u003c\/li\u003e\n  \u003cli\u003eMotion control and robotics\u003c\/li\u003e\n  \u003cli\u003eEmbedded machine control in manufacturing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC IPC427C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMicrobox PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIntel Core 2 Duo, 1.2 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eFront Side Bus (FSB)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e800 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMemory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2 GB DDR3 1066, SODIMM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e4 GB CompactFlash\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEthernet Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2 x 1 Gbit Industrial Ethernet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1 x PROFIBUS DP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePre-installed Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWindows Embedded Standard, WinAC RTX\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e32.20 x 28.10 x 13.10 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2.62 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e5D002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px 16px; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all power sources before installation or maintenance. This device operates with hazardous voltages. Installation must be performed by qualified personnel only, adhering to all local electrical codes and safety regulations. Failure to comply can result in severe injury, death, or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the IPC427C unit inside a suitable enclosure that provides protection against environmental factors. Ensure adequate ventilation and clearance around the unit for heat dissipation.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis ground terminal to the main protective earth (PE) busbar of the control cabinet using a low-impedance conductor. Proper grounding is essential for noise immunity and safety.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable, filtered 24V DC power supply to the designated power input terminals. Verify the polarity and voltage are correct before applying power.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Connect shielded Ethernet cables to the RJ45 ports for network communication. Connect the PROFIBUS DP cable to its respective D-sub connector. Ensure all communication cables are routed away from high-voltage power lines to prevent interference.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eInitial Power-Up:\u003c\/strong\u003e After all connections are verified, apply power to the unit. Monitor the status LEDs to confirm a successful boot sequence and initialization of the operating system.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716468011371,"sku":"6ES7675-1DK30-0DB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7675-1dk30-0db0-rnaugddzz5j_517f1c29-4392-4ced-9b98-1c19692c9aaf.jpg?v=1767083197","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7675-1dk30-0db0-simatic-ipc427c-microbox-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}