{"product_id":"siemens-6es7716-2cb11-0ec2-simatic-field-pg-m4-industrial-programming-device","title":"Siemens 6ES7716-2CB11-0EC2 SIMATIC Field PG M4 Industrial Programming Device","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7716-2CB11-0EC2 is a SIMATIC Field PG M4 Premium, a ruggedized portable computer designed for commissioning, servicing, and maintaining automation systems directly in industrial environments. This unit is powered by an \u003cstrong\u003eIntel Core i7-35X0M processor\u003c\/strong\u003e with a base clock of \u003cstrong\u003e2.9 GHz\u003c\/strong\u003e (up to 3.6 GHz with Turbo Boost) and is equipped with \u003cstrong\u003e16 GB of RAM\u003c\/strong\u003e (2x 8 GB). It features a \u003cstrong\u003e300 GB SATA solid-state drive\u003c\/strong\u003e for fast performance and a \u003cstrong\u003e15.6-inch Full HD display\u003c\/strong\u003e (1920x1080). A key feature is its dual-boot capability, offering both \u003cstrong\u003eWindows XP Professional SP3\u003c\/strong\u003e and \u003cstrong\u003eWindows 7 Ultimate SP1 (64-bit)\u003c\/strong\u003e to support a wide range of legacy and modern automation software. The device comes pre-loaded with a comprehensive suite of engineering software licenses, including STEP 7 Professional, WinCC Advanced, and STEP 5, making it a complete solution for Siemens PLC and HMI programming. It also includes specialized hardware for legacy systems, such as an integrated \u003cstrong\u003eS5 interface\u003c\/strong\u003e, an \u003cstrong\u003eS5-EPROMMER\u003c\/strong\u003e, and the corresponding S5-AG and MPI cables.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eIntel Core i7-35X0M Processor (4 MB Cache, 2.9 GHz base)\u003c\/li\u003e\n  \u003cli\u003e16 GB RAM (2 x 8 GB modules)\u003c\/li\u003e\n  \u003cli\u003e300 GB SATA Solid-State Drive (SSD)\u003c\/li\u003e\n  \u003cli\u003e15.6-inch Full HD (1920x1080) widescreen display\u003c\/li\u003e\n  \u003cli\u003eDual-boot operating systems: Windows XP Pro SP3 and Windows 7 Ultimate SP1 (64-bit)\u003c\/li\u003e\n  \u003cli\u003ePre-installed license combo for STEP 7 Prof, WinCC Advanced, and STEP 5\u003c\/li\u003e\n  \u003cli\u003eIntegrated hardware for SIMATIC S5 support, including S5 interface and S5-EPROMMER\u003c\/li\u003e\n  \u003cli\u003eIncludes DVD RW optical drive, MPI cable, and S5-AG cable\u003c\/li\u003e\n  \u003cli\u003eQWERTY keyboard with German layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003ePLC and HMI programming and configuration\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation system commissioning and startup\u003c\/li\u003e\n  \u003cli\u003eOn-site diagnostics, troubleshooting, and maintenance\u003c\/li\u003e\n  \u003cli\u003eProgram archiving and data backup for control systems\u003c\/li\u003e\n  \u003cli\u003eServicing both modern SIMATIC S7 and legacy SIMATIC S5 systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSIMATIC Field PG M4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e6ES7716-2CB11-0EC2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIndustrial Programming Device (Premium)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIntel Core i7-35X0M (4 MB Cache, 2.9 GHz, up to 3.6 GHz with Turbo Boost)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGraphics\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHD Graphic 4000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e16 GB (2 x 8 GB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e300 GB Solid-State Drive (SATA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDVD RW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e15.6-inch, Full HD (1920 x 1080)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eKeyboard\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eQWERTY (\u0026amp; German layout)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDual-boot: Windows XP Professional SP3 \/ Windows 7 Ultimate SP1 (64-bit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIncluded Software Licenses\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSTEP 7 Professional Combo (V13\/2010), WinCC Advanced Combo (V13\/WinCC flexible 2008), STEP 7 Micro\/WIN V4.0, STEP 5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIncluded Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eS5 Interface, S5-EPROMMER\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eS5-AG Cable, EPROM Adapter, MPI Cable, UK Power Supply Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e39.5 cm x 30.0 cm x 17.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e85371099\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation and Handling Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Always de-energize control panels and follow Lockout\/Tagout (LOTO) procedures before connecting or disconnecting interface cables to live automation equipment. Incorrect connections can cause equipment damage, process interruption, or personnel injury.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eUnpack the Field PG and all accessories. Visually inspect for any signs of shipping damage before applying power.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eConnect the provided UK power supply cable to the Field PG and then to a properly grounded mains outlet. Allow the battery to charge fully if required.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003ePower on the device. Use the boot menu to select the required operating system (Windows XP or Windows 7) based on the target automation system's software requirements.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eSelect the correct interface cable (e.g., MPI for S7, S5-AG for S5) and securely connect it to the corresponding port on the Field PG and the target automation device.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eLaunch the appropriate engineering software (e.g., STEP 7, STEP 5) and configure the communication interface settings to establish a connection with the controller.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eAlways operate the device on a stable, level surface to ensure adequate ventilation and prevent accidental falls. Avoid exposure to excessive moisture, dust, or vibration.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715758616939,"sku":"6ES7716-2CB11-0EC2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7716-2cb11-0ec2-avnxlyt0zmc_9419c4be-ee9d-4335-afbf-4bd60f6de5a5.jpg?v=1767070416","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7716-2cb11-0ec2-simatic-field-pg-m4-industrial-programming-device","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}