{"product_id":"siemens-6es7716-2da03-0db3-simatic-field-pg-m4-premium-programming-device","title":"Siemens 6ES7716-2DA03-0DB3 SIMATIC Field PG M4 Premium Programming Device","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6ES7716-2DA03-0DB3\u003c\/strong\u003e is a SIMATIC Field PG M4 Premium programming device designed for industrial automation engineering tasks. This robust portable workstation features a Core i7-35X0M processor, 8 GB of RAM, and a 480 GB SATA Solid-State Drive, providing reliable performance for demanding applications. It includes a 15.6-inch HD Ready display and a QWERTY (and German) keyboard. The device comes pre-installed with a dual-boot operating system (Windows XP Professional SP3 and Windows 7 Ultimate SP1 64-bit) and a comprehensive suite of Siemens engineering software, including licenses for STEP7 Professional combo (V13\/2010), WinCC Advanced combo (V13\/WinCC flexible 2008), and STEP 7 Micro\/WIN V4.0. An MPI cable is included for immediate connectivity.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore i7-35X0M Processor (2.9 GHz, up to 3.6 GHz with Turbo Boost Technology, 4 MB Cache)\u003c\/li\u003e\n\u003cli\u003e8 GB RAM\u003c\/li\u003e\n\u003cli\u003e480 GB SATA Solid-State Drive\u003c\/li\u003e\n\u003cli\u003eDVD RW Optical Drive\u003c\/li\u003e\n\u003cli\u003eHD Graphic 4000\u003c\/li\u003e\n\u003cli\u003e15.6-inch HD Ready Display (1366x768)\u003c\/li\u003e\n\u003cli\u003eQWERTY (and German) Keyboard Layout\u003c\/li\u003e\n\u003cli\u003eDual Boot Operating System: Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit)\u003c\/li\u003e\n\u003cli\u003ePre-installed Software Licenses: STEP7 Professional combo (V13\/2010), WinCC Advanced combo (V13\/WinCC flexible 2008), STEP 7 Micro\/WIN V4.0\u003c\/li\u003e\n\u003cli\u003eIncludes MPI Cable\u003c\/li\u003e\n\u003cli\u003eWithout S5 Interface and S5-EPROMMER\u003c\/li\u003e\n\u003cli\u003ePower supply cable for USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOn-site PLC and HMI programming and configuration\u003c\/li\u003e\n\u003cli\u003eIndustrial automation system commissioning and diagnostics\u003c\/li\u003e\n\u003cli\u003eSoftware development and testing for SIMATIC control systems\u003c\/li\u003e\n\u003cli\u003eMaintenance and troubleshooting of industrial machinery\u003c\/li\u003e\n\u003cli\u003eMobile engineering workstation for factory environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Field PG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eField PG M4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePremium Programming Device\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore i7-35X0M (4M Cache, 2.9 GHz, up to 3.6 GHz with Turbo Boost)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 GB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e480 GB SATA Solid-State Drive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDVD RW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eGraphics\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHD Graphic 4000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15.6\" HD Ready (1366x768)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eKeyboard\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eQWERTY (and German)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDual Boot (Windows XP Prof SP3, Windows 7 Ultimate SP1 64-bit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePre-installed Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSTEP7 Prof combo (V13\/2010), WinCC Advanced combo (V13\/WinCC flexible 2008), STEP 7 Micro\/WIN V4.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eIncluded Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMPI cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSoftware Version\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eV13.0.0.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eS5 Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eS5-EPROMMER\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFor USA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e39.50 x 30.00 x 17.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e84713000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnpacking and Inspection:\u003c\/strong\u003e Carefully unpack the Field PG and inspect for any visible damage during transit. Retain original packaging for potential future transport.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the provided power supply cable to the Field PG and a suitable AC power outlet. Ensure the power source meets the device's electrical requirements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInitial Boot-up:\u003c\/strong\u003e Power on the Field PG. The dual-boot system allows selection between Windows XP and Windows 7. Select the desired operating system for your application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e Verify the pre-installed Siemens engineering software (STEP7, WinCC, Micro\/WIN) is correctly installed and licensed. Perform any necessary updates or configurations as per project requirements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect any required external peripherals such as external monitors, USB devices, or network cables. The included MPI cable can be used for direct connection to compatible SIMATIC devices.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Operate the Field PG within specified environmental conditions to ensure optimal performance and longevity. Avoid extreme temperatures, humidity, and dusty environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eData Backup:\u003c\/strong\u003e Regularly back up project data and critical files to external storage to prevent data loss.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716356567403,"sku":"6ES7716-2DA03-0DB3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7716-2da03-0db3-owj2bojn3qy_0c7f7e13-2be8-4570-8ff4-8e601fc1dccb.jpg?v=1767081168","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7716-2da03-0db3-simatic-field-pg-m4-premium-programming-device","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}