{"product_id":"siemens-6gk1503-2cb00-profibus-olm-g11-v4-0-optical-link-module","title":"Siemens 6GK1503-2CB00 PROFIBUS OLM\/G11 V4.0 Optical Link Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK1503-2CB00\u003c\/strong\u003e is a PROFIBUS OLM\/G11 V4.0 optical link module designed to provide reliable communication within industrial automation networks. This module integrates one \u003cstrong\u003eRS485 electrical interface\u003c\/strong\u003e with a single glass fiber optic cable interface, featuring two \u003cstrong\u003eBFOC sockets\u003c\/strong\u003e for flexible and efficient data transmission over extended distances. It ensures stable connectivity and precise signal transfer, making it suitable for demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK1503-2CB00\u003c\/strong\u003e supports a wide range of PROFIBUS transfer rates, from \u003cstrong\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/strong\u003e, and also includes support for \u003cstrong\u003e45.45 kbit\/s\u003c\/strong\u003e for PROFIBUS PA applications. This versatility allows for seamless integration into existing PROFIBUS networks while maintaining high data integrity. For enhanced operational reliability, the module incorporates a signaling contact and a dedicated test port for straightforward monitoring and maintenance.\u003c\/p\u003e\n\u003cp\u003eOperating with a rated supply voltage of \u003cstrong\u003e24 V DC\u003c\/strong\u003e and an operational range from \u003cstrong\u003e18.8 to 28.8 V DC\u003c\/strong\u003e, the Siemens \u003cstrong\u003e6GK1503-2CB00\u003c\/strong\u003e is engineered for reliable function under varying power conditions. It also features a built-in fuse at the power supply input, providing protection against potential electrical faults and contributing to increased system safety and longevity. With its robust performance and compact design, the module facilitates dependable optical communication in harsh industrial settings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePROFIBUS OLM\/G11 V4.0 Optical Link Module.\u003c\/li\u003e\n  \u003cli\u003eCombines one RS485 electrical interface with a glass fiber optic interface.\u003c\/li\u003e\n  \u003cli\u003eEquipped with two BFOC sockets for fiber optic cable connection.\u003c\/li\u003e\n  \u003cli\u003eSupports PROFIBUS transfer rates from 9.6 kbit\/s to 12 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eIncludes support for 45.45 kbit\/s for PROFIBUS PA applications.\u003c\/li\u003e\n  \u003cli\u003eFeatures a signaling contact and a dedicated test port for diagnostics.\u003c\/li\u003e\n  \u003cli\u003eRated supply voltage of 24 V DC with an operational range of 18.8 to 28.8 V DC.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in fuse at the power supply input for electrical protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation networks requiring PROFIBUS communication.\u003c\/li\u003e\n  \u003cli\u003eSystems needing conversion between RS485 electrical and fiber optic PROFIBUS segments.\u003c\/li\u003e\n  \u003cli\u003eApplications requiring extended PROFIBUS network distances.\u003c\/li\u003e\n  \u003cli\u003eIntegration into existing PROFIBUS DP and PROFIBUS PA infrastructures.\u003c\/li\u003e\n  \u003cli\u003eDeployment in demanding industrial environments where robust data transmission is critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e6GK1503-2CB00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eOptical Link Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Status\u003c\/td\u003e\n      \u003ctd\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eGERMANY\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003ePLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Service\u003c\/td\u003e\n      \u003ctd\u003eEthernet router\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s (PROFIBUS), 45.45 kbit\/s (PROFIBUS PA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x RS485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptical Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x Glass Fiber Optic, 2 x BFOC sockets\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperational Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e18.8 to 28.8 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection\u003c\/td\u003e\n      \u003ctd\u003eBuilt-in fuse at power supply input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnit Weight\u003c\/td\u003e\n      \u003ctd\u003e0.34 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0.95 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHS CODE\u003c\/td\u003e\n      \u003ctd\u003e8537101190\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Order Quantity (MOQ)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect the module to a stable 24 V DC power source. Ensure the supply voltage remains within the operational range of 18.8 V DC to 28.8 V DC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e Connect the RS485 electrical interface to the PROFIBUS DP segment using appropriate shielded cabling and termination practices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFiber Optic Connection:\u003c\/strong\u003e Connect the glass fiber optic cable to the two BFOC sockets. Ensure proper fiber polarity and secure connections to maintain signal integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding of the module and associated cabling to minimize electromagnetic interference and ensure safe operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Integrate the module into the PROFIBUS network configuration according to the system's design and addressing scheme.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Utilize the signaling contact and test port for initial commissioning checks and ongoing operational monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Always de-energize the system before making or breaking electrical connections to prevent electrical shock or damage to components.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695204004203,"sku":"6GK1503-2CB00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6gk1503-2cb00-optical-link-module-ioehrg11xzk_cac25ddb-1773-4c86-b705-8e65997044c1.jpg?v=1766130613","url":"https:\/\/www.plcprotech.com\/products\/siemens-6gk1503-2cb00-profibus-olm-g11-v4-0-optical-link-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}