{"product_id":"siemens-6gk5302-7gd00-2ga3-scalance-x302-7eec-managed-ie-switch","title":"Siemens 6GK5302-7GD00-2GA3 SCALANCE X302-7EEC Managed IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5302-7GD00-2GA3\u003c\/strong\u003e is a compact, managed Industrial Ethernet (IE) switch from the \u003cstrong\u003eSCALANCE X302-7EEC\u003c\/strong\u003e series. This device is engineered for industrial network applications, offering a versatile port configuration including two 10\/100\/1000 Mbit\/s RJ45 ports and seven 100 Mbit\/s LC Fiber Optic (FO) ports. It functions as a PROFINET IO device and incorporates network management capabilities, an integrated redundancy manager, and support for standard office features such as RSTP, VLAN, and IGMP. Diagnostic feedback is provided via LED indicators and an error signaling contact, with configuration options accessible through a select\/set pushbutton. Designed for robust industrial environments, the switch features a 24 V DC redundant power supply unit and conformal coating, with a C-plug included in the scope of delivery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Industrial Ethernet switch functionality\u003c\/li\u003e\n\u003cli\u003e2x 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/li\u003e\n\u003cli\u003e7x 100 Mbit\/s LC Fiber Optic (FO) ports\u003c\/li\u003e\n\u003cli\u003ePROFINET IO device support\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy manager\u003c\/li\u003e\n\u003cli\u003eSupports office features (RSTP, VLAN, IGMP)\u003c\/li\u003e\n\u003cli\u003eLED diagnostics and error signaling contact\u003c\/li\u003e\n\u003cli\u003eSelect\/set pushbutton for configuration\u003c\/li\u003e\n\u003cli\u003e24 V DC redundant power supply capability\u003c\/li\u003e\n\u003cli\u003eConformal coating for environmental protection\u003c\/li\u003e\n\u003cli\u003eC-plug included for easy replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Ethernet networks requiring managed switching and diagnostic features.\u003c\/li\u003e\n\u003cli\u003eIntegration into PROFINET IO systems for data exchange and control.\u003c\/li\u003e\n\u003cli\u003eApplications demanding high availability through network redundancy.\u003c\/li\u003e\n\u003cli\u003eDeployment in environments where fiber optic communication is beneficial for extended distances or electrical isolation.\u003c\/li\u003e\n\u003cli\u003eUse in harsh industrial settings due to conformal coating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5302-7GD00-2GA3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE X302-7EEC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged IE Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e7x 100 Mbit\/s LC FO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC (redundant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSpecial Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO device, Redundancy Manager, Conformal Coating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e21.60 x 11.00 x 14.30 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.60 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRJ45 Ports:\u003c\/strong\u003e For standard Ethernet connections at 10\/100\/1000 Mbit\/s.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLC Fiber Optic Ports:\u003c\/strong\u003e For 100 Mbit\/s fiber optic Ethernet connections.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Supply Terminals:\u003c\/strong\u003e For redundant 24 V DC power input.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eError Signaling Contact:\u003c\/strong\u003e For external fault indication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSelect\/Set Pushbutton:\u003c\/strong\u003e For local device configuration and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energization:\u003c\/strong\u003e Ensure all power to the installation area is disconnected before mounting or wiring the device.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the SCALANCE switch in a suitable industrial enclosure or on a DIN rail, ensuring adequate ventilation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC redundant power supply to the designated terminals, observing correct polarity. Utilize both inputs for redundancy where required.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a robust protective earth (PE) connection to the device's grounding terminal to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect RJ45 Ethernet cables to the respective ports. For fiber optic connections, use appropriate LC fiber optic cables, ensuring proper handling to prevent damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Perform initial configuration using the select\/set pushbutton or via network management tools to integrate the switch into the existing network infrastructure.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e After installation and power-up, verify LED diagnostics for correct operation and network status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716400509291,"sku":"6GK5302-7GD00-2GA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5302-7gd00-2ga3-tnxcmeve33q_5b02fef7-f295-4eea-aa26-c2cd6a3389a6.jpg?v=1767082074","url":"https:\/\/www.plcprotech.com\/products\/siemens-6gk5302-7gd00-2ga3-scalance-x302-7eec-managed-ie-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}