{"product_id":"siemens-6se7016-2fb87-1fd0-simovert-masterdrives-du-dt-filter","title":"Siemens 6SE7016-2FB87-1FD0 SIMOVERT MASTERDRIVES du\/dt Filter","description":"\u003cp\u003eThe \u003cstrong\u003e6SE7016-2FB87-1FD0\u003c\/strong\u003e is a \u003cstrong\u003eSIMOVERT MASTERDRIVES du\/dt filter\u003c\/strong\u003e designed to protect motor insulation and extend the operational lifespan of drive systems. By reducing voltage rise times (du\/dt) at the output of frequency inverters, this filter mitigates high-frequency voltage peaks that can lead to premature motor failure. It is compatible with three-phase supply configurations, supporting 380–460 V AC at 6.1 A or 500–575 V AC at 6.2 A, ensuring versatility across different industrial power architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Reduces steep voltage slopes (du\/dt) to protect motor windings and insulation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for use with SIMOVERT MASTERDRIVES inverter configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Ratings:\u003c\/strong\u003e Supports 6.1 A at 380–460 V AC and 6.2 A at 500–575 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Design:\u003c\/strong\u003e Industrial-grade construction suitable for continuous operation in demanding production environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Acts as a base unit for drive systems, allowing for additional technical options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtection of AC motors in high-frequency switching drive environments.\u003c\/li\u003e\n\u003cli\u003eExtension of cable lengths between inverters and motors.\u003c\/li\u003e\n\u003cli\u003eIndustrial production lines utilizing SIMOVERT MASTERDRIVES power sections.\u003c\/li\u003e\n\u003cli\u003eRetrofitting and maintenance of legacy automation drive systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSIMOVERT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003eMASTERDRIVES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003edu\/dt Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (1)\u003c\/td\u003e\n\u003ctd\u003e380-460 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (1)\u003c\/td\u003e\n\u003ctd\u003e6.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (2)\u003c\/td\u003e\n\u003ctd\u003e500-575 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (2)\u003c\/td\u003e\n\u003ctd\u003e6.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxHxD)\u003c\/td\u003e\n\u003ctd\u003e48.30 x 40.60 x 35.60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e20.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e Install the filter as close to the inverter output as possible to minimize the length of unfiltered cable runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Ensure adequate ventilation in the control cabinet; the filter generates heat during operation and requires unobstructed airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain high-quality electrical grounding connections to ensure effective suppression of electromagnetic interference and safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for connections between the filter and the motor to comply with electromagnetic compatibility (EMC) standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716775768427,"sku":"6SE7016-2FB87-1FD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6se7016-2fb87-1fd0-gedef5lvxak_064ac1e2-7a61-4d80-82a7-82acea4051dc.jpg?v=1767089361","url":"https:\/\/www.plcprotech.com\/products\/siemens-6se7016-2fb87-1fd0-simovert-masterdrives-du-dt-filter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}