{"product_id":"siemens-7ml1201-1ee00-sitrans-the-probe-ultrasonic-level-transmitter","title":"Siemens 7ML1201-1EE00 SITRANS The Probe Ultrasonic Level Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003e7ML1201-1EE00\u003c\/strong\u003e is a \u003cstrong\u003eSITRANS The Probe\u003c\/strong\u003e ultrasonic level transmitter designed for continuous, non-contact level monitoring of liquids and slurries. This device provides reliable measurement performance with a maximum range of 5 m (16.4 ft). Featuring a robust construction with a PVDF copolymer transducer, it is engineered for various industrial liquid applications. This model utilizes a 3-wire configuration with relay output for straightforward integration into existing automation systems. While this specific unit is currently in a phase-out status, it remains a recognized solution for established process control requirements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Contact Measurement:\u003c\/strong\u003e Prevents material buildup and sensor degradation by eliminating physical contact with the media.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Capable of monitoring levels up to 5 m (16.4 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Connection:\u003c\/strong\u003e Equipped with a 2-inch NPT (Taper, ANSI\/ASME B1.20.1) connection for secure installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Construction:\u003c\/strong\u003e Durable PVDF copolymer transducer suitable for various chemical and liquid environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 3-wire design with integrated relay output for process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e Operates on 24 V DC power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStorage tank level monitoring.\u003c\/li\u003e\n\u003cli\u003eLiquid inventory management.\u003c\/li\u003e\n\u003cli\u003eSlurry level detection in industrial processes.\u003c\/li\u003e\n\u003cli\u003eGeneral process vessel level measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSITRANS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e5 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e2 inch NPT (Taper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Material\u003c\/td\u003e\n\u003ctd\u003ePVDF copolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e3-wire, Relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, RCM, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.00 cm x 31.00 cm x 93.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the transmitter at the top of the tank or vessel, ensuring the face of the transducer is parallel to the liquid surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a clear path between the transducer and the material surface to avoid interference from tank obstructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Ensure proper shielding of signal cables to prevent electromagnetic interference. Follow local electrical standards for 24 V DC installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Verify the sensor configuration and set the zero and span points according to the specific vessel dimensions and process requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Factors:\u003c\/strong\u003e While the transducer material is robust, ensure the installation location protects the electronics housing from direct flooding or excessive environmental exposure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716775244139,"sku":"7ML1201-1EE00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/7ml1201-1ee00-og4gh0cl1ds_7dc191c6-3cbb-4fe6-9f61-08f9a87ff1a6.jpg?v=1767089344","url":"https:\/\/www.plcprotech.com\/products\/siemens-7ml1201-1ee00-sitrans-the-probe-ultrasonic-level-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}