{"product_id":"siemens-simatic-s7-s7-1500-6es7518-4ap00-0ab0-standard-cpus","title":"Siemens Simatic S7 S7-1500 6ES7518-4AP00-0AB0 Standard CPUs","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6ES7518-4AP00-0AB0\u003c\/strong\u003e is a \u003cstrong\u003ecentral processing unit\u003c\/strong\u003e designed for \u003cstrong\u003emachine and process automation in SIMATIC S7-1500 systems\u003c\/strong\u003e. The \u003cstrong\u003eCPU 1518-4 PN\/DP\u003c\/strong\u003e provides \u003cstrong\u003e6 Mbyte of program work memory\u003c\/strong\u003e and \u003cstrong\u003e60 Mbyte of data work memory\u003c\/strong\u003e, with a typical bit operation processing time of \u003cstrong\u003e1 ns\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe CPU executes control programs, processes local and distributed I\/O data, and supports motion control and PID regulation. Its communication architecture combines \u003cstrong\u003ePROFINET IRT\u003c\/strong\u003e, \u003cstrong\u003ePROFINET RT\u003c\/strong\u003e, \u003cstrong\u003eIndustrial Ethernet\u003c\/strong\u003e, and \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e. X1 provides a two-port Ethernet switch for PROFINET communication, while X2 provides an additional PROFINET interface. X3 supports Ethernet communication, including Gigabit Ethernet, and X4 operates as a PROFIBUS DP master.\u003c\/p\u003e\n\u003cp\u003eEngineering is performed using \u003cstrong\u003eSTEP 7 in TIA Portal\u003c\/strong\u003e. A \u003cstrong\u003eSIMATIC Memory Card\u003c\/strong\u003e is required for load memory. \u003cstrong\u003eOPC UA Client and Server\u003c\/strong\u003e functionality requires the \u003cstrong\u003eLarge runtime license\u003c\/strong\u003e. 6ES75184AP000AB0_datasheet_en.pdf\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotion Control technology objects for speed-controlled axes, positioning axes, synchronous axes, and external encoders.\u003c\/li\u003e\n\u003cli\u003ePID_Compact, PID_3Step, and PID-Temp controllers with integrated optimization.\u003c\/li\u003e\n\u003cli\u003eIntegrated web server supporting standard and user-defined pages through HTTP and HTTPS.\u003c\/li\u003e\n\u003cli\u003eDiagnostic buffer, trace recording, variable monitoring, and forcing functions for commissioning.\u003c\/li\u003e\n\u003cli\u003eProgram protection, copy protection, block protection, and configurable access protection.\u003c\/li\u003e\n\u003cli\u003eConfiguration control through data records.\u003c\/li\u003e\n\u003cli\u003eProgramming support for LAD, FBD, STL, SCL, and GRAPH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine sequencing and production equipment control using distributed PROFINET I\/O.\u003c\/li\u003e\n\u003cli\u003eAutomation systems incorporating PROFIBUS DP field devices.\u003c\/li\u003e\n\u003cli\u003eSpeed and positioning control for motor-driven machinery.\u003c\/li\u003e\n\u003cli\u003ePID regulation of process variables, valves, and temperature.\u003c\/li\u003e\n\u003cli\u003eController data exchange with supervisory systems through OPC UA, S7 communication, or MODBUS TCP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrder Number\u003c\/th\u003e\n\u003cth\u003eProduct Designation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e6ES7518-4AP00-0AB0\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500 CPU 1518-4 PN\/DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU designation\u003c\/td\u003e\n\u003ctd\u003eCPU 1518-4 PN\/DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware functional status\u003c\/td\u003e\n\u003ctd\u003eFS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware version\u003c\/td\u003e\n\u003ctd\u003eV2.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngineering software\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V17 or higher for FW V2.9; V13 or higher for FW V1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible supply voltage range\u003c\/td\u003e\n\u003ctd\u003e19.2 V to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current consumption\u003c\/td\u003e\n\u003ctd\u003e1.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower failure buffering time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfeed power to the backplane bus\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption from the backplane bus, balanced\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical power loss\u003c\/td\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated program work memory\u003c\/td\u003e\n\u003ctd\u003e6 Mbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated data work memory\u003c\/td\u003e\n\u003ctd\u003e60 Mbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIMATIC Memory Card\u003c\/td\u003e\n\u003ctd\u003eRequired; 1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load memory\u003c\/td\u003e\n\u003ctd\u003e32 Gbyte using SIMATIC Memory Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical bit operation processing time\u003c\/td\u003e\n\u003ctd\u003e1 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical word operation processing time\u003c\/td\u003e\n\u003ctd\u003e2 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical fixed-point arithmetic processing time\u003c\/td\u003e\n\u003ctd\u003e2 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical floating-point arithmetic processing time\u003c\/td\u003e\n\u003ctd\u003e6 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput address area\u003c\/td\u003e\n\u003ctd\u003e32 kbyte; all inputs are in the process image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput address area\u003c\/td\u003e\n\u003ctd\u003e32 kbyte; all outputs are in the process image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum modules per rack\u003c\/td\u003e\n\u003ctd\u003e32; CPU + 31 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of rack rows\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated PROFINET IO Controllers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated PROFIBUS DP masters\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PROFINET IO Devices on X1\u003c\/td\u003e\n\u003ctd\u003e512; including a maximum of 64 IRT devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PROFINET IO Devices on X2\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PROFIBUS DP devices on X4\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum distributed I\/O devices, combined\u003c\/td\u003e\n\u003ctd\u003e1 000 across AS-i, PROFIBUS, and PROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet transmission rates\u003c\/td\u003e\n\u003ctd\u003e100 Mbps; 1000 Mbps available only on X3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PROFIBUS transmission rate\u003c\/td\u003e\n\u003ctd\u003e12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum communication connections\u003c\/td\u003e\n\u003ctd\u003e384 through integrated interfaces and connected CPs\/CMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum connections through integrated interfaces\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPC UA functionality\u003c\/td\u003e\n\u003ctd\u003eClient and Server; Large runtime license required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional industrial protocol\u003c\/td\u003e\n\u003ctd\u003eMODBUS TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay diagonal\u003c\/td\u003e\n\u003ctd\u003e6.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature, horizontal installation\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC; display switches off at a typical operating temperature of 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature, vertical installation\u003c\/td\u003e\n\u003ctd\u003e0 degC to 40 degC; display switches off at a typical operating temperature of 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage and transportation temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum installation altitude\u003c\/td\u003e\n\u003ctd\u003e5 000 m; restrictions apply above 2 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, W x H x D\u003c\/td\u003e\n\u003ctd\u003e175 mm x 147 mm x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate weight\u003c\/td\u003e\n\u003ctd\u003e1 988 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eTwo RJ45 ports with integrated switch; PROFINET IO Controller and IO Device functions; RT and IRT communication; media redundancy support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX2\u003c\/td\u003e\n\u003ctd\u003eOne RJ45 port; PROFINET IO Controller and IO Device functions with RT communication; no IRT or media redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003eOne RJ45 Ethernet port; SIMATIC communication, Open IE communication, and web server access; supports 1000 Mbps; no PROFINET IO Controller or IO Device function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003eOne RS485 port; PROFIBUS DP master communication up to 12 Mbit\/s; no PROFIBUS DP device function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate power before connecting the DC supply, and verify supply polarity and the permitted voltage range.\u003c\/li\u003e\n\u003cli\u003eProvide cabinet thermal management for the typical power loss of 24 W. Observe the operating temperature limits for the selected mounting orientation.\u003c\/li\u003e\n\u003cli\u003eInstall a SIMATIC Memory Card for load memory before commissioning.\u003c\/li\u003e\n\u003cli\u003eConnect IRT applications through X1. Use X2 for additional PROFINET RT communication and X3 for Ethernet communication.\u003c\/li\u003e\n\u003cli\u003eConfigure X4 as a PROFIBUS DP master when connecting PROFIBUS field devices.\u003c\/li\u003e\n\u003cli\u003eMatch the TIA Portal project configuration to the CPU firmware version.\u003c\/li\u003e\n\u003cli\u003eApply the specified installation restrictions when operating above 2 000 m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArea\u003c\/th\u003e\n\u003cth\u003eApprovals and Declarations\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral product approvals\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, UL, RCM, EAC, TUEV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous locations\u003c\/td\u003e\n\u003ctd\u003eFM, UL, CCC-Ex, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaritime applications\u003c\/td\u003e\n\u003ctd\u003eABS, Bureau Veritas, DNV, Lloyd's Register, NK, RINA, RMRS, CCS, KR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental declarations\u003c\/td\u003e\n\u003ctd\u003eChina RoHS, EPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial communication\u003c\/td\u003e\n\u003ctd\u003ePROFINET, PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716286345579,"sku":"6ES7518-4AP00-0AB0","price":9500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7518-4ap00-0ab0-upwzzh5harp_6f0e697e-3e8a-49dc-8654-766fe69ae616.jpg?v=1767080305","url":"https:\/\/www.plcprotech.com\/products\/siemens-simatic-s7-s7-1500-6es7518-4ap00-0ab0-standard-cpus","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}