{"product_id":"siemens-sitrans-7me6110-1ma20-2aa1","title":"Siemens Sitrans 7ME6110-1MA20-2AA1","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 7ME6110-1MA20-2AA1\u003c\/strong\u003e is a \u003cstrong\u003eSITRANS FM MAG 1100 electromagnetic flow sensor\u003c\/strong\u003e featuring a wafer design with a \u003cstrong\u003eDN 6 (1\/4 inch)\u003c\/strong\u003e diameter. Engineered for accurate volumetric flow measurement of conductive liquids, this sensor is designed for industrial process applications in the water and wastewater, pharmaceutical, and chemical industries. Constructed with a ceramic liner and platinum electrodes, it is configured for remote transmitters (transmitter ordered separately) and includes a metric polyamide terminal box. It maintains an active product lifecycle status, delivering reliable performance for industrial fluid measurement architectures.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSITRANS FM MAG 1100 electromagnetic flow sensor in a wafer design\u003c\/li\u003e\n\u003cli\u003eNominal diameter of DN 6 (1\/4 inch) for precise fluid measurement\u003c\/li\u003e\n\u003cli\u003eCeramic liner equipped with platinum electrodes for chemical resistance\u003c\/li\u003e\n\u003cli\u003eDesigned for remote transmitter configurations (transmitter required separately)\u003c\/li\u003e\n\u003cli\u003eMetric polyamide terminal box for secure signal wiring connection\u003c\/li\u003e\n\u003cli\u003eActive product lifecycle status within the Siemens Sitrans range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater and wastewater treatment flow monitoring\u003c\/li\u003e\n\u003cli\u003eChemical processing and dosing measurement lines\u003c\/li\u003e\n\u003cli\u003ePharmaceutical manufacturing fluid transfer loops\u003c\/li\u003e\n\u003cli\u003eIndustrial conductive liquid flow measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrands\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSitrans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Product\u003c\/td\u003e\n\u003ctd\u003eFlow sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003eWafer Design (DN 6 \/ 1\/4 Inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Box\u003c\/td\u003e\n\u003ctd\u003eMetric Polyamide Terminal Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the pipeline is completely depressurized and drained before installing or servicing the flow sensor.\u003c\/li\u003e\n\u003cli\u003eMount the wafer-style sensor securely between mating pipe flanges, ensuring correct alignment with the inner pipe diameter.\u003c\/li\u003e\n\u003cli\u003eObserve proper flow direction arrows marked on the sensor body to guarantee accurate measurement readings.\u003c\/li\u003e\n\u003cli\u003eConnect the sensor signal cable from the terminal box to a compatible remote transmitter, ensuring proper cable shielding.\u003c\/li\u003e\n\u003cli\u003eVerify grounding and electrical continuity across the pipeline flanges prior to system operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716772688235,"sku":"7ME6110-1MA20-2AA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/7me6110-1ma20-2aa1-vpxi0ycvcdb_f522b2e5-e1f4-40bd-8314-06755f0f4523.jpg?v=1767089254","url":"https:\/\/www.plcprotech.com\/products\/siemens-sitrans-7me6110-1ma20-2aa1","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}