{"product_id":"vfd110b43a-delta-vfd-b-series-high-performance-ac-drive","title":"VFD110B43A DELTA VFD-B Series High-Performance AC Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFD110B43A (VFD110B43A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust 11 kW (15 HP) industrial Variable Frequency Drive designed for general-purpose applications requiring high torque and precise speed control. As a cornerstone of Delta’s VFD-B series, this drive is engineered for NEMA 1 environments, providing reliable performance for conveyors, compressors, and mid-sized machine tools. In heavy-duty industrial settings, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFD110B43A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures system resilience with a 150% overload endurance for 60 seconds, effectively preventing nuisance tripping during high-inertia startups and sudden load fluctuations in manufacturing lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VFD110B43A utilizes an advanced microprocessor-controlled PWM system, offering a frequency setting resolution of 0.01 Hz for high-precision speed regulation. The hardware is optimized for harsh electrical environments, featuring programmable stall prevention levels from 20% to 250% to protect the motor and drive during overcurrent or overvoltage conditions. To protect mechanical integrity, the drive includes three-zone skip frequency settings, allowing engineers to bypass specific resonance frequencies (0.1 to 400 Hz) that could otherwise cause vibration-induced wear on coupled mechanical components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD110B43A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta Electronics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD-B Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplicable Motor Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 kW (15 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460V Three Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150% of rated current for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStall Prevention Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20% to 250% of rated current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air Cooling (Fan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBelow 90% RH (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 60 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I eliminate mechanical vibration at specific speeds with the VFD110B43A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUtilize the \"Skip Frequency\" parameters to define up to three distinct zones across the 0.1 to 400 Hz range. This prevents the drive from running at steady-state frequencies that coincide with the natural resonance of your mechanical system, such as gearboxes or fan blades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the drive trips on an Overload (OL) fault during startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the motor's rated current is correctly entered into the drive parameters. If the load inertia is high, consider increasing the acceleration time or adjusting the S-curve settings. The VFD110B43A is rated for 150% current for 60 seconds; if the peak demand exceeds this, a higher capacity drive may be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in high-altitude environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, but derating is typically required. For every 1000 meters above sea level, the output current should be derated by approximately 1%. Ensure the ambient humidity remains below 90% RH and is strictly non-condensing to protect the internal power modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFan Maintenance and Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VFD110B43A utilizes forced air cooling. To ensure the 13 kg unit remains within safe operating temperatures, provide at least 150 mm of vertical clearance. Periodically inspect the cooling fans for dust accumulation, especially in textile or woodworking applications, as reduced airflow can lead to premature aging of the electrolytic capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Wiring and Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-speed fuses or a dedicated molded case circuit breaker (MCCB) on the 460V input side. To comply with EMC standards and reduce electrical noise, use shielded power cables for the motor connection and ensure the ground wire cross-section is sufficient to handle potential leakage currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStall Prevention Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSet the stall prevention level based on the specific load profile. For constant torque applications like conveyors, a setting of 150-180% is standard. For variable torque loads like centrifugal pumps, a lower setting may be utilized to provide tighter motor protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102148911467,"sku":"VFD110B43A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd110b43a-f1s2t2x5fuy.png?v=1776138063","url":"https:\/\/www.plcprotech.com\/products\/vfd110b43a-delta-vfd-b-series-high-performance-ac-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}