{"product_id":"vfd1320cp43b-21-delta-cp2000-series-fan-pump-vector-control-drive","title":"VFD1320CP43B-21 DELTA CP2000 Series Fan\/Pump Vector Control Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFD1320CP43B-21 (VFD1320CP43B21)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 132 kW (175 HP) Variable Frequency Drive specifically engineered for energy-intensive fluid technology applications. As part of Delta’s specialized CP2000 series, this drive utilizes advanced sensorless vector control to optimize the performance of centrifugal fans and pumps in large-scale HVAC systems, water treatment facilities, and industrial cooling towers. By implementing precise PID control and a multi-pump master\/slave configuration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFD1320CP43B-21\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces energy consumption and mechanical stress during start-stop cycles, providing a critical safeguard against water hammer effects and system pressure surges.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the VFD1320CP43B-21 is optimized for high-power industrial environments, featuring a robust wall-mount design with NEMA 1\/IP20 protection. The drive operates on a 460V 3-Phase input, delivering a steady 260 Amps to support heavy-duty motors. It incorporates a built-in BACnet communication protocol, making it natively compatible with Building Automation Systems (BAS). The internal logic includes a \"Fire Mode\" for emergency tunnel ventilation and \"Sleep Mode\" for pump energy savings, ensuring that the drive balances performance with rigorous safety and efficiency standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD1320CP43B-21\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta Electronics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCP2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132 kW (175 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e260 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460V 3-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSensorless Vector Control (SVC) \/ V\/f\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ NEMA 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWall Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e370 x 715.8 x 300 mm (14.57 x 28.18 x 11.81 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e66 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the VFD1320CP43B-21 handle multi-pump control without an external PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CP2000 series features a built-in 10k step PLC and multi-pump control logic. It can manage up to 8 motors simultaneously through fixed-amount or fixed-time circulation control, balancing the runtime of each pump to extend the overall equipment lifecycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Fire Mode\" and how does it affect drive protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen Fire Mode is activated via a digital input, the drive bypasses standard protective alarms (such as over-temperature) to ensure the fan continues running for smoke extraction or pressurization during an emergency, prioritizing human safety over hardware protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in high-humidity water treatment environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the drive is rated NEMA 1\/IP20, it is designed for indoor cabinet installation. For high-humidity or corrosive environments typical of water treatment, it must be installed within a secondary enclosure with appropriate thermal management to prevent condensation on the internal PCBs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLifting and Mounting Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 66 kg unit weight, always use the designated lifting eyelets located at the top of the chassis. Ensure the mounting surface is a non-combustible metal plate or reinforced concrete wall capable of supporting four times the drive's weight to prevent vibration-induced fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Displacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis drive dissipates significant heat at a 260 Amp load. Maintain a minimum vertical clearance of 200 mm above and below the unit. If multiple drives are installed in one cabinet, use a \"side-by-side\" configuration only if derating factors are applied or if high-volume forced air cooling is present to maintain an ambient temperature below 40 Celsius.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor a 132 kW motor, it is highly recommended to install a DC reactor (often built-in or optional) or an AC line reactor at the input. This reduces Total Harmonic Distortion (THD) and protects the drive's bridge rectifier from voltage spikes and line imbalances common in heavy industrial grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102149239147,"sku":"VFD1320CP43B-21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd1320cp43b-21-lmqdmx5rlaw.png?v=1776138067","url":"https:\/\/www.plcprotech.com\/products\/vfd1320cp43b-21-delta-cp2000-series-fan-pump-vector-control-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}