{"product_id":"vlt-2975-vlt2975pt4b20-danfoss-frequency-converter","title":"VLT 2975 (VLT2975PT4B20) Danfoss Frequency Converter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e195N2198 (195N2198)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust VLT 2900 series frequency converter, specifically the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLT 2975\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel, engineered for high-performance motor control in automated production lines. In heavy-duty industrial applications such as conveyor synchronization, packaging machinery, and centrifugal pumps, this drive delivers precise torque and speed regulation. Designed to maximize cabinet space and minimize thermal load, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLT2975PT4B20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures consistent operation under varying load conditions. Its integration into a control architecture is a strategic move to enhance energy efficiency and reduce mechanical wear on motor-driven systems, thereby securing the long-term reliability of the production floor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware profile of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e195N2198\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for reliability and high-speed processing in 400 V industrial networks.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLT 2975\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel, it is designed for a power rating typically suited for mid-range industrial loads, providing the necessary current to drive three-phase asynchronous motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMains Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"T4\" designation indicates compatibility with three-phase 380-480 VAC input, covering the majority of global industrial power standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"B20\" code signifies an IP20 protection rating, making it ideal for installation within clean, dry control panels where centralized airflow can be managed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures advanced motor control algorithms that allow for high dynamic response and stable low-speed torque, essential for precision positioning and startup under load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e195N2198\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT 2900 (VLT 2975)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFull Type Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT2975PT4B20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-480 VAC (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air Cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 45 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEstimated Lead Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-10 Working Days\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 195N2198 be mounted side-by-side without clearance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VLT 2900 series supports \"bookstyle\" mounting; however, because the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLT 2975\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerates significant heat during full-load operation, a minimum horizontal gap or forced enclosure ventilation is recommended to prevent thermal tripping during peak ambient temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I restore the drive to factory settings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit can be reset through the LCP (Local Control Panel) by selecting the specialized initialization parameter. This is a critical step when repurposing a drive for a different motor application to ensure no legacy PID or limit settings interfere with the new process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length supported for motor connections?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor unshielded cables, the limit is typically 50 meters, while shielded cables (required for EMC compliance) should not exceed 25-50 meters without an output filter to prevent high-frequency voltage spikes from damaging the motor insulation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Shielding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure compliance with industrial emission standards, use shielded motor cables. The shield must be connected to the metal backplate of the cabinet using a high-frequency decoupling clamp. Avoid \"pigtails\" at the ground terminal, as they act as antennas for high-frequency noise that can interfere with sensitive PLC signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall high-speed semiconductor fuses or a dedicated motor circuit breaker upstream of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e195N2198\u003c\/strong\u003e. This protects the drive's internal IGBTs from catastrophic failure in the event of a short circuit on the motor side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn installations with multiple drives, consider the total harmonic distortion (THD). If the transformer is near capacity, adding an external AC line reactor can significantly improve the power factor and reduce the heat load on the input transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418461035,"sku":"195N2198","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/195n2198-b2zrwtqkoex.png?v=1776137089","url":"https:\/\/www.plcprotech.com\/products\/vlt-2975-vlt2975pt4b20-danfoss-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}