{"product_id":"vm600-mpc4-200-510-071-113-vibro-meter-machinery-protection-card","title":"VM600 MPC4 200-510-071-113 Vibro-Meter Machinery Protection Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600 MPC4 (200-510-071-113)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the central processing powerhouse for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter VM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emachinery protection system. This high-performance card is engineered to monitor critical rotating assets—such as industrial turbines, centrifugal compressors, and generators—providing four intensive vibration channels and two dedicated speed channels. By performing real-time signal processing and logic evaluation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4 200-510-071-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures millisecond-level response times for emergency shutdowns, effectively preventing catastrophic mechanical failure and protecting high-value capital equipment in power plants and oil refineries worldwide.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-510-071-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is a versatile version of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e, specifically designed for integration with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput\/output card within a VM600 rack.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt processes signals from various sensor types, including proximity probes (TSI), accelerometers, and velocity sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-board Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card features a dedicated processor for performing FFT analysis and tracking integrated vibration levels. It includes programmable alarm limits (Alert and Danger) for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVME Bus Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt utilizes the VME bus for communication with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack controller while maintaining autonomous protection capabilities; even if the rack controller fails, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinues to execute its safety functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports redundant power supply inputs and can be configured in \"Voting Logic\" (e.g., 2-out-of-3) to eliminate false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMPC4 200-510-071-113\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (Dynamic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Channels (Tachometer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 W (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6U Height (Standard VME)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle a \"Hardware Failure\" LED on the MPC4 front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA red LED usually indicates a self-test failure or a configuration mismatch. First, verify the firmware compatibility with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPS (Machinery Protection System)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. If the error persists after a rack power cycle, check the backplane pins for any physical deformation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the MPC4 200-510-071-113 be hot-swapped while the rack is live?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the VM600 rack supports the insertion of cards, it is highly recommended to bypass the associated trip relays before removing or inserting the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent accidental machinery shutdown caused by transient signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this card support SIL (Safety Integrity Level) applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries is designed for use in safety-related systems and is often certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements when configured according to the official safety manual.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOC4T Pairing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4 200-510-071-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis correctly aligned with its corresponding\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Input\/Output) card in the rear of the rack. The communication between these two cards is established through the specialized P2 connector on the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor high-vibration environments, the sensor cable shields must be grounded at the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block only. Avoid multiple ground points to prevent ground loops, which can introduce \"ghost\" vibrations into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessing logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways engage the hardware \"Security Switch\" on the card after uploading the final configuration. This prevents unauthorized remote modifications to the alarm setpoints via the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform is distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDual-Path Architecture\u003c\/strong\u003e, which separates the protection functions from the condition monitoring data. This ensures that the primary safety mission—tripping the machine during a surge—is never compromised by heavy data processing loads. Furthermore, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-510-071-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel features high-resolution A\/D converters that provide superior signal-to-noise ratios, allowing for the detection of subtle bearing wear long before traditional sensors would trigger an alert.\u003c\/p\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695216226667,"sku":"VM600 MPC4 200-510-071-113","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-vm600-mpc4-200-510-071-113-machinery-protection-card-qirg1ha3sqa_c1cf0986-2d60-4647-82ca-84531dce418f.jpg?v=1766130945","url":"https:\/\/www.plcprotech.com\/products\/vm600-mpc4-200-510-071-113-vibro-meter-machinery-protection-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}