{"product_id":"weidmuller-1469510000-pro-eco-480w-24v-20a-pro-eco-switch-mode-power-supply-unit","title":"Weidmuller 1469510000 PRO ECO 480W 24V 20A PRO eco Switch-Mode Power Supply Unit","description":"\u003ch1\u003eWeidmuller 1469510000 PRO ECO 480W 24V 20A PRO eco Switch-Mode Power Supply Unit\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEfficient power delivery in decentralized industrial automation systems is critical, and the \u003cstrong\u003eWeidmuller 1469510000\u003c\/strong\u003e switch-mode power supply unit is engineered to meet this demand. Operating within the PRO eco series, this robust power supply delivers a regulated 24 V DC output with up to 20 A of continuous current, translating to a nominal output power of 480 W. It features a wide-range AC input (85 to 264 V AC) and DC input (80 to 370 V DC) capability, making it highly adaptable to varying global grid conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe compact, corrosion-resistant metal housing is optimized for space-constrained control cabinets, mounting directly onto standard TS 35 DIN rails. With an energy efficiency rating of 91%, the unit minimizes thermal dissipation, allowing reliable operation in ambient temperatures ranging from -25 degC to 70 degC. Integrated safety features include short-circuit protection, overload protection, over-temperature protection, and reverse voltage protection, ensuring maximum uptime for connected PLC, DCS, and I\/O systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-efficiency power conversion reaching up to 91% to reduce heat generation inside enclosures.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range supporting both AC (85 to 264 V AC) and DC (80 to 370 V DC) operation.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-facing potentiometer for precise voltage drop compensation.\u003c\/li\u003e\n  \u003cli\u003eThree-stage LED diagnostic indicator for real-time visual status monitoring of output voltage and load conditions.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to three units to increase total output capacity or establish redundancy.\u003c\/li\u003e\n  \u003cli\u003eRobust screw connection system ensuring secure, vibration-resistant wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller PRO eco 480W power supply is designed for deployment in demanding industrial environments, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation and distribution control panels.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility automation.\u003c\/li\u003e\n  \u003cli\u003eOil and gas processing plant telemetry and DCS cabinets.\u003c\/li\u003e\n  \u003cli\u003eGeneral machinery manufacturing and factory automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePRO ECO 480W 24V 20A (Order No: 1469510000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4050118275483\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 to 264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 to 370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.37 A @ 230 V AC \/ 5.2 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.55 A @ 370 V DC \/ 4.65 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC +\/- 1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22 to 28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 A @ 55 degC, 15 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e480 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e91%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResidual Ripple \/ Breaking Spikes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 50 mVPP @ 24 V DC, IN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Failure Bridging Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 20 ms @ 230 V AC \/ \u0026gt; 20 ms @ 115 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 W \/ 43 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Permissible Air Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm x 125 mm x 120 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1557 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eStatus Indicator \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunctional Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGreen LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOutput voltage is active and normal (Uoutput \u0026gt; 21.6 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eYellow LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh load warning (Ioutput \u0026gt; 90% IRated typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRed LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFault condition (overload, overtemperature, short-circuit, or Uoutput \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for L, N, and PE connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for positive (+24 V DC) and negative (GND) connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap securely onto a standard TS 35 DIN rail. Ensure the unit is mounted vertically to facilitate natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the unit, and 10 mm on the sides when operating under full load conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately rated copper conductors. Ensure all screw terminals are torqued to the manufacturer's specified limits to prevent contact resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the protective earth (PE) terminal to the local system ground busbar prior to energizing the input power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127645035,"sku":"PRO ECO 480W 24V 20A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469510000-g0v45txmh4l.png?v=1776137076","url":"https:\/\/www.plcprotech.com\/products\/weidmuller-1469510000-pro-eco-480w-24v-20a-pro-eco-switch-mode-power-supply-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}