{"product_id":"weidmuller-1504250000-ie-sw-bl06-1tx-4poe-1sc-basic-line-unmanaged-poe-ethernet-switch","title":"Weidmuller 1504250000 IE-SW-BL06-1TX-4POE-1SC Basic Line Unmanaged PoE Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nIntegrating seamlessly into harsh industrial control architectures, the Weidmuller IE-SW-BL06-1TX-4POE-1SC unmanaged Ethernet switch facilitates robust data transmission and power delivery. This hardware variant, identified by part number 1504250000, features \u003cstrong\u003efour Power over Ethernet (PoE) ports\u003c\/strong\u003e, \u003cstrong\u003eone standard Fast Ethernet copper port\u003c\/strong\u003e, and \u003cstrong\u003eone SC-Duplex multimode fiber-optic port\u003c\/strong\u003e to support extended-distance communication up to 5 km.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eFour IEEE 802.3af\/at compliant PoE ports for simplified field device powering.\u003c\/li\u003e\n  \u003cli\u003eOne 100BaseFX multimode fiber port with SC-Duplex connector for noise-immune long-distance uplinks.\u003c\/li\u003e\n  \u003cli\u003eRedundant dual power inputs (12\/24\/48 V DC) to maximize system uptime.\u003c\/li\u003e\n  \u003cli\u003eIP30-rated aluminum housing designed for space-saving DIN-rail mounting.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with a 2 K MAC address table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eIndustrial IP surveillance and security systems in manufacturing plants.\u003c\/li\u003e\n  \u003cli\u003eWLAN access point integration in warehouse environments.\u003c\/li\u003e\n  \u003cli\u003eDistributed control system (DCS) node networking in water\/wastewater facilities.\u003c\/li\u003e\n  \u003cli\u003eTraffic monitoring and outdoor telemetry stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1504250000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIE-SW-BL06-1TX-4POE-1SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTotal Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e6\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePoE Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCopper Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFiber Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x SC-Duplex Multimode (100BaseFX)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 km (typical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12\/24\/48 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e64.56 A at 48 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x Removable 4-pin terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e768 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 1.00g;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 1 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1+ (Primary Power Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 2 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1- (Primary Power Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 3 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2+ (Redundant Power Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePin 4 (4-Pin Terminal Block)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2- (Redundant Power Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePorts 1 to 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100BaseT(X) RJ45 with PoE Injector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100BaseT(X) RJ45 Standard Copper Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100BaseFX Multimode SC-Duplex Fiber Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IE-SW-BL06 series serves as a direct drop-in replacement for older IE-SW-BL05 series configurations when PoE injection is required at the edge. Ensure that existing power supplies are rated for the total PoE budget (typically 15.4W per port for standard PoE) plus the switch's internal consumption.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen operating at the lower end of the input voltage range (12V or 24V DC), verify that the internal step-up converter can stably deliver the 48V DC required for PoE compliance to connected PDs (Powered Devices). In high-vibration environments, ensure the DIN-rail clip is securely locked and the 4-pin terminal block screws are torqued to 0.5 Nm to prevent intermittent power loss.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAlways use shielded twisted-pair (STP) Cat5e or Cat6 cabling for the copper ports to mitigate electromagnetic interference (EMI) in high-voltage panels. The SC-Duplex fiber port must be cleaned with an approved optical fiber connector cleaner before insertion to prevent signal attenuation over the 5 km maximum run.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003e\n    CRITICAL WARNING: De-energize all power sources before attempting installation, wiring, or maintenance. Ensure the redundant power supply lines are completely isolated. Failure to follow these protocols can result in electrical shock, equipment damage, or unexpected system downtime.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the switch onto a standard TS 35 DIN rail, ensuring the top hook catches the rail first, then press down until the latch snaps into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground screw on the aluminum housing to the local protective earth (PE) system using a minimum 14 AWG wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant power sources to the removable 4-pin terminal block, verifying correct polarity for V1 and V2 inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the terminal block into the switch socket and secure the retention screws.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the RJ45 copper cables and the SC-Duplex multimode fiber optic cable to their respective ports.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123254123,"sku":"IE-SW-BL06-1TX-4POE-1SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-1tx-4poe-1sc-tvtmcarvlvx.png?v=1776137753","url":"https:\/\/www.plcprotech.com\/products\/weidmuller-1504250000-ie-sw-bl06-1tx-4poe-1sc-basic-line-unmanaged-poe-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}