{"product_id":"weidmuller-1504290000-ie-sw-bl06t-1tx-4poe-1st-basic-line-unmanaged-poe-switch","title":"Weidmuller 1504290000 IE-SW-BL06T-1TX-4POE-1ST Basic Line Unmanaged PoE Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nFacilitating robust data transmission and power delivery in demanding industrial environments, the Weidmuller 1504290000 (IE-SW-BL06T-1TX-4POE-1ST) functions as a high-performance, unmanaged Fast Ethernet PoE switch. This unit integrates four Power over Ethernet ports, one standard copper port, and one multimode fiber port with an ST-Duplex connector to bridge long-distance network segments up to 5 kilometers. Housed in a rugged IP30 aluminum enclosure, it is engineered to withstand extreme thermal variations and electrical noise common in industrial automation architectures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnmanaged Plug-and-Play:\u003c\/strong\u003e Operates immediately upon connection without complex software configuration or IP assignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Power over Ethernet:\u003c\/strong\u003e Features 4 dedicated PoE ports to power compatible field devices directly over Ethernet cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptical Fiber Uplink:\u003c\/strong\u003e Equipped with 1 multimode ST-Duplex port supporting transmission distances up to 5 km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual 12\/24\/48 V DC inputs ensure continuous network uptime in the event of a primary power supply failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Enclosure:\u003c\/strong\u003e Compact IP30-rated aluminum housing designed for space-constrained DIN-rail or panel mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial manufacturing and assembly line control networks.\u003c\/li\u003e\n  \u003cli\u003eIP-based video surveillance and security systems in harsh outdoor environments.\u003c\/li\u003e\n  \u003cli\u003ePower over Ethernet device integration including sensors, RFID readers, and wireless access points.\u003c\/li\u003e\n  \u003cli\u003eLong-distance fiber optic uplinks in municipal infrastructure and water treatment facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504290000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06T-1TX-4POE-1ST\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransceiver Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMultimode\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eST-Duplex\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Distance (Typical)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12\/24\/48 V DC (2 redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e64.56 A at 48 V DC (0.1 to 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e768 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eData Switching Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStore and Forward\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHumidity Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 mm x 114 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eConnector \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eType\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePorts 1 to 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100BaseT(X) Fast Ethernet with PoE Power Delivery\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePort 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStandard 10\/100BaseT(X) Fast Ethernet Copper Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePort 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eST-Duplex\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100BaseFX Multimode Fiber Optic Port (up to 5 km)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4-pin terminal block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRemovable connector for redundant DC power supply inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IE-SW-BL06T series serves as a direct drop-in replacement for older Weidmuller Basic Line unmanaged switches when migrating to PoE-enabled field architectures. Because this is an unmanaged Layer 2 device, it does not require firmware configuration or software updates, ensuring seamless compatibility across all standard Ethernet protocols and industrial automation networks.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen operating at full PoE capacity, ensure the upstream power supply is rated to handle the combined power budget of all connected PDs (Powered Devices) plus the switch's internal consumption. In enclosed control cabinets with high ambient temperatures, maintain a minimum of 20 mm clearance on both sides to facilitate natural convection and prevent thermal shutdown.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAlways utilize high-quality shielded twisted-pair (STP) cabling for the copper RJ45 ports to minimize electromagnetic interference (EMI) in high-voltage environments. Ensure the functional ground terminal on the 4-pin removable block is connected directly to a low-impedance earth ground to protect the internal transceiver circuitry from transient voltage surges.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before attempting installation, wiring, or maintenance. Failure to isolate power can result in severe electrical shock, equipment damage, or unexpected system operation. Verify that the input voltage matches the device specifications before powering on.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the switch securely onto a standard TS 35 DIN rail, ensuring the locking mechanism snaps firmly into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground terminal on the removable 4-pin block to the local protective earth system.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant DC power supplies to the terminal block, verifying correct polarity (V+\/V-) before inserting the block into the switch.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 network cables into ports 1 through 5, and connect the ST-Duplex fiber optic cable to port 6.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125384043,"sku":"IE-SW-BL06T-1TX-4POE-1ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06t-1tx-4poe-1st-vhn1dpxxrhl.png?v=1776137757","url":"https:\/\/www.plcprotech.com\/products\/weidmuller-1504290000-ie-sw-bl06t-1tx-4poe-1st-basic-line-unmanaged-poe-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}