{"product_id":"woodward-8200-1302-505d-digital-governor-steam-turbine-control","title":"Woodward 8200-1302 505D Digital Governor Steam Turbine Control","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8200-1302\u003c\/strong\u003e is a \u003cstrong\u003e505D (LV-ATX \u0026amp; Marine)\u003c\/strong\u003e digital governor steam turbine control unit engineered for speed regulation, control, and protection of steam turbines in industrial and marine applications. Operating on low-voltage DC power, the \u003cstrong\u003e8200-1302\u003c\/strong\u003e delivers microprocessor-based control for industrial steam turbines driving generators, pumps, or compressors.\u003c\/p\u003e\n\u003cp\u003ePer Woodward Product Change Notification 07004 (September 2024), part number \u003cstrong\u003e8200-1302\u003c\/strong\u003e has been superseded by replacement part number \u003cstrong\u003e8200-2302\u003c\/strong\u003e. The \u003cstrong\u003e8200-1302\u003c\/strong\u003e unit features marine type approvals (Lloyd's Register and DNV-GL) and is rated for skid- or cab-mounted random vibration (RV1 profile). The replacement model \u003cstrong\u003e8200-2302\u003c\/strong\u003e incorporates updated internal relays and is rated for control room applications (RV5 profile).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDigital governor steam turbine controller engineered for industrial and marine turbine applications.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs configured for speed regulation, trip control, and status indication.\u003c\/li\u003e\n\u003cli\u003eLow-voltage ATX (LV-ATX) hardware configuration for specialized industrial and marine power environments.\u003c\/li\u003e\n\u003cli\u003eRated for cab or skid mounting under random vibration profile RV1 (MIL-STD 202F, SAE J1455 Cab Data).\u003c\/li\u003e\n\u003cli\u003eForm, fit, and functional compatibility with replacement item number 8200-2302.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine speed and load regulation\u003c\/li\u003e\n\u003cli\u003eMarine steam turbine driver control\u003c\/li\u003e\n\u003cli\u003eIndustrial generator-drive steam turbine control\u003c\/li\u003e\n\u003cli\u003eMechanical-drive steam turbines for pumps and process compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eReplaced Item Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReplaced Item Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReplacement Item Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReplacement Item Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8200-1302\u003c\/td\u003e\n\u003ctd\u003e505D (LV-ATX \u0026amp; MARINE) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003ctd\u003e8200-2302\u003c\/td\u003e\n\u003ctd\u003e505D (LV-ATX) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8200-1304\u003c\/td\u003e\n\u003ctd\u003eVANTAGE GC (LV-ATX \u0026amp; MARINE) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003ctd\u003e8200-2304\u003c\/td\u003e\n\u003ctd\u003eVANTAGE GC (LV-ATX) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8200-1312\u003c\/td\u003e\n\u003ctd\u003e505XT (LV-ATX \u0026amp; MARINE) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003ctd\u003e8200-2312\u003c\/td\u003e\n\u003ctd\u003e505XT (LV-ATX) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8200-1314\u003c\/td\u003e\n\u003ctd\u003eVANTAGE XC (LV-ATX \u0026amp; MARINE) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003ctd\u003e8200-2314\u003c\/td\u003e\n\u003ctd\u003eVANTAGE XC (LV-ATX) STEAM TURBINE CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%; height: 392.045px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 30.1809%; height: 19.6023px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 66.8233%; height: 19.6023px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 19.6023px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 19.6023px;\"\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 19.6023px;\"\u003eReplaced Part Number\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 19.6023px;\"\u003e8200-1302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eReplacement Part Number\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003e8200-2302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 19.6023px;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 19.6023px;\"\u003e505D Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 19.6023px;\"\u003eControl Type\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 19.6023px;\"\u003eDigital Governor Steam Turbine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 19.6023px;\"\u003eHardware Variant\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 19.6023px;\"\u003eLow Voltage (LV-ATX \u0026amp; Marine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eVibration Grade (8200-1302)\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003eRV1 Cab or Skid Mounted (MIL-STD 202F, M214A, TC(B), SAE J1455 Cab Data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eVibration Limits (8200-1302)\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003e0.04 G^2\/Hz (10 to 2000 Hz), 8.2 Grms, 1.5 hours per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eVibration Grade (8200-2302)\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003eRV5 Control Room (MIL-STD 810F, M514.5A, Cat. 4, Fig. 514.5-C1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eVibration Limits (8200-2302)\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003e0.015 G^2\/Hz (10 to 500 Hz), 1.04 Grms, 2 hours per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eMarine Approvals (8200-1302)\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003eLloyd's Register (LR), DNV-GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 30.1809%; height: 39.2045px;\"\u003eProduct Change Notice\u003c\/td\u003e\n\u003ctd style=\"width: 66.8233%; height: 39.2045px;\"\u003ePCN 07004 (Rev - September 2024)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify installation environment requirements: model 8200-1302 is rated for RV1 cab or skid mounting, while replacement model 8200-2302 is rated for RV5 control room environments.\u003c\/li\u003e\n\u003cli\u003eWhen transitioning from 8200-1302 to replacement model 8200-2302, ensure class-specific marine society approval is not mandatory for the targeted vessel or facility.\u003c\/li\u003e\n\u003cli\u003eWire low-voltage power connections and I\/O signals in accordance with official manufacturer schematics and terminal diagrams.\u003c\/li\u003e\n\u003cli\u003eStandard electrostatic discharge (ESD) protective procedures must be observed during handling and installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarine Type Approvals (8200-1302): Lloyd's Register (LR), DNV-GL\u003c\/li\u003e\n\u003cli\u003eVibration Standards (8200-1302): MIL-STD 202F Method 214A, SAE J1455 Cab Data\u003c\/li\u003e\n\u003cli\u003eVibration Standards (8200-2302): MIL-STD 810F Method 514.5A Category 4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53592463016299,"sku":"8200-1302","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8200-1302.jpg?v=1784727121","url":"https:\/\/www.plcprotech.com\/products\/woodward-8200-1302-505d-digital-governor-steam-turbine-control","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}