{"product_id":"woodward-8200-1311-505-xt-digital-control","title":"Woodward 8200-1311 505-XT Digital Control","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8200-1311 505-XT\u003c\/strong\u003e digital governor is a field-programmable steam turbine control system designed for single valve, split-range, extraction, or admission steam turbines in mechanical drive or generator applications. The \u003cstrong\u003e8200-1311\u003c\/strong\u003e operates as a standalone unit or interfaces with a plant Distributed Control System (DCS) to manage steam turbine operation and parameter limiting. The device controls speed, load, inlet pressure, extraction\/admission pressure, auxiliary parameters, exhaust pressure, and acceleration using integrated PID loops. Operating on AC or DC input power, this control system utilizes a built-in graphical user interface (GUI) with an integrated screen and keypad for system setup, online adjustment, and process parameter monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 8.4-inch LCD graphical display (800x600) and operator keypad\u003c\/li\u003e\n\u003cli\u003eIntegrated PID controllers for Speed, Cascade, Auxiliary, Inlet, Extraction\/Admission, Exhaust, and Acceleration\u003c\/li\u003e\n\u003cli\u003eDual Speed\/Load dynamics with automatic PID optimization tuning\u003c\/li\u003e\n\u003cli\u003eAuto Start Sequence for warm and cold turbine startup procedures\u003c\/li\u003e\n\u003cli\u003eCritical Speed Avoidance with up to three configurable speed bands\u003c\/li\u003e\n\u003cli\u003eFirst-Out Trip and Alarm indication with sequence-of-events time stamping\u003c\/li\u003e\n\u003cli\u003eDynamic operational capability with ratio limiter control for extraction\/admission steam maps\u003c\/li\u003e\n\u003cli\u003eField-configurable input and output options supporting standard 4-20 mA and discrete signal types\u003c\/li\u003e\n\u003cli\u003eIntegrated distributed I\/O expansion via Woodward LinkNet nodes over CAN networks\u003c\/li\u003e\n\u003cli\u003eModbus communication capabilities over Ethernet (TCP\/UDP) and serial (RS-232\/RS-485) links\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle valve steam turbines\u003c\/li\u003e\n\u003cli\u003eSplit-range steam turbine actuators\u003c\/li\u003e\n\u003cli\u003eControlled extraction steam turbines\u003c\/li\u003e\n\u003cli\u003eControlled admission steam turbines\u003c\/li\u003e\n\u003cli\u003eExtraction and admission steam turbines\u003c\/li\u003e\n\u003cli\u003eGenerator drive applications\u003c\/li\u003e\n\u003cli\u003eMechanical drive applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8200-1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88-264 Vac \/ 90-150 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45-65 Hz (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e73 W max, 1.6 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e73 W max, 0.8 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Holdup Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 30 ms @ 110 Vac, \u0026gt; 120 ms @ 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation to EARTH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation to Other Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 3000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (Rear), IP54 (Front bezel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels (MPU: 1 to 35 Vrms, 10 Hz to 35 kHz; PROX: 0 to 32 Vdc, 0.04 Hz to 35 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Sensor Power Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc ± 14%, 0-200 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 channels (4-20 mA, 16-bit resolution, differential\/loop-powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Power Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc ± 14%, 0-250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 channels (4-20 mA, 14-bit resolution, 0 to 600 ohm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels (configurable 4-20 mA or 20-200 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 channels (with contact power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 channels (Form-C, 1 Dedicated Trip, 7 Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ports (10\/100 Mbit\/sec, isolated RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ports (isolated, up to 1 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 port (RS-232 \/ RS-485 isolated, COM1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Pin 1\u003c\/td\u003e\n\u003ctd\u003eL+ Input Power (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Pin 2\u003c\/td\u003e\n\u003ctd\u003eL- Input Power (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Pin 3\u003c\/td\u003e\n\u003ctd\u003eEARTH Ground \/ Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 1\u003c\/td\u003e\n\u003ctd\u003eRS-232 Transmit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 2\u003c\/td\u003e\n\u003ctd\u003eRS-232 Receive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 3\u003c\/td\u003e\n\u003ctd\u003eSignal Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 4\u003c\/td\u003e\n\u003ctd\u003eShield (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 5\u003c\/td\u003e\n\u003ctd\u003eRS-485 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 6\u003c\/td\u003e\n\u003ctd\u003eTermination Resistor (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 7\u003c\/td\u003e\n\u003ctd\u003eTermination Resistor (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 Pin 8\u003c\/td\u003e\n\u003ctd\u003eRS-485 (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed #1 Pin 1-2\u003c\/td\u003e\n\u003ctd\u003eMPU #1 Input Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed #1 Pin 3-4\u003c\/td\u003e\n\u003ctd\u003ePROX #1 Input Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed #1 Pin 5-6\u003c\/td\u003e\n\u003ctd\u003ePROX Power #1 (+24 Vdc \/ GND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed #2 Pin 9-10\u003c\/td\u003e\n\u003ctd\u003eMPU #2 Input Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed #2 Pin 11-12\u003c\/td\u003e\n\u003ctd\u003ePROX #2 Input Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed #2 Pin 13-14\u003c\/td\u003e\n\u003ctd\u003ePROX Power #2 (+24 Vdc \/ GND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Mount the unit vertically so that ventilation slots remain unobstructed at the top and bottom. Ensure surrounding ambient air temperature inside the enclosure does not exceed 70 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the Protective Earth (PE) terminal directly to PE ground using a wire gauge equal to or larger than 4 mm2 (12 AWG) with a properly sized ring lug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Use fixed field wiring suitable for operating temperatures at least 10 degC above the maximum surrounding ambient air temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use double-shielded (SSTP) Cat5 cables for Ethernet links (maximum cable length 100 meters). CAN cabling must use shielded twisted-pair wire with unshielded wire exposure limited to less than 3.8 cm (1.5 inches) at terminal connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Device:\u003c\/strong\u003e Install an easily accessible emergency switch or circuit breaker near the controller to disconnect power. The disconnect device must not interrupt the Protective Earth conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Line Fuses:\u003c\/strong\u003e Utilize external circuit breakers or power-line fusing rated to a minimum of 3.5 A to protect power supply network wiring from short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53643541807467,"sku":"8200-1311","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8200-1311.jpg?v=1785585303","url":"https:\/\/www.plcprotech.com\/products\/woodward-8200-1311-505-xt-digital-control","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}