{"product_id":"yokogawa-adm51c-2-centum-vp-contact-output-module","title":"Yokogawa ADM51C-2 CENTUM VP Contact Output Module","description":"\u003cp\u003eYokogawa \u003cstrong\u003eADM51C-2\u003c\/strong\u003e is a 16-point connector-type digital output module designed for process control and field output interface execution. The \u003cstrong\u003eADM51C-2\u003c\/strong\u003e operates within CENTUM system I\/O module nests to deliver reliable switching signals via transistor contacts to field devices. This module incorporates hold action functionality during on-line maintenance at status output mode to preserve field output integrity.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital output points with connector-style field connections\u003c\/li\u003e\n\u003cli\u003eTransistor contact outputs rated up to 30 V DC at 100 mA\u003c\/li\u003e\n\u003cli\u003eSupports multiple functional output modes: status output, pulse type output, pulse width output, and time proportional ON\/OFF\u003c\/li\u003e\n\u003cli\u003eIntegrated hold action output mode during on-line maintenance for suffix code -2\u003c\/li\u003e\n\u003cli\u003eSignal isolation provided across each individual point\u003c\/li\u003e\n\u003cli\u003eDedicated signal connections via standard KS2 or KS3 cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess automation discrete control loops\u003c\/li\u003e\n\u003cli\u003eField actuator and solenoid control\u003c\/li\u003e\n\u003cli\u003eInterlocking and status indication systems\u003c\/li\u003e\n\u003cli\u003eSequential output timing and pulse modulation tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSuffix Codes\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM51C\u003c\/td\u003e\n\u003ctd\u003e       -2\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eContact Output Module (16 Points, Connector Type), \u003c\/p\u003e\n\u003cp\u003eHold action when On-line maintenance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM51C-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output\u003c\/td\u003e\n\u003ctd\u003eNumber of I\/O Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output\u003c\/td\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eTransistor contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003eResistive load\/Inductive load: 30 V DC, 100 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA or less (5.0 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003ePulse Width\u003c\/td\u003e\n\u003ctd\u003e0.1 to 7200 s (Setting at time of pulse-type, pulse width mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctionality\u003c\/td\u003e\n\u003ctd\u003eOutput Modes\u003c\/td\u003e\n\u003ctd\u003eStatus output, Pulse type output, Pulse width output, Time proportional ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctionality\u003c\/td\u003e\n\u003ctd\u003eOn-Line Maintenance Action\u003c\/td\u003e\n\u003ctd\u003eHold action (-2 suffix code, output held at status output mode only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Protection\u003c\/td\u003e\n\u003ctd\u003eCPU \/ Bus Detection Mode\u003c\/td\u003e\n\u003ctd\u003eDetection time or output mode can be set when selecting abnormal detection mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eEach point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eInstalled in the I\/O module nest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSignal Connection\u003c\/td\u003e\n\u003ctd\u003eKS2 or KS3 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e Install the module directly into a compatible I\/O module nest (such as AMN32) within the system rack or cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connection:\u003c\/strong\u003e Utilize standard KS2 or KS3 cables to establish connections between the connector module and terminal interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Restrictions:\u003c\/strong\u003e When using time-proportioning ON\/OFF output mode in an AMN32 nest, two modules can be installed in Slots 1 and 3. If installing only one module in this mode, general ADMC modules can be placed in Slots 3 and 4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Slots:\u003c\/strong\u003e Install T9081CV dummy plates on vacant backboard connector slots within AMN3 nests to protect connectors against environmental corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e Non-Incendive (NI) compliant with CSA Standards for Class I, Division 2, Groups A, B, C, and D T4 when installed in an approved cabinet with an ANS50\/AND50 Node Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Standards:\u003c\/strong\u003e CSA Standard C22.2-No.157-92, CSA Standard C22.2-No.213-M1987\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISA Standard:\u003c\/strong\u003e ISA Standard ISA S12.12 1994\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53665693991275,"sku":"ADM51C-2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ADM51C-2_001_1200x1200_aa004bfd-274b-4f40-aa03-4e1b7df42e03.jpg?v=1785902404","url":"https:\/\/www.plcprotech.com\/products\/yokogawa-adm51c-2-centum-vp-contact-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}