{"product_id":"yokogawa-adv142-p10-s1-centum-vp-ac-digital-input-module","title":"Yokogawa ADV142-P10 S1 CENTUM VP AC Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142-P10 (ADV142)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-voltage 16-channel digital input module purpose-built for the Yokogawa CENTUM VP distributed control system (DCS). Engineered to interface with 200 V to 240 V AC field signals, this module provides robust status monitoring for heavy-duty industrial equipment such as large motor starters, power distribution breakers, and high-voltage actuators. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated pushbutton input functionality, allowing it to accurately count pulse edges for manual operator interfaces. With a focus on process continuity, the module supports dual-redundant configurations, ensuring that critical safety and status data remain available even in the event of a hardware failure. Its high withstanding voltage and group-based isolation make it an essential component for power plants and heavy manufacturing facilities where electrical noise and high-voltage transients are prevalent.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe suffix codes for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142-P10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefine its specific functional and environmental configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes the specialized pushbutton input function, enabling the module to detect and count pushbutton edges with a dedicated minimum detection time of 200 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the module as a General-purpose type, suitable for standard industrial environments without specialized explosion protection requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the Basic type hardware revision, providing the essential input processing logic and connectivity for the FIO subsystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eS1:\u003c\/b\u003e Designated as a standard type with specific hardware revision optimizations for CENTUM VP integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eADV142-P10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16, isolated (8 channels per common)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 240 V AC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput ON Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 V AC (226 V Peak) to 264 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput OFF Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 V AC (56 V Peak) or less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Response Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 ms or less (status input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Current Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mA (at 5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure clamp terminal or AKB333 cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the critical wiring requirement for AC inputs sharing the same common?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen multiple AC input signals are connected to the same common terminal (grouped every 8 channels), they must be on the same phase. Mixing phases on a single common minus (-) side can cause hardware damage and unpredictable signal behavior.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the input current for the ADV142 compare to lower voltage modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for higher voltage thresholds; it typically draws 6.2 mA per channel at 240 V\/60 Hz. This higher current draw ensures a stable \"ON\" state and improves noise immunity in environments with high electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between status input and pushbutton input response?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard status inputs have a response time of 160 ms for state detection. However, when utilizing the pushbutton function, the module requires a minimum ON detection time of 200 ms and can handle a maximum ON\/OFF cycle of 2.5 Hz to ensure pulse accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates at potentials up to 264 V AC. During installation or maintenance, ensure that all field-side power is locked out before accessing the pressure clamp terminals. Use insulated tools and verify that the terminal cover is securely fastened to prevent accidental contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 2 kV AC isolation between the input signal and the system logic, and 1.35 kV AC between commons. When wiring the 16 channels, ensure the two 8-channel groups are logically separated if they represent different power segments of the plant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC input modules generate more heat than DC equivalents due to higher power dissipation per channel. Ensure the CENTUM VP node unit has at least 50 mm of clearance for airflow. If installing multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules in a single rack, monitor cabinet temperatures to ensure they do not exceed the 70 deg C limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor high-density wiring, use the Yokogawa AKB333 dedicated cable. This cable is specifically rated for the 220 V AC signals processed by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e, providing the necessary insulation thickness and shielding to maintain signal integrity over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695400022379,"sku":"ADV142-P10 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-adv142-p10-s1-digital-input-module-gvpjb4pkp3l_5ec4ef07-246f-432c-8186-342e3f9961c1.jpg?v=1766133677","url":"https:\/\/www.plcprotech.com\/products\/yokogawa-adv142-p10-s1-centum-vp-ac-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}