{"product_id":"yokogawa-afv30d-a41152-centum-vp-duplexed-field-control-unit","title":"Yokogawa AFV30D-A41152 CENTUM VP Duplexed Field Control Unit","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV30D-A41152\u003c\/strong\u003e is a 19-inch rack-mountable Duplexed Field Control Unit (FCU) designed for CENTUM VP control systems. Serving as the core execution unit for Field Control Station (FCS) operations, this unit houses dual-redundant power supplies and processor modules to maintain continuous, high-reliability control performance. The \u003cstrong\u003eAFV30D-A41152\u003c\/strong\u003e processes field signals through up to 8 I\/O modules and connects with up to 13 ESB bus and optical ESB bus node units (ANB10\/ANB11). Communication across system networks is handled via dual-redundant Vnet\/IP interfaces using CAT5e or better UTP cabling connected to Layer 2 switches. Main memory protection during power loss is supported through an integrated battery backup system.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-redundant Vnet\/IP network communication interfaces\u003c\/li\u003e\n\u003cli\u003eDual-redundant power supply module architecture\u003c\/li\u003e\n\u003cli\u003eDual-redundant processor module configuration using identical CP471 modules\u003c\/li\u003e\n\u003cli\u003eSupport for up to 8 I\/O modules within the local unit\u003c\/li\u003e\n\u003cli\u003eInterfacing capacity for up to 13 ESB bus and optical ESB bus node units\u003c\/li\u003e\n\u003cli\u003eBattery backup maintaining main memory for up to 72 hours during power failure\u003c\/li\u003e\n\u003cli\u003eBuilt-in READY contact output for hardware failure detection\u003c\/li\u003e\n\u003cli\u003eStandard 19-inch rack-mountable physical housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control System (DCS) process control in industrial plants\u003c\/li\u003e\n\u003cli\u003eHigh-availability process control requiring redundant processing and power architecture\u003c\/li\u003e\n\u003cli\u003eLarge-scale field I\/O expansion via ESB and optical ESB bus node units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFV30D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit (for Vnet\/IP and FIO, 19-inch Rack Mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type (for CP471)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP, dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways 2 (R6.01 or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFV30D-A41152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mounting (Rack mount M5x8 screws, insulation bush)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 VA (at 100-120 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Backup for Main Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Recharge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin. 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREADY Contact Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 terminals (NC, C), 30 V DC, max. 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Module Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (2x CP471)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Module Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (2 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal I\/O Module Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable Node Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 13 \/ FCU (total of ANB10 and ANB11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLFS1700 Control function for field control station (R6.01 or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265.9 mm x 482.6 mm x 207 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREADY Contact Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection (NC, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP cable (CAT5e or better) connection to Layer 2 switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots 7 and 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eESB Bus Coupler Module (EC401 or EC402) for ESB bus node connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots 1 to 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptical ESB Bus Repeater Master Modules (ANT401 or ANT411) installed from right to left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the unit inside a 19-inch rack using eight M5x8 screws and the included insulating bushes.\u003c\/li\u003e\n\u003cli\u003eEnsure the unit is mounted in a keyed metallic cabinet to fulfill safety and EMC standards.\u003c\/li\u003e\n\u003cli\u003eConnect power, ground, and READY contact output wiring using M4 screw terminals.\u003c\/li\u003e\n\u003cli\u003eConnect the dual-redundant Vnet\/IP network using CAT5e or higher category UTP cable connected to an external Layer 2 switch.\u003c\/li\u003e\n\u003cli\u003eTo connect ESB bus node units in a dual-redundant configuration, install ESB Bus Coupler Modules (EC401 or EC402) into both slot 7 and slot 8.\u003c\/li\u003e\n\u003cli\u003eFor optical ESB bus links, populate Optical ESB Bus Repeater Master Modules (ANT401 or ANT411) sequentially in slots 1 through 6 from right to left.\u003c\/li\u003e\n\u003cli\u003eWhen installing I\/O modules with built-in barriers, fit the insulating partition kit (Part No. T9083ND).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53644182913387,"sku":"AFV30D-A41152","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AFV30D-A41252.jpg?v=1785586354","url":"https:\/\/www.plcprotech.com\/products\/yokogawa-afv30d-a41152-centum-vp-duplexed-field-control-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}