{"product_id":"yokogawa-afv30d-a41252-centum-vp-duplexed-field-control-unit","title":"Yokogawa AFV30D-A41252 CENTUM VP Duplexed Field Control Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV30D-A41252\u003c\/strong\u003e is a 19-inch rack-mountable duplexed Field Control Unit (FCU) designed for CENTUM VP systems using Vnet\/IP and FIO. As the core of the control function in a Field Control Station (FCS), the \u003cstrong\u003eAFV30D-A41252\u003c\/strong\u003e features dual-redundant power supply modules (PW482) and dual-redundant processor modules (CP471) to ensure high system availability. The unit provides dual-redundant Vnet\/IP network communications and supports memory protection during power outages. It accommodates up to 8 I\/O modules and manages process control operations within integrated automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-redundant processor module configuration (CP471)\u003c\/li\u003e\n\u003cli\u003eDual-redundant power supply module configuration (PW482)\u003c\/li\u003e\n\u003cli\u003eDual-redundant Vnet\/IP communication interface\u003c\/li\u003e\n\u003cli\u003eBattery backup for main memory during power failures\u003c\/li\u003e\n\u003cli\u003eSupport for up to 13 connectable node units (ESB Bus Node Units ANB10 and Optical ESB Bus Node Units ANB11 combined)\u003c\/li\u003e\n\u003cli\u003eIntegrated READY contact output for hardware status signaling\u003c\/li\u003e\n\u003cli\u003eStandard 19-inch rack-mountable physical design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCENTUM VP Integrated Production Control Systems\u003c\/li\u003e\n\u003cli\u003eDistributed Control Systems (DCS) for process control\u003c\/li\u003e\n\u003cli\u003eField Control Station (FCS) central processing and I\/O execution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFV30D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit (for Vnet\/IP and FIO, 19-inch Rack Mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type (for CP471)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP, dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways 2 (R6.01 or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFV30D-A41252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Memory Battery Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Recharge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin. 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREADY Contact Output Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC, max. 0.3 A (Terminals: NC, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x CP471 (Dual-redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x PW482 (Dual-redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. I\/O Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable Node Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 13 per FCU (ANB10 \/ ANB11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack Mounting (M5x8 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265.9 mm x 482.6 mm x 207 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREADY Contact Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork (Vnet\/IP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP cable (CAT5e or better) to Layer 2 switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESB Bus Coupler (Slots 7 \u0026amp; 8)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlot 7 and Slot 8 for EC401 \/ EC402 modules (Dual-redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical ESB Bus Repeater (Slots 1 to 6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANT401 or ANT411 master modules installed from right to left in pairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Requirement:\u003c\/strong\u003e To meet safety and EMC standards, the unit must be installed in a keyed metallic cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Secure to a standard 19-inch rack using M5x8 screws and the included insulating bushes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESB Bus Couplers:\u003c\/strong\u003e For dual-redundant processor configurations, install ESB Bus Coupler Modules (EC401 or EC402) in both slot 7 and slot 8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Repeater Installation:\u003c\/strong\u003e Install pairs of ANT401 or ANT411 modules in slots 1 to 6 from right to left according to branch requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBarrier Insulation:\u003c\/strong\u003e If modules with built-in barriers are installed, an insulating partition kit (Part No. T9083ND) must be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Spare Parts \u0026amp; Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/yokogawa-cp471-00-centum-vp-processor-module\"\u003eYokogawa CP471-00 CENTUM VP Processor Module\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/yokogawa-pw481-50-centum-vp-power-supply-module\"\u003eYokogawa PW481-50 Power Supply Module\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53643798217067,"sku":"AFV30D-A41252","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AFV30D-A41252.jpg?v=1785586354","url":"https:\/\/www.plcprotech.com\/products\/yokogawa-afv30d-a41252-centum-vp-duplexed-field-control-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}