{"product_id":"yokogawa-nfai135-s51-s2-stardom-fcn-analog-input-module","title":"Yokogawa NFAI135-S51 S2 STARDOM-FCN Analog Input Module","description":"\u003ch3 data-path-to-node=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003eYokogawa NFAI135-S51 S2\u003c\/b\u003e is an isolated channel analog input module engineered for the STARDOM FCN autonomous controller platform. It features 8 dedicated input channels configured to process 4 to 20 mA DC current signals from 2-wire and 4-wire transmitters. Channel-to-channel isolation delivers robust electrical protection and high signal integrity, effectively mitigating ground loops and field noise in complex industrial processing zones. Equipped with an ISA Standard G3 environmental option, the module is built to withstand corrosive atmosphere variables, making it optimal for long-term reliability in critical process automation frameworks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eChannel-to-Channel Isolation\u003c\/b\u003e: Employs rigorous electrical isolation between the inputs and the system, as well as between individual channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHART Communication Capability\u003c\/b\u003e: Supports digital field communication overlaid onto standard 4 to 20 mA hardware loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eISA Standard G3 Option\u003c\/b\u003e: Configured with professional environmental protection to counter atmospheric corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eIntegrated Overcurrent Protection\u003c\/b\u003e: Protects sensitive internal circuits against unexpected electrical surges from field line paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003eOil and gas exploration and refining facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003ePetrochemical and chemical process plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003eMunicipal water and wastewater management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003ePower generation system monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003eDistributed industrial data acquisition networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003eNFAI135\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,2,0\"\u003eAnalog Input Module (4 to 20mA, 8-channel, Isolated channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003e-S\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,2,0\"\u003eStandard type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,2,0\"\u003eWith no explosion protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,2,0\"\u003eWith ISA Standard G3 option\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eNFAI135\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003eNumber of Input Channels\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003e8-channel input, isolated channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eInput Signal\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eAllowable Input Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003e25 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003eOvercurrent Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003eProvided\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eWithstanding Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"10,7,1,0\"\u003eBetween input\/output and system: 500 V AC for 1 minute\u003c\/p\u003e\n\u003cbr data-path-to-node=\"10,7,1,1\"\u003e\n\u003cp data-path-to-node=\"10,7,1,2\"\u003eBetween channels: 500 V AC for 1 minute\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eInput Resistance (Power ON)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e250 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eInput Resistance (Power OFF)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e500 ohm or more\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eAccuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e+\/-0.1% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,0,0\"\u003e\u003cb data-path-to-node=\"10,11,0,0\" data-index-in-node=\"0\"\u003eData Refresh Cycle\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,1,0\"\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003e\u003cb data-path-to-node=\"10,12,0,0\" data-index-in-node=\"0\"\u003eInput Step Response Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003e100 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,0,0\"\u003e\u003cb data-path-to-node=\"10,13,0,0\" data-index-in-node=\"0\"\u003eTransmitter Power Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,1,0\"\u003e20.2 to 29.3 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,14,0,0\"\u003e\u003cb data-path-to-node=\"10,14,0,0\" data-index-in-node=\"0\"\u003eTemperature Drift\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,14,1,0\"\u003eMax. +\/-0.01%\/degC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,15,0,0\"\u003e\u003cb data-path-to-node=\"10,15,0,0\" data-index-in-node=\"0\"\u003eMaximum Current Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,15,1,0\"\u003e360 mA (5 V DC), 450 mA (24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,16,0,0\"\u003e\u003cb data-path-to-node=\"10,16,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,16,1,0\"\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,17,0,0\"\u003e\u003cb data-path-to-node=\"10,17,0,0\" data-index-in-node=\"0\"\u003eExternal Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,17,1,0\"\u003ePressure clamp terminal, MIL connector cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,18,0,0\"\u003e\u003cb data-path-to-node=\"10,18,0,0\" data-index-in-node=\"0\"\u003eHART Communication\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,18,1,0\"\u003eAvailable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003eEnsure a stable 24 V DC source is linked to the analog field power supply terminal of the power supply module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003eForm physical terminations using the corresponding pressure clamp terminal block or a tailored MIL connector cable system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003eNote that when using a MIL connector cable like the KMS40, the withstanding voltage limit between input and system drops to 500 V AC for 1 minute.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003eAvoid coupling Zener barriers to this hardware; specify an isolation barrier for intrinsically safe installation demands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695390028139,"sku":"NFAI135-S51 S2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-nfai135-s51-s2-1-autonomous-controller-zdbfkxsgrmp.jpg?v=1766055404","url":"https:\/\/www.plcprotech.com\/products\/yokogawa-nfai135-s51-s2-stardom-fcn-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}