{"product_id":"yokogawa-sdv144-s33-centum-vp-digital-input-module","title":"Yokogawa SDV144-S33 Centum VP Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSDV144-S33 (SDV144-S33)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Module designed for the Yokogawa Centum VP integrated production control system and the ProSafe-RS safety instrumented system (SIS).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1082 citation-end-1082\"\u003eFeaturing 16 channels of isolated inputs, this module is a critical component for monitoring field switch statuses, valve positions, and emergency stop signals in high-integrity industries such as LNG terminals, petrochemical plants, and offshore oil platforms.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe \"S33\" suffix indicates a specific hardware revision and coating specification, ensuring the module meets the rigorous\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 (Safety Integrity Level 3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements. Its primary value lies in its ultra-reliable diagnostic capabilities, ensuring that the control system can distinguish between a normal process state and a field wiring fault, thereby preventing nuisance trips and maximizing plant uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-1081 citation-end-1081\"\u003eThe SDV144-S33 architecture is built around hardware redundancy and comprehensive self-diagnostics.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1080 citation-end-1080\"\u003eEach of the 16 channels is galvanically isolated to prevent electrical noise from the field from propagating to the system bus.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports \"Line Monitoring,\" which allows the system to detect open circuits or short circuits in the field wiring when used with external end-of-line (EOL) resistors.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1079 citation-end-1079\"\u003eThis module is typically installed in an FIO (Field network I\/O) node unit and communicates via the ESB or ER bus, providing high-speed status updates to the Safety Control Station (SCS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSDV144-S33\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCentum VP \/ ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (16-Channel, Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Integrity Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 mA (at 24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.0 x 4.0 x 13.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFIO Node Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"S\" and \"33\" in the suffix signify?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S\" generally denotes a standard type with specific hardware features for safety systems, while \"33\" refers to the style code or revision. In Yokogawa's ecosystem, style codes are vital for ensuring compatibility with existing backplanes and software versions (Revision 3.3).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SDV144-S33 be used in a non-safety (DCS) application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it is primarily a ProSafe-RS (SIS) module, Yokogawa hardware is often cross-compatible within the FIO architecture. However, using a SIL3-rated module for standard DCS functions is generally not cost-effective unless standardized spares are required across the facility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support pulse counting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SDV144 is optimized for state detection (On\/Off). For high-speed pulse counting or frequency measurement, Yokogawa offers dedicated pulse input modules (like the SET401) with specialized high-speed processing circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Monitoring Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf using the SDV144-S33 for safety-critical loops, ensure that the \"Line Monitoring\" function is enabled in the software. This requires the installation of a 10 kOhm parallel resistor and a 1 kOhm series resistor at the field device. Without these, the module cannot detect a wire break, which may compromise the SIL3 rating of the loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports \"Online Replacement.\" When replacing a faulty unit, ensure the new module's style code (S33) matches the one defined in the system project. Inserting a different style code may cause a configuration mismatch fault in the Safety Control Station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-quality ferruled connections for the pressure-clamp terminals. Given the 16-channel density, ensure that the common (negative) returns are properly balanced to avoid voltage drops that could lead to false \"Off\" states in long-distance cable runs (exceeding 200 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695394255211,"sku":"SDV144-S33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-sdv144-s33-digital-input-module-lcwrqzjvfmk_7fc665bc-c975-497c-b2e0-4910e590d988.jpg?v=1766133213","url":"https:\/\/www.plcprotech.com\/products\/yokogawa-sdv144-s33-centum-vp-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}