{"title":"Schneider Electric","description":"\u003cp\u003eA Schneider Electric é líder global em transformação digital, gestão de energia e automação industrial. A arquitetura da marca integra a plataforma EcoStruxure, unindo sistemas \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/schneider-modicon-quantum\"\u003eModicon PLC\u003c\/a\u003e, \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/schneider-altivar-process\"\u003edrives Altivar\u003c\/a\u003e e soluções especializadas de segurança \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/triconex\"\u003eTriconex\u003c\/a\u003e. As principais características técnicas incluem protocolos de comunicação abertos, alta eficiência energética e hardware habilitado para IoT para manufatura inteligente. Funcionalmente, as soluções Schneider oferecem controle abrangente desde máquinas discretas até infraestrutura em grande escala e data centers. Ao combinar hardware confiável com insights baseados em dados, os componentes da Schneider Electric garantem máxima disponibilidade operacional, sustentabilidade e segurança nos setores globais de mineração, químico e energia.\u003c\/p\u003e","products":[{"product_id":"modicon-pc-e984-685-984-685-slot-mount-controller-cpu-ps","title":"Controlador CPU\/PS para Montagem em Slot MODICON PC-E984-685 (984-685)","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon PC-E984-685 (984-685)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um Controlador Lógico Programável (CLP) de alto desempenho, montado em slot, que integra uma Unidade Central de Processamento (CPU) e uma Fonte de Alimentação (PS) em um único módulo. Parte da série legada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon 984\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, o E984-685 foi projetado para tarefas de automação industrial de médio a grande porte que exigem processamento lógico robusto e comunicação I\/O de alta velocidade. Essa arquitetura \"Tudo em Um\" simplifica o planejamento do sistema ao fornecer energia interna para a CPU e o backplane, enquanto suporta a I\/O padrão da Série 800 da Modicon. Sua capacidade dupla AC\/DC (entrada de 115\/220 VAC e saída de 24 VDC) o torna uma solução versátil para sistemas legados em manufatura e controle de processos.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhes)\u003c\/h3\u003e\n\u003cp\u003eA arquitetura\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé projetada para execução determinística e gerenciamento de memória de alta densidade.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFonte de Alimentação Integrada:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo possui uma fonte de alimentação embutida que aceita\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e115 VAC ou 220 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(selecionável por jumper\/chave). Ela fornece os\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee tensões lógicas necessárias para alimentar a CPU e até um número específico de módulos I\/O no rack local.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento de Memória:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipado com memória de alta capacidade para lógica (Relay Ladder Logic) e RAM de estado. Suporta RAM CMOS com bateria para garantir a retenção do programa durante quedas de energia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePortas de Comunicação Duplas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNormalmente possui duas portas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus (RS-232\/RS-485)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, permitindo conexão simultânea a um terminal de programação (como um P190 ou software baseado em PC) e a uma interface homem-máquina (IHM) ou sistema SCADA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Executivo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO controlador utiliza um cartucho \"Executivo\" intercambiável ou firmware baseado em FLASH que define o conjunto de instruções e protocolos de comunicação, permitindo atualizações em campo para aprimorar a funcionalidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModicon (Schneider Electric)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEUA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 \/ 220 VAC (47 - 63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSaída Interna\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Para I\/O local e lógica)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemória Lógica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8K a 16K (dependendo do modelo)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacidade I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAté 1024 Discretos \/ 1024 Registradores\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMontagem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMontagem em Slot da Série 984\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackup de Bateria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBateria de lítio para retenção da RAM CMOS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo limpar um código de erro \"CPU Parada\" no E984-685?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUma CPU parada é frequentemente indicada por padrões específicos de LED (por exemplo, LED \"Pronto\" apagado). Verifique os códigos de erro usando os softwares Modsoft ou Concept. Causas comuns incluem bateria descarregada, erros de paridade de memória ou incompatibilidade de I\/O na configuração.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso usar a saída de 24 VDC para alimentar dispositivos externos de campo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmbora o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eforneça 24 VDC para a lógica interna do rack e módulos locais da série 800, é prática padrão de engenharia usar uma fonte de alimentação externa dedicada para cargas pesadas de campo (solenóides, contatores) para evitar que ruídos elétricos reiniciem a CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a função do interruptor de alternância \"Modo Configuração\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO interruptor permite ao usuário proteger a memória (Executar\/Proteger) ou colocar a CPU em estado de configuração para atribuição de endereço da porta Modbus e ajuste da taxa de transmissão.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper de Seleção de Tensão:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCRÍTICO:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAntes de ligar a energia, verifique se o jumper interno de seleção de tensão está configurado corretamente para a rede local (115 VAC ou 220 VAC). Aplicar 220 VAC em uma unidade configurada para 115 VAC causará falha imediata do estágio da fonte de alimentação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento e Redução de Ruído:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssegure que o rack do CLP esteja aterrado por meio de uma trança de cobre robusta a um ponto central de aterramento \"Estrela\". Use cabos trançados blindados para comunicações Modbus para evitar interferência eletromagnética (EMI) de motores de alta potência que possam corromper o fluxo de dados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManutenção da Bateria:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSubstitua a bateria de lítio a cada 2-3 anos enquanto a unidade estiver\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eligada\u003c\/strong\u003e. Se a bateria for removida com a unidade desligada, o programa do usuário e a configuração serão perdidos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ese destaca pela sua\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEstabilidade do Conjunto de Instruções\u003c\/strong\u003e. Diferente dos controladores modernos que requerem atualizações frequentes de firmware, o 984-685 oferece um ambiente lógico industrial \"congelado\" altamente previsível. Sua fonte de alimentação integrada reduz a área física do sistema CLP, tornando-o uma escolha ideal para projetos de \"Retrofit no Local\" onde o espaço no gabinete é limitado, mas ainda é necessária a lógica Modicon de alta velocidade.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695205937515,"sku":"MODICON PC-E984-685","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/modicon-pc-e984-685-model-685e-cpu-module-sj0s4kwb3qd_2b2d3c30-5f5c-4a2d-8ad5-07d46c4a0687.jpg?v=1766130685"},{"product_id":"schneider-electric-140cpu67060-modicon-quantum-unity-hot-standby-processor","title":"Schneider Electric 140CPU67060 Processador Hot Standby Modicon Quantum Unity","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eEste \u003cstrong\u003eprocessador Unity\u003c\/strong\u003e é projetado para a \u003cstrong\u003eplataforma de automação Modicon Quantum\u003c\/strong\u003e para fornecer controle de alta disponibilidade por meio da funcionalidade \u003cstrong\u003eHot Standby\u003c\/strong\u003e. Operando a uma frequência de clock de \u003cstrong\u003e266 MHz\u003c\/strong\u003e, o módulo possui uma memória onboard de \u003cstrong\u003e512 KB\u003c\/strong\u003e dedicada para RAM de dados, com suporte para expansão de armazenamento de programas e arquivos via cartões PCMCIA.\u003c\/p\u003e\n\u003cp\u003eO processador facilita a distribuição robusta do sistema, gerenciando até \u003cstrong\u003e63 estações de E\/S distribuídas\u003c\/strong\u003e e até \u003cstrong\u003e6 racks remotos de E\/S Ethernet X80 (racks suportando até 6 drops)\u003c\/strong\u003e. Configurações locais de E\/S discretas e analógicas são explicitamente restritas em configurações Hot Standby para preservar a integridade da arquitetura do sistema. As capacidades integradas de comunicação apresentam múltiplos tipos de conexão, incluindo uma \u003cstrong\u003eporta dedicada de fibra óptica multimodo\u003c\/strong\u003e que utiliza o protocolo Hot Standby, além de portas dedicadas para conexões \u003cstrong\u003eModbus\u003c\/strong\u003e, \u003cstrong\u003eModbus Plus\u003c\/strong\u003e e \u003cstrong\u003eUSB\u003c\/strong\u003e. É otimizado para controle de processo de alta confiabilidade e verificações automatizadas.\u003c\/p\u003e\n\u003ch3\u003eCaracterísticas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlta Disponibilidade com Hot Standby\u003c\/strong\u003e: Conta com uma interface integrada de fibra óptica multimodo MT-RJ que executa um protocolo dedicado de Hot Standby para sincronizar controladores primário e secundário.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArquitetura de Memória Escalável\u003c\/strong\u003e: Oferece 512 KB de RAM interna para dados, com capacidade de expansão até 8 MB para armazenamento de arquivos e 7168 kB para programas de aplicação usando cartões PCMCIA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExecução em Alta Velocidade\u003c\/strong\u003e: Realiza operações com tempo de execução de 0,0525...0,075 µs para instruções Booleanas e 0,4...0,5 µs para cálculos de ponto flutuante.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpla Gama de Redes\u003c\/strong\u003e: Suporta até 3 redes locais para Modbus Plus, Ethernet TCP\/IP e Profibus DP, além de mapeamento remoto e distribuído AS-Interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibilidade Flexível com Rack\u003c\/strong\u003e: Projetado para operar dentro das estruturas padrão de montagem Modicon Quantum, alinhando-se com configurações de sistema de 2 a 16 slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGerenciamento de Tarefas Dedicado\u003c\/strong\u003e: Formatado para executar 1 tarefa mestre cíclica\/ periódica, otimizado especificamente para requisitos de ambiente de processo determinístico.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSistemas redundantes de controle de usinas de energia\u003c\/li\u003e\n\u003cli\u003eProcessamento químico e petroquímico contínuo\u003c\/li\u003e\n\u003cli\u003eInstalações de tratamento de água e esgoto com alta disponibilidade\u003c\/li\u003e\n\u003cli\u003eInfraestrutura crítica e monitoramento ambiental\u003c\/li\u003e\n\u003cli\u003eInstalações industriais distribuídas de E\/S em grande escala\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategoria do Parâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro de Especificação Técnica\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValor \/ Detalhes\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFabricante\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinha de Produto\u003c\/td\u003e\n\u003ctd\u003ePlataforma de automação Modicon Quantum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesempenho\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequência do Clock\u003c\/td\u003e\n\u003ctd\u003e266 MHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTempo de Execução (Booleano)\u003c\/td\u003e\n\u003ctd\u003e0,0525...0,075 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTempo de Execução (Palavra)\u003c\/td\u003e\n\u003ctd\u003e0,045...0,06 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTempo de Execução (Ponto Fixo)\u003c\/td\u003e\n\u003ctd\u003e0,045...0,06 μs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTempo de Execução (Ponto Flutuante)\u003c\/td\u003e\n\u003ctd\u003e0,4...0,5 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNúmero de Instruções por ms\u003c\/td\u003e\n\u003ctd\u003e20 Kinst\/ms (100% Booleano) \/ 15 Kinst\/ms (65% Booleano, 35% numérico) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSobrecarga do Sistema\u003c\/td\u003e\n\u003ctd\u003eTarefa mestre de 1 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemória\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDescrição da RAM Interna\u003c\/td\u003e\n\u003ctd\u003e512 KB para dados \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMemória de Programa Expansível\u003c\/td\u003e\n\u003ctd\u003eAté 7168 kB com cartão PCMCIA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eArmazenamento de Arquivos Expansível\u003c\/td\u003e\n\u003ctd\u003eAté 8 MB com cartão PCMCIA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFunção do Interruptor\u003c\/td\u003e\n\u003ctd\u003ePorta de memória com chave liga\/desliga \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacidade \u0026amp; Roteamento\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNúmero de Slots\u003c\/td\u003e\n\u003ctd\u003e10, 16, 2, 4, 6 (dependente do rack) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNúmero de Racks\u003c\/td\u003e\n\u003ctd\u003e2 racks locais \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEstações de E\/S Distribuídas\u003c\/td\u003e\n\u003ctd\u003e63 estação(ões) 1 rack(s) - 3 rede(s) Modbus Plus \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEstações de E\/S Remotas\u003c\/td\u003e\n\u003ctd\u003e6-2 racks remotos ethernet X80 (Até 6 drops X80) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLimites de E\/S Discretas \/ Analógicas\u003c\/td\u003e\n\u003ctd\u003e0-local (proibido em aplicação Hot Standby) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCapacidade de E\/S Distribuída\u003c\/td\u003e\n\u003ctd\u003e8000 entradas, 8000 saídas \/ 500 entradas, 500 saídas por rede Modbus Plus \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eE\/S Específicas para Aplicação\u003c\/td\u003e\n\u003ctd\u003eCarimbo de tempo preciso, Contador, Entradas de interrupção de alta velocidade, Link serial \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElétrico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequisito de Corrente do Barramento\u003c\/td\u003e\n\u003ctd\u003e2500 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnóstico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSinalização Local\u003c\/td\u003e\n\u003ctd\u003e1 LED vermelho para colisão Ethernet \/ 1 LED verde para atividade Ethernet (COM) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMecânico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDimensões (Racks Suportados)\u003c\/td\u003e\n\u003ctd\u003eAltura de 290 mm; largura variando de 104 mm a 671 mm com base em configurações de 2 a 16 slots \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTipo de Interface \/ Conector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConector MT-RJ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 porta de fibra óptica multimodo operando com protocolo Hot Standby para interconexão PLC primário\/secundário de até 4 km \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConector RJ45\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 porta de conexão dedicada para comunicação de barramento Modbus \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConector SUB-D 9 Fêmea\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 porta de conexão dedicada para interface de rede Modbus Plus \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorta USB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTipo de conexão integrada para acesso local de diagnóstico e programação \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterconexão de Redundância do Sistema\u003c\/strong\u003e: Conecte os processadores primário e secundário usando cabeamento padrão de fibra óptica multimodo MT-RJ. A arquitetura suporta um comprimento físico máximo de até 4 km entre os controladores pareados.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestrições de Rack\u003c\/strong\u003e: Instale o processador com segurança em um slot compatível da plataforma de automação Modicon Quantum. Observe que tarefas auxiliares, tarefas de interrupção de temporizador, tarefas de interrupção padrão, tarefas de interrupção de E\/S e tarefas rápidas periódicas são explicitamente proibidas ao executar uma configuração de aplicação Hot Standby.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção de Memória\u003c\/strong\u003e: Utilize a chave de hardware funcional a bordo para ativar ou desativar a porta de memória, protegendo os blocos de dados e programas configurados contra modificações locais não autorizadas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegregação de Rede\u003c\/strong\u003e: Garanta o término adequado na linha de rede Modbus Plus SUB-D 9 e monitore os LEDs de diagnóstico para evitar colisões de comunicação ou perdas de pacotes em caminhos locais.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformidade e Certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertificações do Produto\u003c\/strong\u003e: CE, CSA, GOST, UL, Diversos (Marítimo) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormas\u003c\/strong\u003e: HazLoc \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSustentabilidade \u0026amp; Diretrizes\u003c\/strong\u003e: Produto Green Premium, conforme RoHS (desde o código de data 1111 via declaração de conformidade da Schneider Electric), referência REACH sem SVHC acima do limite designado \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerguntas Frequentes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a finalidade da porta de fibra óptica localizada neste módulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA interface de fibra óptica multimodo MT-RJ é dedicada para executar o protocolo integrado Hot Standby, sincronizando processadores primário e secundário em distâncias de até 4 km para backup contínuo do controle de processo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCartões de E\/S locais são permitidos no mesmo rack que o processador durante operação redundante?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. Configurações locais de E\/S discretas e analógicas são proibidas quando o processador é implementado dentro de uma topologia de sistema Hot Standby. Toda E\/S deve ser roteada através de redes distribuídas ou conexões remotas Ethernet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComo a memória do programa é expandida se os 512 KB de RAM de dados forem insuficientes para aplicações completas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO módulo suporta expansão de memória de hardware via cartões PCMCIA, suportando até 7168 kB para armazenamento de programas e até 8 MB para armazenamento geral de arquivos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eO que os LEDs de diagnóstico integrados na faceplate indicam?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA faceplate inclui dois indicadores de status LED distintos: um LED vermelho que alerta o operador sobre uma colisão ativa de Ethernet e um LED verde que indica atividade contínua de comunicação Ethernet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695219798379,"sku":"140CPU67060","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-140cpu67060-cpu-single-slot-module-o0yn4ma0whp_5466774c-a84c-465c-b79c-6cff29a3bf2f.jpg?v=1766131065"},{"product_id":"ace949-2-schneider-electric-rs485-2-wire-interface-for-sepam-series","title":"Interface RS485 2 Fios para Série Sepam Schneider Electric ACE949-2","description":"\u003ch2\u003eVisão Geral do Produto\u003c\/h2\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric ACE949-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserve como a ponte crítica de comunicação para a linha de relés de proteção Sepam, incluindo as Séries 20, 40, 60 e 80. Como uma interface RS485 2 fios de alto desempenho, este módulo permite a integração perfeita das unidades de proteção em uma rede Modbus RTU (S-LAN ou E-LAN). Em ambientes complexos de distribuição de energia, o ACE949-2 garante transmissão de dados em tempo real e monitoramento remoto dos parâmetros elétricos. Seu design compacto, montado em trilho DIN, permite que os engenheiros ampliem as capacidades de comunicação dos sistemas de automação de subestações sem sacrificar espaço no painel. Ao facilitar conectividade robusta de 2 fios, o módulo oferece uma solução econômica e confiável para telemetria industrial de longa distância.\u003c\/p\u003e\n\u003ch2\u003ePrincipais Vantagens Técnicas\u003c\/h2\u003e\n\u003ch3\u003eVersatilidade de Duplo Protocolo\u003c\/h3\u003e\n\u003cp\u003eA arquitetura do ACE949-2 suporta configurações S-LAN (Rede Local do Sistema) e E-LAN (Rede Local de Engenharia). Essa flexibilidade permite que o módulo funcione simultaneamente como ferramenta de relatório para sistemas SCADA e como porta dedicada para engenharia remota e configuração de parâmetros via software.\u003c\/p\u003e\n\u003ch3\u003eGerenciamento Otimizado de Energia\u003c\/h3\u003e\n\u003cp\u003eProjetado para eficiência industrial, o módulo opera em uma ampla faixa de tensão de 12 V DC a 24 V DC. Possui gerenciamento inteligente do consumo de energia, consumindo apenas 16 mA no modo de recepção e atingindo pico de 40 mA durante a transmissão ativa de dados, garantindo carga térmica mínima dentro do gabinete.\u003c\/p\u003e\n\u003ch3\u003eResiliência de Grau Industrial\u003c\/h3\u003e\n\u003cp\u003eA Schneider projetou o ACE949-2 para suportar as condições rigorosas de ambientes de subestações. O hardware atende aos rigorosos padrões IEC 60255-21 para vibração, choque e atividade sísmica (Nível 2), garantindo que o link de comunicação permaneça intacto mesmo durante distúrbios mecânicos ou eventos sísmicos.\u003c\/p\u003e\n\u003ch3\u003eDiagnóstico Avançado de Sinal\u003c\/h3\u003e\n\u003cp\u003eUm indicador LED frontal fornece feedback visual instantâneo sobre a atividade do link. Esta ferramenta de diagnóstico em nível de hardware permite que a equipe de manutenção verifique o status da comunicação rapidamente, reduzindo significativamente o tempo de solução de problemas durante a comissionamento ou falhas na rede.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEspecificações Técnicas\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNome do Modelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACE949-2 (Ref: 59642)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibilidade\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSérie Sepam 20, 40, 48, 60, 80, 80 NPP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface de Rede\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485 - 2 fios\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocolo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU (E-LAN ou S-LAN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão Nominal de Alimentação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 V DC \/ 24 V DC (+\/- 10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMontagem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrilho DIN Simétrico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C a 70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensões\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88 mm (A) x 72 mm (L) x 30 mm (P)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRobustez Sísmica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Gn (Horizontal), 1 Gn (Vertical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGuia de Instalação\u003c\/h2\u003e\n\u003ch3\u003eDistância de Comunicação e Calibração de Tensão\u003c\/h3\u003e\n\u003cp\u003eO desempenho do cabo varia conforme a tensão de alimentação e o número de dispositivos conectados. Para máxima confiabilidade, siga as seguintes restrições de distância:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFonte de 24 V DC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuporta até 1000m para 5 dispositivos, ou 375m para 25 dispositivos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlimentação 12 V DC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuporta até 320m para 5 dispositivos, ou 125m para 25 dispositivos.\u003c\/p\u003e\n\u003cp\u003eSempre use cabos de par trançado blindado para minimizar interferência eletromagnética.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAterramento e Blindagem\u003c\/h3\u003e\n\u003cp\u003eO ACE949-2 requer uma conexão de aterramento dedicada para manter a integridade do sinal. Use o terminal tipo parafuso para uma trança de cobre estanhado (6…100 mm²) ou um cabo padrão (2,5…50 mm²). Certifique-se de que o comprimento do fio de terra permaneça abaixo de 0,2 metros e seja apertado com torque de 2,2 N.m.\u003c\/p\u003e\n\u003ch3\u003eLógica de Montagem\u003c\/h3\u003e\n\u003cp\u003eInstale o módulo em um trilho DIN simétrico dentro do mesmo cubículo que o relé Sepam. Mantenha espaço adequado ao redor da unidade para permitir a dissipação de calor, mesmo que a unidade tenha baixo consumo de energia.\u003c\/p\u003e\n\u003ch2\u003eVantagens de Engenharia\u003c\/h2\u003e\n\u003cp\u003eO ACE949-2 é o padrão da indústria para garantir a longevidade dos esquemas de proteção baseados em Sepam. Sua principal vantagem está na \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompatibilidade Eletromagnética (EMC)\u003c\/strong\u003e; ele é testado contra ondas oscilantes amortecidas de 2,5 kV e transientes rápidos de 4 kV, tornando-o virtualmente imune ao ruído elétrico comum em ambientes de equipamentos de alta tensão. Embora a Schneider tenha anunciado uma descontinuação futura (dez 2026), o ACE949-2 continua sendo a peça sobressalente essencial \"plug-and-play\" para a infraestrutura existente, garantindo que sistemas legados permaneçam totalmente comunicativos e em conformidade com os protocolos de segurança até 2030 e além.\u003c\/p\u003e\n\u003ch2\u003ePerguntas Técnicas Frequentes\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: \u003c\/strong\u003eA ficha técnica menciona que o ACE949-2 será descontinuado em breve. Ainda devo comprá-lo?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1: \u003c\/strong\u003eSim. A Schneider Electric comprometeu-se a oferecer suporte \"End-of-Service\" até 31 de dezembro de 2030. Para instalações existentes da Série Sepam, o ACE949-2 é a substituição OEM exata necessária para manter a integridade do sistema sem precisar reengenheirar toda a arquitetura de comunicação.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Posso usar o ACE949-2 para uma rede RS485 de 4 fios?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2: \u003c\/strong\u003eNão. O ACE949-2 é projetado especificamente para redes RS485 de 2 fios. Se seu sistema requer uma configuração de 4 fios, você deve escolher o módulo de interface apropriado de 4 fios (como o ACE950) para garantir a compatibilidade do protocolo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Como a tensão de alimentação afeta o comprimento da minha rede?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e A tensão de alimentação é diretamente proporcional à distância permitida do cabo. Utilizar uma fonte de alimentação de 24 V DC quase triplica o alcance efetivo em comparação com uma fonte de 12 V DC (por exemplo, 750m vs 180m para 10 dispositivos), o que é crítico para plantas industriais de grande escala.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: \u003c\/strong\u003eQual é o significado do LED na face frontal?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4: \u003c\/strong\u003eO LED fornece monitoramento em tempo real da atividade do link. Um LED piscando confirma que a sondagem Modbus RTU foi bem-sucedida, permitindo a identificação rápida se uma falha de comunicação é devido a hardware\/fiação ou configuração de software.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403626859,"sku":"ACE949-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-ace949-2-interface-module-rloiqethywk_8637d61d-5e9f-48eb-b40d-3872696a404a.jpg?v=1766133922"},{"product_id":"schneider-atv61hd22n4z-variable-speed-drive","title":"Inversor de Frequência Schneider ATV61HD22N4Z","description":"\u003cp\u003eO \u003cstrong\u003eSchneider Electric ATV61HD22N4Z\u003c\/strong\u003e é um inversor de frequência (VFD) de alto desempenho da série \u003cstrong\u003eAltivar 61\u003c\/strong\u003e. Esta série foi especificamente projetada para aplicações de torque variável, tornando-se um padrão consagrado para o controle de bombas e ventiladores em gestão predial e processos industriais.\u003c\/p\u003e\n\u003cp\u003eO sufixo \"Z\" normalmente indica uma versão fornecida sem o choke DC, frequentemente usada em configurações específicas de montagem em painéis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategoria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar 61 (ATV61)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePotência do Motor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 kW \/ 30 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 a 480 V CA (3 fases)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente Contínua\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 A (a 4 kHz \/ 400 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente Transitória Máxima\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e52,8 A (por 60 segundos)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequência de Saída\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,1 a 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGrau de Proteção\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Estilo Aberto)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eControle e Comunicação\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLeis de Controle:\u003c\/strong\u003e Escalar (\u003cspan class=\"math-inline\"\u003e$V\/f$\u003c\/span\u003e), Controle Vetorial de Fluxo (sem sensor) e razões especializadas para economia de energia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePortas Integradas:\u003c\/strong\u003e Modbus e CANopen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlots de Opção:\u003c\/strong\u003e Suporta placas de comunicação (Profibus, DeviceNet, Ethernet) e placas de extensão de E\/S.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003ePrincipais Recursos para Aplicações\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOtimização de Energia:\u003c\/strong\u003e Inclui uma lei específica para reduzir perdas do motor em até \u003cstrong\u003e30%\u003c\/strong\u003e em condições de baixa carga.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLógica para Bombas\/Ventiladores:\u003c\/strong\u003e Possui função integrada \"Catch on the Fly\" (reinício de ventilador em movimento), modos de repouso\/ativação e controle multi-bombas (com placa).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegração de Segurança:\u003c\/strong\u003e Oferece terminal \u003cstrong\u003eSafe Torque Off (PWR)\u003c\/strong\u003e para evitar partidas acidentais do motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePersonalização:\u003c\/strong\u003e Macros para funções especializadas como \"Bombear\", \"Ventilação\" ou \"Uso Geral\" facilitam a configuração inicial.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDiretrizes de Instalação e Manutenção\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontagem:\u003c\/strong\u003e Projetado para montagem vertical em um invólucro elétrico. Como é uma unidade \u003cstrong\u003eIP20\u003c\/strong\u003e, deve ser protegida contra poeira e umidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDispersão de Calor:\u003c\/strong\u003e A unidade gera aproximadamente \u003cstrong\u003e685 W\u003c\/strong\u003e de calor em carga total. Garanta que a capacidade do ventilador do painel seja suficiente para manter a temperatura ambiente abaixo de \u003cspan class=\"math-inline\"\u003e$50^\\circ C$\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChoke DC:\u003c\/strong\u003e Observe que a versão \"Z\" pode exigir um reator de linha externo ou choke DC para cumprir os limites de distorção harmônica, dependendo dos requisitos da rede local.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeleção de Cabos:\u003c\/strong\u003e Use cabos de motor blindados para minimizar interferência eletromagnética (EMI). Mantenha a fiação de controle e a de potência em dutos separados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003ePerguntas Frequentes (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePosso usar este inversor para um transportador ou guindaste?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmbora seja possível, não é recomendado. O ATV61 é otimizado para \u003cstrong\u003eTorque Variável\u003c\/strong\u003e (bombas\/ventiladores). Para aplicações de torque constante, como transportadores ou guinchos, a série \u003cstrong\u003eAltivar 71 (ATV71)\u003c\/strong\u003e ou a mais recente \u003cstrong\u003eATV930\u003c\/strong\u003e é mais adequada.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é o modelo substituto do ATV61?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA série Altivar 61 foi amplamente substituída pelo \u003cstrong\u003eAltivar Process ATV630\u003c\/strong\u003e. O ATV630 oferece monitoramento de energia superior e Ethernet embutido como padrão.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo limpar uma falha \"PLF\" (Perda de Fase)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerifique a alimentação de entrada para uma fase caída. Se a entrada estiver correta, inspecione as conexões do barramento DC. Se estiver testando o motor em bancada sem carga, pode ser necessário desativar a verificação de \"Perda de Fase de Saída\" no menu de gerenciamento de falhas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEle suporta controle PID?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. O ATV61 possui um regulador PID embutido para controle de pressão ou fluxo, permitindo ajustar a velocidade do motor com base em um sinal de feedback de um sensor 4-20mA ou 0-10V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403725163,"sku":"ATV61HD22N4Z","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-atv61hd22n4z-variable-speed-drive-ttezyqhr2on_0cb7a1e8-801a-4e60-84af-ea9464b643ec.jpg?v=1766133928"},{"product_id":"schneider-atv630d45n4-variable-speed-drive","title":"Inversor de Frequência Schneider ATV630D45N4","description":"\u003cp\u003eO \u003cstrong\u003eSchneider Electric ATV630D45N4\u003c\/strong\u003e é um inversor de frequência (VSD) de alto desempenho da linha \u003cstrong\u003eAltivar Process ATV600\u003c\/strong\u003e. Projetado especificamente para processos industriais e utilidades, destaca-se no gerenciamento de fluidos (bombas, ventiladores e compressores) oferecendo funções embutidas de gestão de energia e monitoramento de ativos.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEspecificações Técnicas\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategoria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar Process ATV600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePotência do Motor (Uso Normal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 kW \/ 60 cv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePotência do Motor (Uso Pesado)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37 kW \/ 50 cv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 a 480 V CA (3 fases)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente de Linha\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e81,5 A (a 380 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePotência Aparente\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63,9 kVA (a 480 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente de Saída Contínua\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88 A (a 4 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eComunicação \u0026 Controle\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocolos Integrados\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherNet\/IP, Modbus TCP, Modbus Serial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlots de Expansão\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlot A (expansão I\/O), Slot B (módulos de comunicação)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEntradas\/Saídas Digitais\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 DI (STU\/Safe Torque Off), 3 Saídas de Relé\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEntradas\/Saídas Analógicas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 AI (configurável por software), 2 AO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGrau de Proteção\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP21 (Tipo UL 1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003ePrincipais Características\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInteligência Embutida:\u003c\/strong\u003e Apresenta funções \"Stop-and-Go\" para reduzir o consumo de energia em standby e uma ferramenta integrada \"Curva da Bomba\" para otimizar o desempenho hidráulico.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGestão de Ativos:\u003c\/strong\u003e Inclui servidor web embutido e códigos QR dinâmicos para acesso instantâneo a diagnósticos e dados de manutenção via smartphone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegração de Segurança:\u003c\/strong\u003e Vem padrão com \u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e SIL3\/PLe, reduzindo a necessidade de contatores de segurança externos e atendendo aos padrões globais de segurança.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMitigação Harmônica:\u003c\/strong\u003e Choke DC embutido limita a distorção harmônica total (\u003cspan class=\"math-inline\"\u003e$THDi$\u003c\/span\u003e) a menos de 48% sem filtros adicionais.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDiretrizes de Instalação\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRequisitos de Resfriamento:\u003c\/strong\u003e A unidade dissipa aproximadamente \u003cstrong\u003e990 W\u003c\/strong\u003e de calor em carga total. Garanta ventilação adequada no painel e mantenha as distâncias mínimas de afastamento (superior\/inferior\/laterais) especificadas no manual de montagem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiação:\u003c\/strong\u003e Use cabos de motor blindados para cumprir os requisitos de EMC. Garanta que a conexão de terra (PE) esteja segura e siga um esquema de aterramento em estrela para minimizar ruídos elétricos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontagem:\u003c\/strong\u003e O ATV630D45N4 é projetado para montagem em parede ou em painel. Deve ser instalado verticalmente (\u003cspan class=\"math-inline\"\u003e$10^\\circ$\u003c\/span\u003e de tolerância) para garantir a convecção térmica adequada.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção de Entrada:\u003c\/strong\u003e Use fusíveis de alta velocidade ou disjuntor (ex.: Schneider TeSys GV4) dimensionados para a corrente de entrada do inversor para proteção contra curtos-circuitos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerguntas Frequentes (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a diferença entre \"Normal Duty\" e \"Heavy Duty\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNormal Duty (45 kW) é para aplicações com baixa exigência de sobrecarga (até 110% por 60s), como bombas centrífugas. Heavy Duty (37 kW) é para aplicações de alto torque (até 150% por 60s), como transportadores ou bombas de deslocamento positivo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso controlar este inversor via PLC por Ethernet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. As portas duplas Ethernet\/IP e Modbus TCP permitem integração perfeita com PLCs Schneider Modicon ou outros controladores industriais como Rockwell ou Siemens.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO que é a função \"Stop-and-Go\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEsta função coloca automaticamente o inversor em um estado de baixo consumo quando o motor não precisa funcionar, reduzindo o consumo interno em até \u003cstrong\u003e60%\u003c\/strong\u003e durante períodos de inatividade.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO Terminal de Display Gráfico está incluído?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim, os modelos padrão ATV630 incluem um terminal de display gráfico de texto simples removível que suporta diagnóstico multilíngue e backup de parâmetros.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403954539,"sku":"ATV630D45N4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-atv630d45n4-variable-speed-drive-jqwynpsxcww_5e55a8d2-e0a6-4789-873c-b098f556cc51.jpg?v=1766133943"},{"product_id":"schneider-bmxftb2000-modicon-m340-terminal-block","title":"Schneider BMXFTB2000 Modicon M340 Terminal Block","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBMXFTB2000\u003c\/strong\u003e is a 20-pin removable connection block engineered specifically for the \u003cstrong\u003eModicon M340\u003c\/strong\u003e automation platform. This specialized terminal component serves as the central physical interface to bridge discrete or analog field wiring directly to the system's input and output processing modules. By mapping the active sensor and actuator signal lines into a high-density configuration, it enables uninterrupted electrical continuity for complex process manufacturing and machinery control loops.\u003c\/p\u003e\n\u003cp\u003eDesigned for perfect integration within the \u003cstrong\u003eModicon M340\u003c\/strong\u003e hardware ecosystem, this removable cage clamp block simplifies panel wiring and speeds up maintenance routines. It features a standalone plug-in design that permits quick-swapping or card replacement without the need to individually detach, label, or re-terminate field conductors. The robust internal cage clamp contacts exert continuous, uniform tension on bare or ferruled copper wires, ensuring reliable gas-tight connections that withstand structural machine vibration inside industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDeveloped as a dedicated system accessory for the \u003cstrong\u003eModicon M340\u003c\/strong\u003e \/ X80 automation series to guarantee exact structural alignment.\u003c\/li\u003e\n\u003cli\u003eEquipped with a 20 removable cage clamp terminal block layout to streamline heavy-duty field terminations.\u003c\/li\u003e\n\u003cli\u003eNatively accommodates single-conductor wiring profiles with cross-sectional areas from 0.34 mm2 to 1 mm2.\u003c\/li\u003e\n\u003cli\u003eFormulated as a removable connection block to support efficient module servicing and minimize layout repair intervals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField wire termination for \u003cstrong\u003eModicon M340\u003c\/strong\u003e digital inputs, digital outputs, and low-level analog I\/O hardware module lines.\u003c\/li\u003e\n\u003cli\u003eMarshalling and signal distribution within plant control cabinets, local operator stations, and motor control centers (MCC).\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure monitoring networks including municipal wastewater facilities, material conveyor grids, and chemical treatment plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eAll mechanical dimensions, packaging quantities, and material ratings are compiled directly from the official factory engineering documentation:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.823%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 31.9637%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 50.2587%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eCompatibility Range\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eModicon M340 \/ Modicon X80 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eAccessory Type\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eRemovable connection block \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Terminals\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e20 removable cage clamp terminal block \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eAccessory Destination\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eFor module with 20-pin removable terminal block \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eValid Conductor Size\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e1 x 0.34..1 mm2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNet Product Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e0.093 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eUnit Type of Package 1\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003ePCE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Units in Package 1\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Height\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e3.500 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Width\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e4.500 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e11.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e109.000 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eUnit Type of Package 2\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eS02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Units in Package 2\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e60 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Height\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e15.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Width\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e30.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e40.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e6.941 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eUnit Type of Package 3\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eP06 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Units in Package 3\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e960 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Height\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e75.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Width\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e80.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e60.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e119.056 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eContractual Warranty\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e18 months \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Connection:\u003c\/strong\u003e Orient the plug-in block alignment grooves to match the front tracking lip of the \u003cstrong\u003eModicon M340\u003c\/strong\u003e module, then slide inward until the locking tabs snap firmly into the primary module housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Termination:\u003c\/strong\u003e Strip the outer protective jacket of the single-conductor copper cable to the exact depth specified by the installation print before sliding it into the open cage clamp terminal pocket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp Mechanism:\u003c\/strong\u003e Compress the cage clamp internal spring by introducing a flat-head terminal tool, position the bare copper wire into the terminal seat, and withdraw the tool to implement a uniform, continuous-pressure hold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBundle Protection:\u003c\/strong\u003e Bind the incoming field wires using the retention anchors built into the terminal outer frame to eliminate downstream pull forces or twisting stress on individual termination pins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Status:\u003c\/strong\u003e Active pro-active compliance with EU RoHS Directive parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Composition:\u003c\/strong\u003e Completely toxic heavy metal free and mercury free.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegional Directives:\u003c\/strong\u003e Certified under the official China RoHS Declaration framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Notices:\u003c\/strong\u003e California Proposition 65 warning provided regarding potential trace exposure limits for Lead and lead compounds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 20-pin terminal block fit onto 40-pin Modicon M340 high-density modules?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eNo, this component is configured specifically for \u003cstrong\u003eModicon M340\u003c\/strong\u003e modules built with a corresponding 20-pin front interface layout. High-density 40-pin modules require a larger and entirely separate connection block assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this part number include the electronic I\/O module card or only the terminal block?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThis part number represents the standalone 20-pin removable cage clamp terminal block accessory. The central processing units and primary I\/O electronic cards must be acquired separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sizes of field wiring can be reliably clamped into this connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated cage clamps are certified to securely terminate single-conductor copper wire sizes ranging from a minimum of 0.34 mm2 to a maximum of 1 mm2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to pull this terminal assembly away from the M340 module while the rack is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the system allows for the removal and insertion of accessories under power in safe, ordinary locations, all external field-side current loops and voltages must be analyzed first to eliminate hazardous electrical tracking or shocks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104508567915,"sku":"BMXFTB2000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bmxftb2000-w4iwyobv4nz.png?v=1776162982"},{"product_id":"schneider-electric-atv320u55n4b-altivar-machine-atv320-variable-speed-drive","title":"Schneider Electric ATV320U55N4B Altivar Machine ATV320 Variable Speed Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003evariable speed drive\u003c\/strong\u003e is engineered for \u003cstrong\u003ecomplex machines\u003c\/strong\u003e requiring reliable motor control and specialized safety features. Operating within a rated supply voltage range of \u003cstrong\u003e380...500 V\u003c\/strong\u003e alternating current (AC) across \u003cstrong\u003e3 phases\u003c\/strong\u003e, it delivers a nominal output current of \u003cstrong\u003e14.3 A\u003c\/strong\u003e and supporting a motor power of \u003cstrong\u003e5.5 kW\u003c\/strong\u003e designated for \u003cstrong\u003eheavy duty\u003c\/strong\u003e operations.\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates extensive input and output options, featuring \u003cstrong\u003e7 discrete inputs\u003c\/strong\u003e, \u003cstrong\u003e3 discrete outputs\u003c\/strong\u003e, \u003cstrong\u003e3 analogue inputs\u003c\/strong\u003e, and \u003cstrong\u003e1 analogue output\u003c\/strong\u003e. It integrates a \u003cstrong\u003eClass C2 EMC filter\u003c\/strong\u003e and offers embedded communication over \u003cstrong\u003eModbus serial\u003c\/strong\u003e and \u003cstrong\u003eCANopen\u003c\/strong\u003e. For enhanced application compatibility, optional communication modules such as \u003cstrong\u003eEtherCAT\u003c\/strong\u003e, \u003cstrong\u003eProfibus DP V1\u003c\/strong\u003e, \u003cstrong\u003ePROFINET\u003c\/strong\u003e, \u003cstrong\u003eEthernet Powerlink\u003c\/strong\u003e, \u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e, and \u003cstrong\u003eDeviceNet\u003c\/strong\u003e can be utilized. Built-in functional safety capabilities include \u003cstrong\u003eSafe torque off (STO)\u003c\/strong\u003e, \u003cstrong\u003eSafe Stop 1 (SS1)\u003c\/strong\u003e, and \u003cstrong\u003eSafely Limited Speed (SLS)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Control Profiles\u003c\/strong\u003e: Supports multiple asynchronous motor control profiles (Voltage\/Frequency ratios in 2 or 5 points, quadratic U\/f for Energy Saving, and flux vector control without sensor) along with synchronous vector control without sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Safety Capabilities\u003c\/strong\u003e: Embedded with functional safety capabilities, explicitly featuring \u003cstrong\u003eSafe torque off (STO)\u003c\/strong\u003e, \u003cstrong\u003eSafe Stop 1 (SS1)\u003c\/strong\u003e, and \u003cstrong\u003eSafely Limited Speed (SLS)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Torque Performance\u003c\/strong\u003e: Delivers a transient overtorque capacity of \u003cstrong\u003e170...200%\u003c\/strong\u003e of the nominal motor torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Protective Braking\u003c\/strong\u003e: Equipped with an integrated \u003cstrong\u003ebrake chopper\u003c\/strong\u003e and supports braking to standstill via \u003cstrong\u003eDC injection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-Quadrant Operation\u003c\/strong\u003e: Supports full \u003cstrong\u003e4 quadrant operation\u003c\/strong\u003e for driving and braking in both forward and reverse directions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptable Ramp Profiles\u003c\/strong\u003e: Provides customizable acceleration and deceleration ramps including linear, U, S, CUS, ramp switching, automatic stop with DC injection, and ramp adaptation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Slip Compensation\u003c\/strong\u003e: Provides load-independent automatic motor slip compensation, which is adjustable from \u003cstrong\u003e0...300%\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackaging machinery\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveying systems\u003c\/li\u003e\n\u003cli\u003eTextile manufacturing equipment\u003c\/li\u003e\n\u003cli\u003eHoisting and lifting mechanisms\u003c\/li\u003e\n\u003cli\u003eWoodworking and metal processing machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%; height: 3469.72px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 58.8068px;\"\u003e\n\u003cth style=\"width: 24.1035%; height: 58.8068px;\"\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 29.7262%; height: 58.8068px;\"\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 42.0052%; height: 58.8068px;\"\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eFormat of the Drive\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eBook \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e\u003cstrong\u003eElectrical Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eRated Supply Voltage [Us]\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e380...500 V (-15% to +10%) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e50...60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.8068px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 58.8068px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 58.8068px;\"\u003eRelative Symmetric Network Frequency Tolerance\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 58.8068px;\"\u003e5% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eLine Current\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e20.7 A at 380 V \/ 14.5 A at 500 V (heavy duty) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e20.7 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eProspective Line Isc\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e22 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eElectrical Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eMotor Power kW\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e5.5 kW for heavy duty \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e14.3 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eBase Load Current at High Overload\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e14.3 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e500 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eMaximum Output Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e0.599 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eApparent Power\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e12.6 kVA at 500 V (heavy duty) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e2...16 kHz adjustable \/ 4...16 kHz with derating factor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eNominal Switching Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e4 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eDiscrete Input Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e7 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 295.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 295.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 295.597px;\"\u003eDiscrete Input Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 295.597px;\"\u003e\n\u003cp\u003eSTO safe torque off: 24 V DC, 1.5 kOhm\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eDI1...DI6 logic inputs: 24 V DC (max 30 V)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eDI5 programmable as pulse input: 0...30 kHz, 24 V DC (max 30 V) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eDiscrete Input Logic\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003ePositive logic (source) \/ Negative logic (sink) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 165.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 165.597px;\"\u003eDiscrete Output Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 165.597px;\"\u003e\n\u003cp\u003eOpen collector DQ+: 0...1 kHz, 30 V DC, 100 mA\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eOpen collector DQ-: 0...1 kHz, 30 V DC, 100 mA \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAnalogue Input Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 295.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 295.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 295.597px;\"\u003eAnalogue Input Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 295.597px;\"\u003e\n\u003cp\u003eAI1 voltage: 0...10 V DC, 30 kOhm, 10 bits\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eAI2 bipolar differential voltage: +\/- 10 V DC, 30 kOhm, 10 bits\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eAI3 current: 0...20 mA (configurable to 4-20 mA, x-20 mA, 20-x mA), 250 Ohm, 10 bits \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAnalogue Output Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 185.199px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 185.199px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 185.199px;\"\u003eAnalogue Output Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 185.199px;\"\u003e\n\u003cp\u003eSoftware-configurable current AQ1: 0...20 mA, 800 Ohm, 10 bits\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eSoftware-configurable voltage AQ1: 0...10 V DC, 470 Ohm, 10 bits \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 457.585px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 457.585px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 457.585px;\"\u003eRelay Output Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 457.585px;\"\u003e\n\u003cp\u003eConfigurable relay logic R1A: 1 NO (100,000 cycles)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R1B: 1 NC (100,000 cycles)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R1C\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R2A: 1 NO (100,000 cycles)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R2C \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 445.199px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 445.199px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 445.199px;\"\u003eRelay Switching Limits\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 445.199px;\"\u003e\n\u003cp\u003eResistive load (cos phi = 1): 3 A at 250 V AC or 30 V DC (R1A, R1B, R1C)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eInductive load (cos phi = 0.4, L\/R = 7 ms): 2 A at 250 V AC or 30 V DC (all relays)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eResistive load (cos phi = 1): 5 A at 250 V AC or 30 V DC (R2A, R2C)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eMinimum: 5 mA at 24 V DC (all relays) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e\u003cstrong\u003ePerformance \u0026amp; Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eRegulation Loop\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eAdjustable PID regulator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eSpeed Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e+\/- 10% of nominal slip from 0.2 Tn to Tn \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eFan: 195.0 W at 380 V, switching frequency 4 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eMounting Mode\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eWall mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e150 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e308.0 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e232.0 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e4.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eOperating Position\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eVertical +\/- 10 degrees \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eIP20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eEnvironmental Class\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eClass 3C3 and Class 3S2 according to IEC 60721-3-3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eClass 3K5 according to EN 60721-3 \u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eShock Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eMax acceleration: 150 m\/s^2 at 11 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 165.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 165.597px;\"\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 165.597px;\"\u003e\n\u003cp\u003eMax acceleration: 10 m\/s^2 at 13...200 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eMax deflection: 1.5 mm at 2...13 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eCooling Air Volume\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e60 m3\/h \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eIII \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003ePollution Degree\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 145.994px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 145.994px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 145.994px;\"\u003eAmbient Air Temp (Operation)\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 145.994px;\"\u003e\n\u003cp\u003e-10...50 degC without derating\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e50...60 degC with derating factor \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAmbient Air Temp (Storage)\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e-25...70 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAmbient Air Temp (Transport)\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e-25...70 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSTO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafe Torque Off functional safety input (24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDI1...DI4, DI6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital logic inputs (24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDI5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital logic input \/ Programmable pulse input (0...30 kHz, 24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDQ+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen collector discrete output (0...1 kHz, 30 V DC, 100 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDQ-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen collector discrete output (0...1 kHz, 30 V DC, 100 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAI1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue voltage input (0...10 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAI2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBipolar differential analogue voltage input (+\/- 10 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAI3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue current input (0...20 mA \/ 4-20 mA configurable) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAQ1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable analogue output (0...20 mA or 0...10 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Normally Open (NO) contact \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Normally Closed (NC) contact \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR1C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Common terminal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Normally Open (NO) contact \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Common terminal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial \/ CANopen integrated communication interface \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation\u003c\/strong\u003e: Mount the drive vertically. Deflections must remain within +\/- 10 degrees from the true vertical position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation and Cooling\u003c\/strong\u003e: Ensure unimpeded airflow around the chassis. The internal cooling fan requires a minimum air volume flow of \u003cstrong\u003e60 m3\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating\u003c\/strong\u003e: For operational environments between -10 degC and 50 degC, no derating is necessary. If the ambient operating temperature rises between 50 degC and 60 degC, an appropriate technical derating factor must be applied.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enclosure\u003c\/strong\u003e: The unit carries an \u003cstrong\u003eIP20\u003c\/strong\u003e rating and must be mounted inside an industrial enclosure providing protection against airborne contaminants, conforming to pollution degree 2 limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives \u0026amp; Standards\u003c\/strong\u003e: EN\/IEC 61800-5-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Marks \u0026amp; Approvals\u003c\/strong\u003e: CE, ATEX, UL, CSA, GOST, EAC, RCM, KC, NOM \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental \u0026amp; Sustainability\u003c\/strong\u003e: Green Premium Product, REACH Declaration, EU RoHS Directive, China RoHS Declaration, Mercury Free \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e: Immunity levels evaluated to IEC 61000-4-2 (Level 3), IEC 61000-4-3 (Level 3), IEC 61000-4-4 (Level 4), IEC 61000-4-5 (Level 3), IEC 61000-4-6 (Level 3), and IEC 61000-4-11 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat embedded communication interfaces are immediately accessible on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe variable speed drive comes standard with an integrated slave CANopen and Modbus serial interface protocol via its primary communication port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be adapted to other industrial fieldbus networks like PROFINET or EtherCAT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Communication modules for external networking architectures including PROFINET, EtherCAT, Profibus DP V1, Ethernet Powerlink, EtherNet\/IP, and DeviceNet are fully compatible via option card slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the default pulse configuration for the discrete logic input terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features 7 discrete inputs where terminal DI5 can be explicitly programmed to handle pulse configurations up to 30 kHz at 24 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this system require an external braking chopper for heavy-duty overhauling loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. An internal brake chopper is integrated directly within the unit, allowing for energy absorption and DC injection braking to standstill.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat thermal conditions must be maintained during active operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe operating range spans -10 degC up to 50 degC without losing performance metrics. Operation up to 60 degC is permissible provided a specific derating factor is implemente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104521052523,"sku":"ATV320U55N4B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv320u55n4b-4ehlwxfqier.png?v=1776162461"},{"product_id":"schneider-electric-140amm09000-modicon-quantum-analog-input-output-module","title":"Schneider Electric 140AMM09000 Modicon Quantum Analog Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003einput\/output analog module\u003c\/strong\u003e is designed for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e to provide high-precision analog signal interfacing within industrial control systems. The hardware integrates a single-pole low-pass filter providing a attenuation of -3 dB at 21 Hz (+\/- 20%) on the input circuit to manage electrical noise and ensure signal integrity.\u003c\/p\u003e\n\u003cp\u003eConfigured with \u003cstrong\u003e6 channels\u003c\/strong\u003e in total, the unit provides \u003cstrong\u003e4 analog inputs\u003c\/strong\u003e and \u003cstrong\u003e2 analog outputs\u003c\/strong\u003e. It features an addressing requirement of \u003cstrong\u003e5 input words\u003c\/strong\u003e and \u003cstrong\u003e2 output words\u003c\/strong\u003e. The input channels accommodate both bipolar and unipolar ranges, including \u003cstrong\u003ebipolar current (+\/- 20 mA)\u003c\/strong\u003e, \u003cstrong\u003ebipolar voltage (+\/- 10 V, +\/- 5 V)\u003c\/strong\u003e, \u003cstrong\u003eunipolar current (0...20 mA)\u003c\/strong\u003e, and configured offsets such as \u003cstrong\u003e4...20 mA\u003c\/strong\u003e and \u003cstrong\u003e1...5 V\u003c\/strong\u003e. The output circuits operate within a \u003cstrong\u003e4...20 mA\u003c\/strong\u003e range with an external loop voltage requirement. This combination allows reliable data acquisition and control tracking in continuous process fields.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Modularity\u003c\/strong\u003e: Features a 6-channel architecture providing 4 independent inputs and 2 dedicated outputs within a standard module format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Input Capabilities\u003c\/strong\u003e: Supports multiple signal configurations including unipolar current, unipolar offset current, bipolar current, unipolar voltage, and bipolar voltage profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Noise Suppression\u003c\/strong\u003e: Incorporates an integrated single-pole low-pass filter rated at -3 dB at 21 Hz (+\/- 20%) on the input circuit paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion\u003c\/strong\u003e: Delivers up to 16-bit resolution for voltage inputs, 15-bit for standard current inputs, and 12-bit resolution for the analog output loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Bus Isolation\u003c\/strong\u003e: Provides electrical isolation rated at 500 V AC or 750 V DC for 1 minute between independent channels, channels and bus, and between input\/output blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostic LEDs\u003c\/strong\u003e: Equipped with direct local signaling including a green bus active status indicator, a red external fault indicator, and 6 green\/red status markers for per-channel status and faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater and wastewater treatment monitoring\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n\u003cli\u003eBoiler control and steam management systems\u003c\/li\u003e\n\u003cli\u003eContinuous speed and position tracking loops\u003c\/li\u003e\n\u003cli\u003eMulti-channel data acquisition systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Input Number\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Modularity\u003c\/td\u003e\n\u003ctd\u003e6 channels \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Input Types \u0026amp; Resolution\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBipolar current: +\/- 20 mA (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eBipolar voltage: +\/- 10 V (16 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eBipolar voltage: +\/- 5 V (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar current: 0...20 mA (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar offset current: 4...20 mA (14 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar offset voltage: 1...5 V (14 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar voltage: 0...10 V (16 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar voltage: 0...5 V (15 bits DC) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAbsolute Maximum Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 25 mA current \/ +\/- 50 V voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm voltage \/ \u0026gt; 250 Ohm current \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB 50\/60 Hz input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUpdate Time (Input)\u003c\/td\u003e\n\u003ctd\u003e320 ms input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Number\u003c\/td\u003e\n\u003ctd\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Range\u003c\/td\u003e\n\u003ctd\u003e4...20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003e7...30 V DC output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLoop Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e0...60 V DC with external resistance output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e30 V DC 20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSetting Time\u003c\/td\u003e\n\u003ctd\u003e900 µs to +\/- 0.1% of the final value output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUpdate Time (Output)\u003c\/td\u003e\n\u003ctd\u003e15 ms output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Demands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e5 input words \/ 2 output words \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e350 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy \u0026amp; Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute Accuracy Error\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.03% at 25 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.20% of full scale at 25 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.05% of full scale max at 25 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.004% of full scale at 0...60 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOffset Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-0.0014 % of full scale max\/degC 0...60 degC input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eGain Shift\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 0.002 of full scale max 0...60 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.007 %\/degC of full scale max at 0...60 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute \/ 750 V DC for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChannel to Bus Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute \/ 750 V DC for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput to Output Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V for 1 minute \/ 750 V for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% without condensation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmbient Air Temp (Operation)\u003c\/td\u003e\n\u003ctd\u003e0...60 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmbient Air Temp (Storage)\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIndicator \/ Terminal Status\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Active LED (Green)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates active backplane bus communication is present \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Fault LED (Red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates an external fault condition has been detected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Active LEDs (6x Green)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually indicates that the corresponding channel is turned on \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Fault LEDs (6x Red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually indicates an active fault on the corresponding channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Placement\u003c\/strong\u003e: Mount the standard format module within a verified Modicon Quantum rack slot. Ensure proper retention screws are fastened to resist mechanical stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Connection\u003c\/strong\u003e: Secure an external power supply ranging from 7...30 V DC to drive the analog output circuit loops effectively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Use twisted-pair shielded cables for analog signal line routing. Ground the shields according to standard engineering practices to optimize common mode rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Thresholds\u003c\/strong\u003e: Ensure ambient air temperatures remain between 0 and 60 degC during active system operation, with relative humidity held below 95% without condensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No 142, UL 508 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: CE, C-Tick.1, FM Class 1 Division 2 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Field Resistance\u003c\/strong\u003e: 10 V\/m 80...2000 MHz conforming to IEC 801-3 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSustainability \u0026amp; Directives\u003c\/strong\u003e: Green Premium product, RoHS compliant (since date code 0842 Schneider Electric declaration of conformity), REACH reference not containing SVHC above the designated threshold \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific fault types can the diagnostic circuit paths register?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module detects an open circuit condition on both the input and output lines, an overtracking scale error on unipolar input loops, and updates the dedicated status byte for output parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the built-in filtering circuit on this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach input incorporates a single-pole low-pass filter providing an attenuation of -3 dB at 21 Hz (+\/- 20%) to damp high-frequency electrical noise before signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the analog output section draw its operating voltage directly from the backplane bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the module requires 350 mA from the backplane bus for internal processing, the analog output loop requires an independent external power connection supplying 7...30 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the isolation parameters between the input and output sides of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal dielectric boundaries provide continuous isolation rated up to 500 V AC or 750 V DC for 1 minute between the input channels and output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104522494315,"sku":"140AMM09000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140amm09000-ahxygsogmnz.png?v=1776159463"},{"product_id":"schneider-electric-nsycu2k-climasys-cu-enclosure-active-cooling-unit","title":"Schneider Electric NSYCU2K ClimaSys CU Enclosure Active Cooling Unit","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\n\u003cp\u003e\nThe Schneider Electric \u003cstrong\u003eNSYCU2K\u003c\/strong\u003e is a heavy-duty, side-mounting electronic enclosure climate controller belonging to the specialized ClimaSys CU product family. Engineered to maintain rigorous thermal stabilization inside sealed electrical cabinets, this compressor-based system delivers a nominal cooling power of 2000 W under standard L35-L35 rating criteria. In volatile process environments such as oil and gas refining, thermal power generation facilities, and automated aggregate processing plants, excessive thermal pockets lead directly to the premature tripping or permanent failure of high-density PLCs, variable frequency drives, and system backplanes. The \u003cstrong\u003eNSYCU2K\u003c\/strong\u003e mitigates these structural risks by forcefully extracting internal heat loads while maintaining a continuous environmental barrier. The dual-loop circuit layout isolates contaminated factory air from the clean interior loop, driving down heat-induced processing downtime and protecting high-value control assets.\n\u003c\/p\u003e\n\n\u003ch3\u003eHardware Infrastructure \u0026amp; Fluid Dynamics\u003c\/h3\u003e\n\n\u003cp\u003e\nThe mechanical architecture of this active cooling system is built upon a rigid, industrial-grade steel chassis finished in standard RAL 7035 grey coating. Designed specifically for indoor screw-mount integration on enclosure doors or side panels, it uses a closed-loop R134a refrigerant system charged with 0.54 kg of gas to achieve an Energy Efficiency Ratio (EER) of 1.9. The unit incorporates high-capacity motorized fans that move air through the internal circuit at 860 m3\/h and the external ambient loop at 1050 m3\/h. For automated configuration, an onboard digital electronic controller regulates system operation based on selectable parameters, adapting automatically to distinct thermal thresholds across 50 Hz and 60 Hz electrical networks.\n\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Parameters Matrix\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eCertified Performance Data\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eNSYCU2K\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eBrand\u003c\/td\u003e\n            \u003ctd\u003eSchneider Electric\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRange\u003c\/td\u003e\n            \u003ctd\u003eClimaSys CU\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMounting Type\u003c\/td\u003e\n            \u003ctd\u003eSide-mount or Door-mount (Indoor)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRated Power Consumption\u003c\/td\u003e\n            \u003ctd\u003e1080 W at L35-L35 \/ 1290 W at L35-L50\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNominal Cooling Power\u003c\/td\u003e\n            \u003ctd\u003e2000 W at L35-L35 \/ 1510 W at L35-L50\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Operating Voltage\u003c\/td\u003e\n            \u003ctd\u003e230 VAC, 1-phase, 50\/60 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFull Load Rated Current\u003c\/td\u003e\n            \u003ctd\u003e6.5 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePeak Inrush Current\u003c\/td\u003e\n            \u003ctd\u003e24 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIntegrated Gas Charge\u003c\/td\u003e\n            \u003ctd\u003eR134a (0.54 kg)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTarget Temperature Set Window\u003c\/td\u003e\n            \u003ctd\u003e20 to 55 deg C (50 Hz) \/ 20 to 50 deg C (60 Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInternal Loop Protection\u003c\/td\u003e\n            \u003ctd\u003eIP55 conforming to IEC 60529\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eExternal Loop Protection\u003c\/td\u003e\n            \u003ctd\u003eIP34 conforming to IEC 60529\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSound Pressure Level\u003c\/td\u003e\n            \u003ctd\u003e65 dB conforming to EN\/ISO 3746\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMaximum System Pressure\u003c\/td\u003e\n            \u003ctd\u003e25 bar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNet Weight\u003c\/td\u003e\n            \u003ctd\u003e52 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n            \u003ctd\u003e999 mm Height x 405 mm Width x 237 mm Depth\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eField Diagnostics \u0026amp; Application FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhy does the system list two distinct cooling capacities (2000 W and 1510 W)?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nCooling output depends on thermal gradients. Under L35-L35 parameters (internal cabinet air and external ambient air both at 35 deg C), the unit outputs its full 2000 W capacity. When ambient plant temperatures rise to 50 deg C (L35-L50 conditions), the compressor works against a higher thermal head, reducing net sensible cooling output to 1510 W while power consumption climbs to 1290 W.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhat specific protective electrical hardware must be installed upstream of this unit?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nDue to the inductive startup profile of the compressor motor, which draws a transient 24 A inrush current, a dedicated thermal protection fuse rated at 10 A (Time-delay \/ Type T) or a magnetic motor circuit breaker with matching delay characteristics must be installed to prevent nuisance tripping during start-up cycles.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCan this unit operate reliably in high-dust or chemical fiber environments?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nYes, but it requires accessory hardware. While the internal circuit is sealed to IP55, the unsealed external circuit operates at IP34. For areas with high concentrations of airborne particulate matter, non-conductive dust, or fibers, field technicians must install the optional external circuit filter to keep the condenser fins clear and maintain proper heat transfer efficiency.\n\u003c\/p\u003e\n\n\u003ch3\u003eField Commissioning \u0026amp; Structural Installation Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eMechanical Panel Preparation:\u003c\/strong\u003e Utilize the factory cutout blueprint to trace and execute precise intake and exhaust apertures on the side panel or door of the Spacial enclosure. Remove all metal shavings, smooth out raw cut lines, and treat the bare steel borders with zinc-rich anti-corrosion primer before proceeding with mechanical fastening.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eGasket Compression and Sealing:\u003c\/strong\u003e Apply the continuous polyurethane sealing strip around the rear chassis mounting perimeter without overlaps or gaps. Lift the 52 kg unit using mechanical hoist assists and secure it via the specified mounting screws through the cabinet wall. Tighten fasteners uniformly to ensure uniform gasket compression, establishing the certified IP55 internal loop barrier.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eAirstream Path Clearances:\u003c\/strong\u003e To maintain optimal air movement profiles (860 m3\/h internal \/ 1050 m3\/h external), ensure internal panel components, wireways, or structural plates sit at least 150 mm away from the internal intake and exhaust vents. Externally, maintain a minimum clear radius of 500 mm to prevent the re-ingestion of hot exhaust air.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eCondensate Management and Slope:\u003c\/strong\u003e Mount the cooling unit perfectly plumb in both horizontal and vertical planes onto a rigid structure. Misalignments or tilting can disrupt the internal gravity-fed condensation path, leading to localized water accumulation or moisture migration into the low-voltage areas of the industrial enclosure.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104571810155,"sku":"NSYCU2K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nsycu2k-pcxq3jda0fs.png?v=1776163430"},{"product_id":"tsxpbsca100-schneider-electric-modicon-quantum-profibus-dp-cable-100m","title":"TSXPBSCA100 Schneider Electric Modicon Quantum Profibus DP Cable 100m","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100 (TSXPBSCA100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium-grade Profibus DP communication cable engineered for high-speed data transmission within the Schneider Electric Modicon Quantum and Premium automation platforms. This 100 m (328 ft) bulk cable reel is specifically designed to facilitate robust connectivity between Profibus master\/slave modules and field devices in distributed I\/O architectures. Utilized extensively in large-scale industrial sectors such as water wastewater treatment, automotive assembly, and chemical processing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures low-latency communication over long distances. Its industrial-strength shielding is critical for maintaining signal integrity in environments saturated with electromagnetic interference (EMI), effectively preventing data packet loss and minimizing network-related system downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized RS-485 based twin-axial cable optimized for the Profibus DP (Decentralized Periphery) protocol. The internal architecture features high-purity copper conductors protected by a high-density braided shield and foil wrap, providing dual-layer protection against high-frequency noise and electrical transients. The outer jacket is composed of a durable, flame-retardant compound capable of withstanding the rigors of industrial cable trays and conduits. This cable is designed for use with standard 9-pin D-Sub Profibus connectors, supporting transmission speeds up to 12 Mbps. Its 100 m length provides the flexibility needed for expansive plant layouts, allowing for the strategic positioning of remote I\/O drops without the need for frequent repeaters.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eTSXPBSCA100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eModicon Quantum \/ Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eProfibus DP Communication Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e100 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eTransmission Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eUp to 12 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eCommunication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eProfibus DP (RS-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e5.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e33 x 33 x 13.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eProduct Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eActive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TSXPBSCA100 cable be used for both Profibus DP and Profibus PA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is specifically optimized for Profibus DP (RS-485).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-975\"\u003eWhile the physical layer of Profibus PA is different (Manchester Bus Powered), the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan class=\"citation-975 citation-end-975\"\u003e\u003cspan\u003e \u003c\/span\u003eis the standard for high-speed DP communication between PLCs and devices like variable speed drives or remote I\/O.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it necessary to use specific connectors with this 100 m reel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, for industrial reliability, it is recommended to use Schneider Electric 490NAE91102 or equivalent Profibus connectors. These connectors provide the necessary termination resistors required at the physical ends of the network segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum segment length supported by this cable at 1.5 Mbps?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccording to Profibus standards, a single segment using this type of high-quality cable can reach up to 200 m at 1.5 Mbps. For the full 12 Mbps speed, the segment length should generally not exceed 100 m without a repeater.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, strictly observe a minimum bend radius of at least 75 mm. Kinking or over-bending the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan deform the internal dielectric and shielding geometry, leading to impedance mismatches and signal reflections that cause intermittent bus errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Continuity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen stripping the cable for connector assembly, ensure the braided shield makes 360-degree contact with the metal housing of the Profibus connector. This ensures a continuous path to ground for induced noise, which is vital for the 12 Mbps high-speed data rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation from Power Cabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo avoid inductive coupling, maintain a minimum clearance of 20 cm between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand AC power cables (above 230V). If the communication cable must cross a power cable, ensure it does so at a 90-degree angle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways verify that the termination switches on the connectors at the first and last physical nodes of the 100 m segment are set to the \"ON\" position. Intermediate nodes must have the termination switch set to \"OFF\" to prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572760427,"sku":"TSXPBSCA100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpbsca100-ahsijylm3kk.png?v=1776164423"},{"product_id":"schneider-modicon-quantum-140noc78100-ethernet-dio-module","title":"Schneider Modicon Quantum 140NOC78100 Ethernet DIO Module","description":"\u003cp\u003eThe \u003cstrong\u003e140NOC78100\u003c\/strong\u003e is a \u003cstrong\u003eModicon Quantum Ethernet DIO module\u003c\/strong\u003e engineered to facilitate high-speed, reliable communication between the Quantum controller and distributed I\/O devices over an Ethernet network. As a core networking component for the \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e range, this module supports the implementation of distributed I\/O architectures, allowing for flexible system expansion and enhanced data exchange capabilities in complex industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e series compatibility\u003c\/li\u003e\n\u003cli\u003eEthernet-based distributed I\/O (DIO) communication\u003c\/li\u003e\n\u003cli\u003eOptimized for networked industrial automation systems\u003c\/li\u003e\n\u003cli\u003eCompact, rack-mount design for efficient cabinet space utilization\u003c\/li\u003e\n\u003cli\u003eReliable performance for critical industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale distributed process control systems\u003c\/li\u003e\n\u003cli\u003eManufacturing automation and machine control\u003c\/li\u003e\n\u003cli\u003eBuilding management and infrastructure monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet network backbone expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet DIO Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.50 x 31.50 x 4.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the \u003cstrong\u003e140NOC78100\u003c\/strong\u003e directly into a standard Modicon Quantum backplane. Ensure the module is fully seated to establish proper electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connectivity:\u003c\/strong\u003e Use high-quality shielded twisted-pair (STP) Ethernet cabling to ensure robust signal integrity and minimize interference in industrial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the rack is properly grounded to the cabinet’s main earth bus to protect against transient electrical disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Protect the module from extreme temperature fluctuations and excessive humidity, maintaining operation within specified industrial cabinet conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Separate communication cables from high-voltage power lines to prevent electromagnetic interference (EMI) and signal crosstalk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572793195,"sku":"140NOC78100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140noc78100-0jfs4pyh3fk.png?v=1776159626"},{"product_id":"schneider-altivar-212-atv212wu75n4c-variable-frequency-drive","title":"Schneider Altivar 212 ATV212WU75N4C Variable Frequency Drive","description":"\u003cp\u003eThe \u003cstrong\u003eATV212WU75N4C\u003c\/strong\u003e is a \u003cstrong\u003evariable frequency drive\u003c\/strong\u003e from the \u003cstrong\u003eAltivar 212\u003c\/strong\u003e series, specifically engineered for HVAC applications. This \u003cstrong\u003e7.5 kW\u003c\/strong\u003e drive operates on a \u003cstrong\u003e480 V\u003c\/strong\u003e three-phase power supply, providing efficient motor control for pumps, fans, and compressor systems. Built with an \u003cstrong\u003eIP55\u003c\/strong\u003e enclosure rating and \u003cstrong\u003eEMC class C1\u003c\/strong\u003e compliance, it is designed for demanding industrial and commercial environments where protection against dust and water jets is required.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltivar 212\u003c\/strong\u003e series optimized for HVAC control\u003c\/li\u003e\n\u003cli\u003ePower rating of \u003cstrong\u003e7.5 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-phase input voltage of \u003cstrong\u003e480 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP55\u003c\/strong\u003e protection rating for reliable performance in harsh environments\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eEMC class C1\u003c\/strong\u003e filter for reduced electromagnetic interference\u003c\/li\u003e\n\u003cli\u003eCompact, robust design for versatile installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC system fan control\u003c\/li\u003e\n\u003cli\u003eCentrifugal and circulation pump systems\u003c\/li\u003e\n\u003cli\u003eBuilding management system (BMS) integration\u003c\/li\u003e\n\u003cli\u003eIndustrial process ventilation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltivar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable frequency drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhases\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Class\u003c\/td\u003e\n\u003ctd\u003eC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e36.00 x 41.50 x 27.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure sufficient space around the drive to allow for adequate airflow and cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The \u003cstrong\u003eATV212WU75N4C\u003c\/strong\u003e must be mounted vertically on a flat, non-flammable surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cables for motor connections to maintain \u003cstrong\u003eEMC class C1\u003c\/strong\u003e compliance. Ensure all grounding connections are secure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Protect the drive from direct sunlight, corrosive gases, and excessive vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Follow proper cable routing practices to separate power cables from control and communication signals to prevent interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572825963,"sku":"ATV212WU75N4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv212wu75n4c-ih2gbpajagp.png?v=1776162226"},{"product_id":"schneider-altistart-1-ats01n244ly-soft-starter","title":"Schneider Altistart 1 ATS01N244LY Soft Starter","description":"\u003cp\u003eThe \u003cstrong\u003eATS01N244LY\u003c\/strong\u003e is a \u003cstrong\u003esoft starter\u003c\/strong\u003e from the \u003cstrong\u003eAltistart 1\u003c\/strong\u003e series, engineered for the controlled starting and stopping of three-phase asynchronous motors. This unit is rated for a capacity of \u003cstrong\u003e11 kW\u003c\/strong\u003e and provides a nominal current of \u003cstrong\u003e44 A\u003c\/strong\u003e. It is designed to reduce mechanical stress on driven equipment by providing smooth acceleration and deceleration, preventing torque shocks and current spikes during power-up sequences.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltistart 1\u003c\/strong\u003e series soft starter technology\u003c\/li\u003e\n\u003cli\u003eNominal operating current: \u003cstrong\u003e44 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower rating: \u003cstrong\u003e11 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompact design for space-efficient integration in control cabinets\u003c\/li\u003e\n\u003cli\u003eDesigned for smooth motor starting and stopping applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConveyor systems and material handling equipment\u003c\/li\u003e\n\u003cli\u003eCentrifugal pumps and small fan systems\u003c\/li\u003e\n\u003cli\u003eCompressors and light industrial machinery\u003c\/li\u003e\n\u003cli\u003eEquipment requiring minimized mechanical torque impact during startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Current\u003c\/td\u003e\n\u003ctd\u003e44 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The \u003cstrong\u003eATS01N244LY\u003c\/strong\u003e should be installed in a vertical position to ensure proper heat dissipation. Maintain sufficient clearance above and below the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation site is free from conductive dust, moisture, and extreme temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the power supply to the input terminals and the motor to the output terminals according to the wiring diagram provided in the user documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e It is recommended to install external short-circuit protection (fuses or circuit breakers) upstream to protect the soft starter and motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure the electrical enclosure is adequately ventilated to prevent internal temperature rise beyond operational limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572858731,"sku":"ATS01N244LY","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats01n244ly-y2kzils1gmx.png?v=1776162047"},{"product_id":"schneider-modicon-premium-tsxp573623amc-pl7-processor","title":"Schneider Modicon Premium TSXP573623AMC PL7 Processor","description":"\u003cp\u003eThe \u003cstrong\u003eTSXP573623AMC\u003c\/strong\u003e is a \u003cstrong\u003edouble-format PL7 processor\u003c\/strong\u003e designed for the \u003cstrong\u003eModicon Premium\u003c\/strong\u003e automation platform. This module features \u003cstrong\u003eTransparent Ready\u003c\/strong\u003e capabilities, enabling direct integration into industrial Ethernet architectures for transparent data exchange and remote management. As a high-performance central processing unit, it supports complex control logic and demanding automation tasks while maintaining compatibility with legacy Premium series hardware infrastructures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-format processor architecture for Modicon Premium systems\u003c\/li\u003e\n\u003cli\u003eTransparent Ready integration for simplified network connectivity\u003c\/li\u003e\n\u003cli\u003eIntegrated power consumption capacity of 1360 mA\u003c\/li\u003e\n\u003cli\u003eDesigned for robust control and automation environment scalability\u003c\/li\u003e\n\u003cli\u003eCompatible with standard PL7 programming software environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated manufacturing process control\u003c\/li\u003e\n\u003cli\u003eLegacy system infrastructure upgrades and maintenance\u003c\/li\u003e\n\u003cli\u003eCentralized machine automation and monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet-based data acquisition systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePL7 Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1360 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eDouble-Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 x 26.00 x 9.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.61 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eRefer to product label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control:\u003c\/strong\u003e Ensure the installation environment is free from excessive dust, corrosive gases, and extreme moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the \u003cstrong\u003eTSXP573623AMC\u003c\/strong\u003e in a standard Modicon Premium rack, ensuring proper alignment with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Maintain adequate clearance around the module to allow for natural convection cooling, as per the rack ventilation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Observe electrostatic discharge (ESD) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Verify that the power supply module matches the 1360 mA consumption requirements of the processor and the overall rack configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572891499,"sku":"TSXP573623AMC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp573623amc-oime3qtnqb2.png?v=1776164349"},{"product_id":"schneider-modicon-premium-tsxaey800c-analog-input-module","title":"Schneider Modicon Premium TSXAEY800C Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXAEY800C\u003c\/strong\u003e is a \u003cstrong\u003eModicon Premium analog input module\u003c\/strong\u003e designed to provide high-precision data acquisition for industrial control systems. This module features 8 multirange analog inputs with a common point, allowing for versatile sensor interfacing across various signal standards. Engineered for the Modicon Premium platform, the \u003cstrong\u003eTSXAEY800C\u003c\/strong\u003e ensures reliable, consistent data conversion, making it a critical component for monitoring processes, temperature, pressure, and other variable industrial parameters.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 multirange analog inputs\u003c\/li\u003e\n\u003cli\u003eCommon point input configuration\u003c\/li\u003e\n\u003cli\u003eDesigned for the Modicon Premium automation platform\u003c\/li\u003e\n\u003cli\u003eVersatile sensor and signal compatibility\u003c\/li\u003e\n\u003cli\u003eReliable data conversion for industrial monitoring\u003c\/li\u003e\n\u003cli\u003eCompact design for rack-mount integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess automation and monitoring\u003c\/li\u003e\n\u003cli\u003eData acquisition for SCADA systems\u003c\/li\u003e\n\u003cli\u003eIndustrial instrumentation and sensor interfacing\u003c\/li\u003e\n\u003cli\u003eEnvironmental parameter tracking\u003c\/li\u003e\n\u003cli\u003ePrecision control of analog feedback loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eMultirange (Common point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 x 26.00 x 5.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the module into the Modicon Premium rack, ensuring the backplane connector is fully engaged and the module is locked into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded, twisted-pair cables to connect analog sensors to the input terminals to minimize noise interference. Maintain proper segregation between analog signal wiring and high-power cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a reliable common point connection as required by the specific application architecture to ensure accurate signal referencing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Verify input scaling and range configuration within the PLC programming environment to match the specific signal output of connected sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation environment is free from excessive electromagnetic noise and vibration to maintain measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572924267,"sku":"TSXAEY800C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxaey800c-zvkmsygnusk.png?v=1776163719"},{"product_id":"schneider-electric-tsxpbsca400-modicon-quantum-profibus-dp-connection-cable","title":"Schneider Electric TSXPBSCA400 Modicon Quantum Profibus DP Connection Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA400 (TSX-PBS-CA400)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Profibus DP connection cable engineered for the Modicon Quantum automation platform. Spanning a total length of 400 meters, this specialized communication medium is designed to facilitate seamless data exchange between PLC processors and remote I\/O stations in demanding industrial environments such as oil refineries, power generation plants, and large-scale mining operations. Given its Phase-Out status, securing this original Schneider Electric component is critical for maintaining legacy infrastructure integrity, preventing costly downtime, and ensuring the deterministic performance required for mission-critical control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eAs a dedicated Profibus DP (Decentralized Periphery) physical layer component, this cable features optimized impedance and shielding characteristics to mitigate electromagnetic interference (EMI) over long-distance runs. The 400-meter bulk reel allows for custom length termination or extensive trunk line deployment without the need for additional repeaters in many standard RS-485 network topologies. It is fully compliant with the Modicon Quantum architecture, supporting high-speed cyclic data exchange and diagnostics across the Profibus fieldbus network.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXPBSCA400\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP Connection Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 x 50 x 41.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXPBSCA400 compatible with other Modicon series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile specifically categorized under the Modicon Quantum range, this cable follows standard Profibus DP physical layer specifications and can be utilized with Modicon M580 or M340 systems provided the appropriate Profibus communication modules and connectors are employed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Phase-Out status affect future maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs this product is in the Phase-Out phase, Schneider Electric may limit new production. It is highly recommended to maintain onsite spares to ensure immediate recovery during cable damage scenarios, as lead times for legacy accessories typically increase over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the grounding requirements for a 400-meter run?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent ground loops while maintaining EMI protection, the cable shield should be integrated via 360-degree contact at the connector level. In extended runs, ensure that the potential equalization between different plant areas is within the specified limits of the Profibus standard.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, maintain a minimum bend radius of at least 15 times the outer diameter of the cable. Excessive kinking can alter the internal geometry of the twisted pair, leading to signal reflection and intermittent \"Bus Heavy\" errors in the PLC diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation from Power Lines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, route this cable in separate conduits from high-voltage motor leads or VFD outputs. A minimum clearance of 20 cm is recommended in parallel runs to prevent inductive coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough designed for industrial use, if the cable is routed through areas with high chemical exposure or standing water, it must be protected by liquid-tight flexible conduits. Ensure all Profibus connectors are tightened to the specified torque to maintain IP-rated seals at the module interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572957035,"sku":"TSXPBSCA400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpbsca400-053kxpxmjyq.png?v=1776164424"},{"product_id":"schneider-altistart-22-ats22d62s6-soft-starter","title":"Schneider Altistart 22 ATS22D62S6 Soft Starter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS22D62S6\u003c\/strong\u003e is an \u003cstrong\u003eAltistart 22 soft starter\u003c\/strong\u003e engineered for the controlled starting and stopping of three-phase asynchronous motors. Rated for a continuous current of 62 A, this unit supports motors with power ratings ranging from 15 kW to 37 kW within a wide voltage spectrum of 230 V to 600 V. By managing voltage and torque, the \u003cstrong\u003eATS22D62S6\u003c\/strong\u003e reduces mechanical stress on drive systems and limits high inrush currents during startup. The integrated bypass contactor improves energy efficiency and reduces heat generation during steady-state motor operation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated operational current: 62 A\u003c\/li\u003e\n\u003cli\u003eVoltage range: 230-600 V\u003c\/li\u003e\n\u003cli\u003eMotor power capacity: 15-37 kW\u003c\/li\u003e\n\u003cli\u003eIntegrated bypass contactor for thermal efficiency\u003c\/li\u003e\n\u003cli\u003eAdvanced motor protection algorithms\u003c\/li\u003e\n\u003cli\u003eCompact design optimized for industrial control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal pumps and fan control\u003c\/li\u003e\n\u003cli\u003eIndustrial compressors and blowers\u003c\/li\u003e\n\u003cli\u003eMaterial handling equipment and conveyors\u003c\/li\u003e\n\u003cli\u003eGear-driven machinery\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose industrial motor management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e62 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e230 - 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating\u003c\/td\u003e\n\u003ctd\u003e15 - 37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e36 x 25 x 30 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the device vertically on a rigid, fire-resistant surface to ensure optimal cooling and structural integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain specified clearances around the unit to prevent heat accumulation. Ensure airflow paths remain unobstructed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately rated cables for the 62 A current. Ensure all power terminals are tightened to the torque specifications provided in the technical documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the unit’s grounding terminal to the cabinet protective earth (PE) to ensure electrical safety and EMC compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Install input circuit protection (fuses or circuit breakers) as required by local electrical standards to protect the soft starter and motor circuit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572989803,"sku":"ATS22D62S6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats22d62s6-qmw42ux1rdk.png?v=1776162078"},{"product_id":"schneider-modicon-quantum-140dai74000-discrete-input-module","title":"Schneider Modicon Quantum 140DAI74000 Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e140DAI74000\u003c\/strong\u003e is a 16-channel discrete input module engineered for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e. Operating at a nominal voltage of 230 V AC, this module provides the interfacing capacity necessary to register high-voltage digital signals from field devices such as pushbuttons, limit switches, and electrical interlocks. It captures alternating current states and processes them into a single 1 input word format for execution within the main processor rack.\u003c\/p\u003e\n\u003cp\u003eIntegrated into the system architecture via \u003cstrong\u003eUnity Pro\u003c\/strong\u003e, \u003cstrong\u003eConcept\u003c\/strong\u003e, or \u003cstrong\u003eProWORX 32\u003c\/strong\u003e programming frameworks, the module interfaces with the local controller backplane via standard bus routing protocol. The unit is specialized for high-power processing environments where separate tracking of independent AC input circuits is mandatory to prevent cross-talk and maintain signal safety. It handles discrete data conversion with an optimized response time profile and high electrical isolation thresholds between channels as well as across the bus lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures 16 discrete input channels structured in an isolated group layout \u003c\/li\u003e\n\u003cli\u003eOperates on a wide 230 V AC input range compatible with dual network frequencies (57...63 Hz or 47...53 Hz) \u003c\/li\u003e\n\u003cli\u003eHigh channel-to-channel and channel-to-bus galvanic isolation rated at 1780 Vrms for 1 minute \u003c\/li\u003e\n\u003cli\u003eEquipped with front-panel local signaling LEDs including 1 green bus communication indicator, 1 red external fault warning, and 16 green individual input status lights \u003c\/li\u003e\n\u003cli\u003eLow bus current requirement of 180 mA to optimize backplane power distribution \u003c\/li\u003e\n\u003cli\u003eStandard module format fits seamlessly into any open Modicon Quantum slot position \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain power plant control and distribution substation monitoring\u003c\/li\u003e\n\u003cli\u003eHeavy infrastructure control systems including municipal water treatment facilities\u003c\/li\u003e\n\u003cli\u003eSafety interlocking logic for high-voltage industrial machinery and switchgears\u003c\/li\u003e\n\u003cli\u003eMarine and offshore production platform auxiliary process systems\u003c\/li\u003e\n\u003cli\u003eManufacturing lines utilizing 230 V AC field machinery sensor arrays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eVAC discrete input modules \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Number\u003c\/td\u003e\n\u003ctd\u003e16 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup of Channels\u003c\/td\u003e\n\u003ctd\u003e16 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e1 input word \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt;= 11.5 mA at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e\u0026lt;= 9.7 mA at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage State 1 Guaranteed\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e165...264 V AC at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e175...264 V AC at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage State 0 Guaranteed\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0...40 V AC at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e0...40 V AC at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e26500 Ohm capacitive at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e31800 Ohm capacitive at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency Limits\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.6 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Input\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264 V continuous\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e300 V 10 s\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e400 V 1 cycle \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.9...0.75 ms x line cycle Off-On\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e7.3...12.3 ms On-Off \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels and Bus\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e180 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5.5 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Operation\u003c\/td\u003e\n\u003ctd\u003e0...60 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Storage\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% without condensation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to Electrostatic Discharge\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 kV contact conforming to IEC 801-2\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e8 kV on air conforming to IEC 801-2 \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to Electromagnetic Fields\u003c\/td\u003e\n\u003ctd\u003e10 V\/m 80...2000 MHz conforming to IEC 801-3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Turn off all rack power supplies prior to positioning the input module into the target Quantum slot. Push the unit firmly until the module connector fully seats into the backplane bus interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Routing:\u003c\/strong\u003e Route all high-voltage 230 V AC external field cabling through separate wire ducts distinct from low-voltage DC signals and communication lines to mitigate cross-coupling and electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Requirements:\u003c\/strong\u003e Verify that the enclosure layout preserves natural convection airways. Ensure the operating environment does not surpass the upper thermal barrier of 60 degC and that non-condensing moisture stays within 95% relative humidity constraints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Earth Grounding:\u003c\/strong\u003e Confirm the main Modicon Quantum mounting rack features an uncompromised, low-impedance ground bonding strap connected directly to the primary structural earth terminal of the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarking: CE \u003c\/li\u003e\n\u003cli\u003eStandards: CSA C22.2 No 142, UL 508 \u003c\/li\u003e\n\u003cli\u003eProduct Certifications: FM Class 1 Division 2, CUL \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the distinct front-panel signaling LEDs mean during normal operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe top green LED remains illuminated when active bus communication is running across the backplane. The red LED illuminates if an external fault is detected. The remaining block of 16 green LEDs individually follow the on\/off state transitions of the corresponding AC field input lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum allowed temporary voltage spike that the inputs can withstand?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input channels tolerate absolute maximum voltage boundaries up to 300 V for a duration of 10 seconds and 400 V for a brief single line cycle without suffering permanent component failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be programmed using standard EcoStruxure Control Expert software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, since this module functions under the standard Unity Pro engine framework, it remains compatible with legacy Unity Pro applications as well as updated development suites from Schneider Electric.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573186411,"sku":"140DAI74000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140dai74000-d5awyvvdwhg.png?v=1776159574"},{"product_id":"schneider-modicon-premium-tsxispy121-isp-plus-weighing-module","title":"Schneider Modicon Premium TSXISPY121 ISP Plus Weighing Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXISPY121\u003c\/strong\u003e functions as a high-precision \u003cstrong\u003eISP Plus weighing module\u003c\/strong\u003e developed for integration within the \u003cstrong\u003eModicon Premium Automation platform\u003c\/strong\u003e. This specialized hardware subassembly executes rapid industrial weight data acquisition, supporting processing rates of up to 50 measurements per second. The device features a single measurement input channel with an analogue input resolution of 20 bits, translating to an internal capacity of 1,048,857 points. Designed to supply stabilized power directly to connected sensors, it outputs a constant 10 V DC sensor power supply to drive external field components.\u003c\/p\u003e\n\u003cp\u003eFor localized process adjustments, the hardware incorporates \u003cstrong\u003ediscrete reflex\u003c\/strong\u003e outputs with a rapid response time of 1 ms, handling positive switching states up to 500 mA at 24 V DC. Communication infrastructure is facilitated by an unisolated RS485 serial link operating at a transmission rate of 9.6 kbit\/s, enabling dedicated connection paths directly to a Magelis weight indicator. This architecture makes the module highly suitable for industrial batching, filling, and dynamic crane or hopper weighing procedures across modern production lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion\u003c\/strong\u003e: Employs a 20-bit internal analog-to-digital converter achieving a total resolution of 1,048,857 points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measuring Frequency\u003c\/strong\u003e: Executes up to 50 discrete weight measurements per second for responsive automation tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Reflex Outputs\u003c\/strong\u003e: Provides 2 positive reflex outputs with an ultra-low response time of 1 ms for precise batch cutoff control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Sensor Power Management\u003c\/strong\u003e: Supplies an onboard 10 V DC power path dedicated exclusively to attached bridge load cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Serial Bus\u003c\/strong\u003e: Features a built-in unisolated RS485 serial link optimized for dedicated remote weight indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Premium Form Factor\u003c\/strong\u003e: Built to fit seamlessly into standard Modicon Premium rack slot allocations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial container and silo hopper weight monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-speed automated batching and formula blending systems\u003c\/li\u003e\n\u003cli\u003eMaterial packaging, bagging, and inline check-weighing machinery\u003c\/li\u003e\n\u003cli\u003eCrane overload protection and heavy material handling tracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (LC Schneider) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTSXISPY121 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISP Plus weighing module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Measurement Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Input Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 bits (1048576 points) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurements per second \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MOhm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad cell 1...8 350 Ohm yes \u0026lt;= 300 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete reflex 2 positive \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time on Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s RS485 non isolated \u0026lt;= 30 m discrete reflex weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Division\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 uV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Cable Distance Between Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 m for module\/weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mA at 24 V rack \/ 150 mA at 5 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...95% non-condensing (operation) \/ 5...95% non-condensing (storage) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...2000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Interface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 connector screw terminal block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUsed for connecting 2 discrete reflex outputs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 female connector SUB-D 15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated for the indicator input lines \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 female connector SUB-D 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides the RS485 serial link connection to the weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eRack Placement and Insertion\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the primary rack power supply of the Modicon Premium automation platform is switched off before inserting or extracting the hardware.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly along the structural chassis alignment paths until the rear terminal contacts mate completely into the active rack bus lines.\u003c\/li\u003e\n\u003cli\u003eTighten the integrated faceplate screws to confirm grounding and safeguard against vibration displacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Length and Isolation Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKeep the interconnection distance between the main weighing block and the dedicated remote weight indicator below the specified 3 m distance boundary to avoid transmission losses.\u003c\/li\u003e\n\u003cli\u003eWhen implementing field extensions for the load cell inputs, ensure the maximum shielding run does not exceed 300 m.\u003c\/li\u003e\n\u003cli\u003eRun all low-voltage analog load cell sensor cabling inside isolated trays, separated completely from primary high-current AC machinery power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE \u003c\/li\u003e\n\u003cli\u003eSDM No 97.06 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat parameters govern the sensor compatibility for this weighing module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe module is designed to interface seamlessly with standard strain-gauge load cells, supporting configurations ranging from 1 to 8 parallel load cells with a nominal bridge resistance of 350 Ohm up to a maximum distance boundary of 300 m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary electrical draws exerted by this unit on the main rack assembly?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe device pulls electrical current across two distinct voltage rails provided by the Modicon backplane, consuming 145 mA at the 24 V rack supply line while simultaneously drawing 150 mA from the localized 5 V DC internal distribution rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the direct physical reflex output channels bound to external switching loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e External loops hook directly into the integrated terminal interface using a dedicated single connector screw terminal block layout, which distributes the two positive 24 V DC reflex switching points out to localized relays or indicators.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573219179,"sku":"TSXISPY121","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxispy121-muccmmkuu2c.png?v=1776164103"},{"product_id":"schneider-modicon-premium-tsxp572623-pl7-processor-module","title":"Schneider Modicon Premium TSXP572623 PL7 Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXP572623\u003c\/strong\u003e is a single-slot processor module designed for the \u003cstrong\u003eModicon Premium\u003c\/strong\u003e automation platform. It manages autonomous PLC stations, coordinates distributed I\/O, and executes specialized tasks such as counting, motion control, and communication processing via the \u003cstrong\u003ePL7 Software\u003c\/strong\u003e environment.\u003c\/p\u003e\n\u003cp\u003eThis processing unit coordinates real-time discrete and analog operations across industrial machinery, manufacturing lines, and process control infrastructure. It features embedded system memory for application code, registers, and system diagnostics, with hardware support for localized rack configurations and distributed fieldbus networking. The module maintains full backward and vertical architectural consistency with the standard \u003cstrong\u003eTSX 57\u003c\/strong\u003e product range.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard single-slot form factor for Modicon Premium TSXRKY rack mounting\u003c\/li\u003e\n\u003cli\u003eIntegrated system flash memory for firmware and application logic protection\u003c\/li\u003e\n\u003cli\u003eDual PCMCIA card slots for memory extension and auxiliary network communication\u003c\/li\u003e\n\u003cli\u003eEmbedded diagnostic indicators for system status, I\/O faults, and communication states\u003c\/li\u003e\n\u003cli\u003eBuilt-in real-time clock for system timestamping and structured event logging\u003c\/li\u003e\n\u003cli\u003eSoftware configuration and application programming using PL7 Micro, Junior, or Pro\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive assembly lines and component testing machinery\u003c\/li\u003e\n\u003cli\u003eWater and wastewater pumping stations and treatment facilities\u003c\/li\u003e\n\u003cli\u003eMaterial handling, sorting systems, and conveyor line management\u003c\/li\u003e\n\u003cli\u003ePackaging infrastructure and high-speed filling equipment\u003c\/li\u003e\n\u003cli\u003eAuxiliary process loop controls in food, beverage, and chemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTSXP572623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slot Width\u003c\/td\u003e\n\u003ctd\u003e1 Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e1650 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissipated Power\u003c\/td\u003e\n\u003ctd\u003e8.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e96 Kwords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Software Support\u003c\/td\u003e\n\u003ctd\u003ePL7 Micro \/ Junior \/ Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e40 mm x 150 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.380 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTER Port\u003c\/td\u003e\n\u003ctd\u003eRS485 Serial port for programming terminal or local HMI connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAUX Port\u003c\/td\u003e\n\u003ctd\u003eAuxiliary serial communication port for peripheral devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Slot A\u003c\/td\u003e\n\u003ctd\u003ePCMCIA memory extension slot (SRAM or Flash memory cards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Slot B\u003c\/td\u003e\n\u003ctd\u003ePCMCIA network\/fieldbus interface slot (Fipway, Modbus Plus, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Ensure the rack power supply is completely switched off before inserting or extracting the processor module from the backplane. Secure the module using the top and bottom chassis locking screws to guarantee reliable grounding to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling and Clearance:\u003c\/strong\u003e Maintain clear ventilation paths above and below the rack assembly. Allow at least 100 mm of clearance space from wire ducts or cabinet walls to promote natural convection cooling. Do not operate the unit in ambient environments exceeding 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e The processor grounds automatically through the backplane contacts. Verify that the TSXRKY rack frame is connected to the central functional earth bar of the enclosure using a low-impedance copper strap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e Replace the auxiliary memory backup battery while the PLC system remains powered up to prevent accidental data loss from volatile internal registers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required to configure and program this processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe processor is fully programmed, configured, and diagnosed using PL7 software versions supporting TSX 57 architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be hot-swapped while the rack is live?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module must be powered down. Always isolate the main rack power supply before inserting or removing the processor to prevent permanent hardware damage or unexpected system states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat purpose do the built-in PCMCIA slots serve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlot A accepts memory expansion cards to increase available program or data memory, while Slot B supports physical communication cards for connection to upstream architectures or industrial networks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573284715,"sku":"TSXP572623","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp572623-3na11yzfv0p.png?v=1776164292"},{"product_id":"schneider-electric-140cpu65150c-modicon-quantum-unity-processor","title":"Schneider Electric 140CPU65150C Modicon Quantum Unity Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-923\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e140CPU65150C (140-CPU-65150C)\u003c\/strong\u003e\u003cspan class=\"citation-923 citation-end-923\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Unity processor designed for the Modicon Quantum automation platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-922 citation-end-922\"\u003eFeaturing a 166 MHz clock speed and 768 KB of internal memory, this controller is engineered to handle complex logic, advanced floating-point calculations, and high-speed data processing in demanding industrial environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe \"C\" suffix denotes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion, providing enhanced protection against corrosive atmospheres (conformal coating), making it the gold standard for wastewater treatment, chemical processing, and harsh manufacturing plants. As a Phase-Out component, this processor remains vital for maintaining the operational continuity of legacy Unity Pro-based systems without requiring a full-scale migration to the M580 series.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-921 citation-end-921\"\u003eThis processor utilizes the Unity Pro (now EcoStruxure Control Expert) programming environment, supporting five IEC languages for maximum flexibility.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware architecture includes integrated communication ports and a high-speed internal bus interface. It is capable of managing extensive I\/O configurations and supports sophisticated redundancy schemes. The conformal coating applied to the internal PCBA ensures long-term reliability in environments where salt spray, moisture, or chemical vapors would typically cause premature failure in standard non-coated electronic assemblies.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140CPU65150C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eClock Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e166 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory (User)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e768 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coated (Harsh Environment)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.50 x 32.50 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgramming Software\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnity Pro \/ EcoStruxure Control Expert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"C\" in the 140CPU65150C model number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" indicates that the module is conformally coated.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-920 citation-end-920\"\u003eThis involves applying a thin polymeric film to the circuit board, which protects against moisture, dust, chemicals, and temperature extremes.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is essential for installations in \"harsh\" or \"corrosive\" environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a non-coated 140CPU65150 with this 140CPU65150C version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 140CPU65150C is a direct functional replacement for the standard 140CPU65150. It offers identical performance and programming compatibility but provides superior environmental resilience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this processor support Ethernet communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 140CPU65150C features integrated ports for local diagnostics and basic communication, but for high-capacity Ethernet\/IP or Modbus TCP networking across the plant, it is typically paired with a 140NOE series Ethernet module.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal memory is volatile and relies on a battery for data retention during power-off states. Always monitor the \"BAT\" LED indicator on the front panel. It is recommended to replace the battery every 12 to 24 months, even if the indicator is not yet active, to prevent losing the application program during a site power failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot Swapping Caution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the Modicon Quantum backplane supports \"Hot Swap\" for many I\/O modules, the CPU should never be removed or inserted while the backplane power supply is active. Doing so can cause electrical arcing or memory corruption. Always power down the rack before servicing the processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen deploying this CPU in a Hot Standby (Redundant) configuration, ensure that both the primary and standby 140CPU65150C units are running the exact same firmware version (OS). Incompatibilities in firmware versions will prevent the system from entering a healthy redundant state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573383019,"sku":"140CPU65150C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140cpu65150c-o2n5nnh5sjf.png?v=1776159527"},{"product_id":"schneider-tsxsay1000c-coated-as-interface-master-module","title":"Schneider TSXSAY1000C Coated AS-Interface Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized AS-Interface (AS-i) Master Module designed for the Schneider Electric Modicon Premium automation platform. This \"C\" version is characterized by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating (Humiseal 1A33)\u003c\/strong\u003e, which provides superior protection against moisture, dust, and chemical contaminants, making it ideal for harsh industrial environments. Operating as a bridge between the Modicon Premium rack and the AS-i cabling system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV2 standard and extended addressing\u003c\/strong\u003e, allowing for a highly flexible and scalable network of actuators and sensors. By simplifying field wiring into a single two-wire cable for both power and data, this module significantly reduces installation costs and improves diagnostic capabilities in complex automated systems such as bottling plants, conveyor networks, and specialized machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXSAY1000C is engineered for high-density networking and robust environmental performance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAS-i V2 Capabilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports the M2E profile, enabling the management of standard slaves as well as extended addressing slaves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlave Capacity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 31 slaves (Analog I\/O, Discrete 4I\/4O, or Safety interfaces).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 62 slaves (Discrete 4I\/3O), significantly increasing the network's point density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTreated with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHumiseal 1A33\u003c\/strong\u003e, ensuring long-term reliability in corrosive atmospheres or high-humidity zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHost Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowered directly via the Modicon Premium backplane (450 mA at 5 V DC), eliminating the need for external module power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Diversity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of interfacing with a variety of modules including safety-rated interfaces and analog I\/O units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Physical Layer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 3-way male SUB-D connector for secure and reliable connection to the AS-i bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXSAY1000C (Coated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAS-i Version\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV2 (Standard and Extended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e[AS-i] M2E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtective Treatment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Humiseal 1A33)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0…60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Modules (TSX574+)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 per base controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many modules can I install in a TSX57310 processor rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the TSX573 series, the system supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAS-i master modules per base controller. This allows for massive decentralized I\/O scaling within a single PLC project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"C\" designation in TSXSAY1000C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated\u003c\/strong\u003e. While the standard TSXSAY1000 is suitable for clean industrial environments, the TSXSAY1000C is designed for \"Harsh\" environments where airborne pollutants or humidity could otherwise cause short circuits or corrosion on the PCB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide power to the AS-i bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the module takes its own logic power (450 mA) from the Premium rack, the AS-i bus itself requires a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAS-i Power Supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(usually 30 V DC with integrated data decoupling) to power the field sensors and actuators.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAddressing and Commissioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen using extended addressing (V2), ensure that your slaves are also V2 compliant. Extended addressing divides the standard 31 addresses into \"A\" and \"B\" banks, allowing for 62 total devices. Use the local signaling display unit on the front of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto identify address conflicts or bus faults during the initial power-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and SUB-D Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3-way SUB-D connector is the primary gateway to the AS-i bus. Use high-quality, shielded AS-i yellow flat cable for the field run. Ensure that the total cable length does not exceed 100 meters without the use of AS-i repeaters. Even with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHumiseal 1A33 coating\u003c\/strong\u003e, ensure the SUB-D connector is firmly tightened to maintain a gas-tight seal at the connection point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 rating means the module must be installed in an enclosure. Because this is the coated version, it is specifically intended for cabinets located in \"Class 3C2\" or similar environments. Maintain a vertical mounting orientation to facilitate natural convection, as the module consumes nearly 2.25 Watts of power from the backplane, which must be dissipated to stay within the 0…60 °C operating range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573809003,"sku":"TSXSAY1000C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxsay1000c-qe1acipseoe.png?v=1776164526"},{"product_id":"140xsm00200-schneider-electric-modicon-quantum-16-switch-input-simulator","title":"140XSM00200 Schneider Electric Modicon Quantum 16-Switch Input Simulator","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XSM00200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized diagnostic and commissioning tool within the Schneider Electric Modicon Quantum automation platform. Designed as a high-utility accessory, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDiscrete Input Simulator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 16 integrated manual switches that allow engineers to simulate real-world field signals without the need for external wiring or sensors.\u003c\/p\u003e\n\u003cp\u003eBy plugging directly into the front of specific Quantum discrete input modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XSM00200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables precise logic validation and Factory Acceptance Testing (FAT). It is an essential component for debugging complex PLC code, verifying interlock sequences, and training operators in a risk-free environment. This \"dry-run\" capability ensures that automation logic is fully vetted before the system is connected to live industrial machinery, significantly reducing the risk of equipment damage during startup.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 140XSM00200 is engineered for seamless mechanical and functional integration with the Quantum I\/O lineup:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Simulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides 16 independent toggle switches, allowing for the simultaneous simulation of a full 16-point input module's data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to interface with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DAI54000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(115 VAC) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DAI74000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(230 VAC) discrete input modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Hardware Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMounts directly onto the front connector of the target I\/O module, overriding field inputs to provide manual control to the technician.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNo External Power Required:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe simulator utilizes the internal logic of the module it is connected to, requiring no additional external power source for signal injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe manual switch positions provide an immediate physical reference for the state of each input bit, mirroring the status LEDs on the host module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140XSM00200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input Simulator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Switches\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140DAI54000, 140DAI74000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Logic Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual Toggle Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (US)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.51 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e00785901652083\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 140XSM00200 require separate software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The PLC CPU treats the simulator exactly like the field signals it replaces. In your programming environment (Unity Pro\/Control Expert), you simply monitor the discrete input registers associated with the slot where the host module is installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this simulator on 24 V DC modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePer the manufacturer's specifications, the 140XSM00200 is primarily listed for compatibility with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DAI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(AC) series modules. Always verify the connector pinout and voltage rating of the host module before installation to ensure safe operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to leave the simulator installed during normal production?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the simulator is robust, it is intended for testing and maintenance. In a production environment, it should be removed and replaced with actual field wiring to ensure the PLC is receiving real-time data from the process sensors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTesting and Debugging Workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo use the simulator, remove the field wiring connector from the front of your 140DAI module and snap the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XSM00200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto place. This allows you to \"walk\" through a sequence—for example, toggling Switch 1 for a \"Pump Start\" command and Switch 2 for \"Flow Confirmed\"—to ensure the PLC logic initiates the correct subsequent actions. This is the fastest way to identify \"race conditions\" or logic errors in complex code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator is designed to be user-friendly. When attaching it to a Quantum discrete I\/O module, ensure the pins are correctly aligned with the module's front terminal block. Apply even pressure until the unit is fully seated. Because this is often a US-made component (Country of Origin: US), it adheres to rigorous mechanical tolerances designed for the Quantum \"RAK\" system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage and Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the 140XSM00200 is a diagnostic tool that may not be used every day, store it in an anti-static bag in a clean, dry environment. Periodically cycle the 16 switches while the unit is disconnected to ensure no oxidation builds up on the contacts, which could lead to intermittent signals during your next testing cycle.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573841771,"sku":"140XSM00200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140xsm00200-5un4u2an4nr.png?v=1776159665"},{"product_id":"schneider-electric-tsxmfpp512k-modicon-premium-flash-eprom-memory","title":"Schneider Electric TSXMFPP512K Modicon Premium Flash EPROM Memory","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXMFPP512K (TSXMFPP512K)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 512 KB Flash EPROM application memory extension card engineered specifically for the Schneider Electric Modicon Premium processor range. This PCMCIA-style memory card serves as a non-volatile storage solution for PLC user programs, symbols, and data constants. By offloading the application logic from volatile RAM to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXMFPP512K\u003c\/strong\u003e, industrial operators ensure that critical control code is preserved even in the event of total power loss or battery failure.\u003c\/p\u003e\n\u003cp\u003eHoused in a compact, ruggedized format, this memory extension is a cornerstone for automation reliability in sectors such as automotive manufacturing, water treatment, and infrastructure management. As a phase-out component, it remains a vital asset for maintaining the longevity of existing Modicon Premium installations and preventing costly system re-engineering.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXMFPP512K is designed for seamless hardware integration and high data integrity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes Flash EPROM technology, allowing for reliable long-term storage without the need for an internal battery for data retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e512 KB Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for standard-to-mid-sized Modicon Premium applications, providing ample space for logic rungs, functional blocks, and system configuration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to fit into the dedicated PCMCIA slot on Modicon Premium TSX57 series processors, enabling rapid memory expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically backs up the application, allowing the processor to perform an automatic \"Warm Start\" or \"Cold Start\" from the Flash card after a power interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand the thermal and electromagnetic stresses common in high-density control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXMFPP512K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlash EPROM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 x 13 x 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor Memory Extension\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TSXMFPP512K be used to store data logs or trends?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlash EPROM memory is primarily designed for the application program (code) and system constants. While it provides non-volatile storage, frequent write operations—like high-speed data logging—are better suited for SRAM cards or specialized data storage modules due to the limited write cycles inherent in Flash technology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to insert the memory card while the PLC is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile many PCMCIA cards are designed for rugged use, it is a recommended engineering practice to power down the processor before inserting or removing the TSXMFPP512K. This prevents potential file corruption or electrical transients during the hardware handshake.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the processor RAM and the Flash card contain different programs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a standard configuration, the processor can be set to prioritize the Flash EPROM. Upon power-up, if the processor detects a valid program on the TSXMFPP512K, it will typically load that program into the working RAM, ensuring the machine operates with the verified \"Master\" version of the code.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWrite Protection and Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TSXMFPP512K often features a physical write-protect switch or software-level locking. Once the final commissioning of a project is complete, engineers should enable write protection. This prevents accidental overwriting of the logic by unauthorized users and ensures the integrity of the \"Golden Copy\" of the automation program.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHandling and Static Prevention\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe edge connectors on the PCMCIA card are sensitive to electrostatic discharge (ESD) and contamination. Always handle the card by its edges and avoid touching the gold-plated pins. If the environment is particularly dusty or humid, ensure the processor's slot cover is securely closed after the card is seated to prevent contact oxidation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase-Out Lifecycle Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the Modicon Premium range and its associated memory cards like the TSXMFPP512K are in a phase-out status, it is critical to perform regular backups of the Flash contents to a digital repository. In the event of a physical card failure, having a verified file ready for download to a replacement card is the fastest way to restore production.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573972843,"sku":"TSXMFPP512K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxmfpp512k-mcs4iilgtfn.png?v=1776164150"},{"product_id":"171ccs78000-schneider-electric-modicon-momentum-m1-processor-adapter","title":"171CCS78000 Schneider Electric Modicon Momentum M1 Processor Adapter","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e171CCS78000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance M1 Processor Adapter within the Schneider Electric Modicon Momentum family, engineered to provide centralized intelligence for distributed I\/O topologies. Operating at a clock speed of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 MHz\u003c\/strong\u003e, this processor adapter is designed to snap onto any Momentum I\/O base, transforming a simple I\/O block into a fully functional, programmable logic controller (PLC).\u003c\/p\u003e\n\u003cp\u003eFeaturing dual Modbus communication ports, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e171CCS78000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in multi-device networking, allowing for simultaneous communication with HMI panels, variable speed drives, or supervisory systems. Primarily deployed in manufacturing, water wastewater, and material handling, this module is a critical asset for maintaining legacy industrial systems. Although in its phase-out stage, its proven reliability and deterministic control capabilities make it a vital component for facility managers looking to sustain existing automation footprints without expensive re-engineering.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 171CCS78000 serves as the core \"brain\" for the modular Momentum platform, integrating processing power with flexible networking:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Modbus Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with two independent Modbus RS485 ports, facilitating efficient data exchange and peer-to-peer networking in complex architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20 MHz Processing Core:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivers sufficient computational speed for medium-complexity logic, PID loops, and rapid I\/O refreshing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular \"Snap-On\" Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for a backplane; the adapter mounts directly onto I\/O bases, significantly reducing cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Programming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Schneider Electric legacy programming software, ensuring seamless logic integration for existing Momentum users.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact dimensions and a lightweight design (0.22 kg) allow for high-density mounting in small enclosures or distributed junction boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e171CCS78000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Momentum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Modbus RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM1 Processor Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out (Legacy Support Available)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 x 26 x 6 (Packaged)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 171CCS78000 be used as a standalone controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when snapped onto a Momentum I\/O base, it functions as a standalone PLC. It does not require a separate rack or power supply module, as it draws power through the I\/O base unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length for the Modbus ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the RS485 Modbus ports, the maximum segment length is 1200 meters (approx. 4000 feet) without a repeater, provided that high-quality shielded twisted-pair cable is used and properly terminated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a direct replacement for this phase-out module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile Schneider Electric has moved toward the Modicon M221\/M241 series, there is no direct \"snap-on\" replacement that fits the Momentum I\/O bases. Maintaining a stock of 171CCS78000 units is the most cost-effective way to support existing Momentum installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Port Wiring and Biasing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen utilizing both Modbus ports, ensure that the network is correctly biased and terminated with 120 Ohm resistors at the physical ends of the trunk. Improper termination on a 20 MHz processor system can lead to intermittent CRC errors and \"Module Health\" alarms. For noise-heavy environments, always use shielded cables and ground the shield at a single point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal and Mounting Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 171CCS78000 mounts directly onto the I\/O base, it relies on the base for structural integrity. Ensure the locking tabs are fully engaged. In high-vibration applications, we recommend additional DIN rail anchors on both sides of the combined assembly. Avoid installing the module in areas with direct sunlight or near high-heat sources, as excessive heat can degrade the 20 MHz oscillator's accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a legacy M1 adapter, ensure the internal battery or capacitor backup is checked during routine maintenance. If the module is powered down for extended periods without a viable battery, the user program may be lost, requiring a re-download from the original source files.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574005611,"sku":"171CCS78000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/171ccs78000-3lkoukfos1u.png?v=1776159768"},{"product_id":"tsxp57153mc-schneider-electric-modicon-premium-pl7-processor","title":"TSXP57153MC Schneider Electric Modicon Premium PL7 Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57153MC \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, single-format processor belonging to the Schneider Electric Modicon Premium range. Engineered for high-speed industrial logic, this CPU is optimized for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePL7 programming environment\u003c\/strong\u003e, providing a robust solution for medium-to-large scale automation tasks. Operating with a current consumption of 530 mA at 5 V DC, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57153MC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers the deterministic control required for synchronized manufacturing lines, material handling systems, and complex process regulation. Its single-slot format allows for high-density configuration within the Premium rack, maximizing the efficiency of your control cabinet footprint. As a phase-out component, this processor is a critical legacy asset for maintenance teams tasked with sustaining existing infrastructure and ensuring operational continuity without the immediate need for a total system migration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXP57153MC is designed to function as the central intelligence of a modular automation system:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically tuned for PL7 software (Junior\/Pro), supporting a wide array of functional blocks, PID control, and floating-point arithmetic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized internal circuitry drawing 530 mA from the rack's 5 V DC backplane, ensuring low thermal dissipation and stable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures integrated ports for Ter\/Aux communication and is compatible with various PCMCIA cards for Modbus, FIPway, or Ethernet connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of managing thousands of discrete and analog I\/O points across local and remote racks (via X-Bus or FIPIO).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand industrial vibration and electromagnetic interference, weighing a solid 0.61 kg to ensure mechanical stability within the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXP57153MC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePL7 Junior \/ PL7 Pro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e530 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-Slot (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out (Legacy Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.61 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.00 x 26.00 x 9.50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85371099\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXP57153MC compatible with Unity Pro (EcoStruxure Control Expert)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"MC\" designation and its lineage are primarily associated with the PL7 software environment. While some Premium processors can be migrated to Unity Pro, the TSXP57153MC is best utilized as a direct replacement for existing PL7-programmed systems to ensure 100% logic and communication compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this processor include internal memory, or do I need a PCMCIA card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit includes internal RAM for execution, but for non-volatile application storage and backup, a compatible PCMCIA memory card (such as a TSXMRPC or TSXMFPP series) is highly recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a \"HALT\" light on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA \"HALT\" LED typically indicates a blocking system error or a watchdog timeout. This can be caused by a software loop error, hardware incompatibility, or a failed I\/O module on the bus. Connecting with PL7 software is required to read the system diagnostic buffer for the specific error code.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRack Installation and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen inserting the TSXP57153MC into a TSXRKY series rack, ensure the power supply is switched off. The single-slot module must be fully seated into the backplane connector before the top and bottom securing screws are tightened. Ensure the rack's grounding terminal is connected to a low-impedance earth bus to protect the 530 mA internal circuitry from high-frequency noise and transients.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMemory and Battery Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TSXP57153MC relies on an internal battery (typically located in the power supply module or the CPU itself depending on the version) to maintain the RAM contents during power-off periods. Since this is a legacy phase-out product, we recommend replacing the battery every 2 years and maintaining a current \"Golden Copy\" of the PL7 application on an external Flash PCMCIA card to prevent data loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Port Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Ter and Aux ports utilize non-isolated RS485 signals. When connecting a PC for programming or an HMI, always use the recommended Schneider Electric shielded cables (e.g., TSXPCX1031). Avoid \"hot-plugging\" communication cables in environments with high potential differences between equipment grounds to prevent damage to the CPU's communication driver.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574071147,"sku":"TSXP57153MC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp57153mc-53g1tlrmgzy.png?v=1776164256"},{"product_id":"schneider-tsxpsi2010-modicon-premium-atrium-power-supply-module","title":"Schneider TSXPSI2010 Modicon Premium Atrium Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized 24 VDC power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAtrium slot PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. Specifically designed for \"Atrium slot PLC Unity\" configurations, this module provides the critical voltage stabilization and current regulation required to power Atrium processors residing in PC-based automation slots. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a robust electrical interface, shielding sensitive PLC logic from the electrical noise and fluctuations inherent in industrial PC power buses. With a high inrush current tolerance and integrated short-circuit protection via a 2 A time-delay fuse, it ensures that the control system remains operational in demanding environments such as automotive assembly, material handling, and complex machine control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware architecture is built for precision power delivery and system safety:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a nominal 24 VDC input with a wide tolerance band (19.2 V to 30 V), accommodating standard industrial battery or rectified power sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMicrobreak Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned with internal capacitance to bridge voltage dips of up to 7 ms, preventing system resets during brief power interruptions or supply switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures specialized electrical interfaces including one female\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUB-D 9\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector and one female\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUB-D 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector dedicated to the supply voltage input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an internal 2 A time-delay fuse to protect against overcurrent and short-circuits, alongside high immunity to inrush currents (100 A at 25 deg C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtrium Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eForm-factored to integrate seamlessly with Atrium slot PLC architectures, providing the \"Unity\" compatible power layer for PC-integrated safety and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXPSI2010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium \/ Atrium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2 to 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 1.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A at 25 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A Fuse (Time Delay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSUB-D 9 and SUB-D 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAltitude Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 2000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXPSI2010 compatible with standard Modicon Premium RKY racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model is designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAtrium slot PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Standard Modicon Premium racks typically use the TSXPSY series (e.g., TSXPSY2600). The TSXPSI2010 is intended for the PC-based slot-PLC versions of the Modicon architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle brief power losses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has an immunity to microbreaks of up to 7 ms at 24 V. If the supply voltage drops for a duration shorter than this, the internal energy storage maintains the processor's operation without a system halt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cabling is required for the SUB-D 3 connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SUB-D 3 connector is used for the primary 24 VDC supply input. It is critical to use properly shielded, twisted-pair cabling to minimize EMI and ensure that the \"Unity\" software diagnostics for power health remain accurate.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen sizing your 24 VDC bulk power supply, account for the 100 A inrush current of the TSXPSI2010. While this spike lasts only milliseconds (3 A²s), a power supply with overly sensitive \"electronic fuse\" trip settings may fail to start.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the industrial PC or enclosure housing the Atrium slot PLC has adequate airflow. The TSXPSI2010 is rated for operation up to 60 deg C; however, if the PC's internal ambient temperature exceeds this due to high CPU load, the power supply module's lifespan may be reduced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SUB-D connectors must be securely tightened to the chassis. The metal shell of the SUB-D connector provides the necessary path to ground for electromagnetic interference. A loose connector can lead to intermittent \"I\/O Fault\" or \"Power Supply Fault\" LEDs on the Atrium processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the module fails to power up, check the internal 2 A time-delay fuse. Always replace it with an identical rating (IEC 1131-2 compliant) to maintain the safety certification and protective characteristics of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574169451,"sku":"TSXPSI2010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpsi2010-vcvnyoydkty.png?v=1776164428"},{"product_id":"schneider-ls1d253a65-tesys-fuse-disconnector-body-3p-25a","title":"Schneider LS1D253A65 TeSys Fuse Disconnector Body (3P, 25A)","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eLS1D253A65\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003eis a robust 3-pole fuse-disconnector body from the Schneider Electric\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTeSys LS1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erange.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis high-reliability isolation device is specifically designed for the protection and manual disconnection of industrial electrical circuits.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt accommodates\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e10 x 38 mm NFC\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efuses (AM or GG types) and features an integrated signaling circuit with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e2 C\/O early-break auxiliary contacts\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThese auxiliary contacts provide essential feedback to control systems or safety interlocking circuits before the main power poles open.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for extreme environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe LS1D253A65 operates in temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e-50 to 70 deg C\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it an ideal choice for outdoor control panels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erefrigeration systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand heavy-duty industrial motor protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eLS1D253A65\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built for high-performance circuit isolation and safety signaling:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e3-Pole Isolation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides simultaneous disconnection of all three phases in a compact 94 mm width footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEarly-Break Contacts:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 2 C\/O (Changeover) early-break auxiliary contacts.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThese contacts toggle before the main power circuit opens,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing the control system to safely ramp down loads or trigger alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFuse Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for standard 10 x 38 mm NFC fuses,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting both motor-rated (AM) and general-purpose (GG) fuse links.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMechanical Operation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a high-visibility toggle control for manual operation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith a mounting tolerance of +\/- 23 degrees from the vertical position.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh Voltage Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRated for operational voltages up to 690 V AC for the power circuit and 500 V AC \/ 440 V DC for the signaling circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLS1D253A65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (TeSys)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3P (3 Poles)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFuse Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 x 38 mm (NFC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 A (Power) \/ 10 A (Signaling)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690 V AC (Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 C\/O Early-Break\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-50 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 mm x 94 mm x 84 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of \"Early-Break\" auxiliary contacts in this device?\u003c\/strong\u003eEarly-break contacts are a safety feature. They change state slightly before the main poles disconnect. This allows a PLC or safety relay to detect the disconnection intent and electronically shut down sensitive components (like variable speed drives or motor contactors) to prevent arcing across the main disconnector poles under load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this disconnector for DC power circuits?\u003c\/strong\u003eThe power circuit rating is specified for 690 V AC. While the signaling circuit is rated for 440 V DC, using the main poles for high-current DC disconnection requires specific de-rating and verification of the arc-extinguishing capabilities for DC. It is primarily intended for AC motor and distribution circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit come with fuses included?\u003c\/strong\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLS1D253A65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a fuse-disconnector\u003cspan\u003e \u003c\/span\u003e\u003cem\u003ebody\u003c\/em\u003e. The 10 x 38 mm fuses must be selected and purchased separately based on the specific current and protection characteristics (AM or GG) required for your load.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-221\"\u003e\u003c\/span\u003e\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e\u003cspan class=\"citation-221 citation-end-221\"\u003e\u003cspan\u003e \u003c\/span\u003eThe device is designed for vertical mounting on a standard 35 mm DIN rail.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the mounting position stays within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+\/- 23 degree\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etolerance to ensure the mechanical toggle operates correctly and the fuse carriers remain secure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring the Signaling Circuit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the 2 C\/O auxiliary contacts to interlock the disconnector with your upstream contactor. This ensures that the circuit is de-energized by a contactor capable of breaking the full load current before the manual disconnector is opened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"TH\" protective treatment makes this device suitable for humid environments. However, in extreme cold (-50 deg C), ensure the toggle is operated slowly to prevent mechanical stress on the housing until the internal cabinet temperature stabilizes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure fuses are fully seated in the carrier before closing the toggle. A loose fuse can cause localized heating and high resistance, leading to premature failure of the terminal base or the fuse itself.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574234987,"sku":"LS1D253A65","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ls1d253a65-mgkxzdwitmi.png?v=1776163251"},{"product_id":"schneider-modicon-premium-tsxp57024m-processor","title":"Schneider Modicon Premium TSXP57024M Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a standard-format processor within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform, engineered for high-speed industrial control and flexible distributed I\/O management. Positioned as a versatile mid-range CPU, it provides a discrete I\/O capacity of up to 1024 points and supports up to 80 analog channels. Its architecture is optimized for mid-to-large scale applications in manufacturing, water treatment, and infrastructure, offering a deterministic execution environment with 48 Kwords of internal memory. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in communication versatility, featuring integrated terminal and auxiliary ports for HMI or programming access, alongside a PCMCIA slot for high-level fieldbus integration like Modbus+, FIPIO, or RS 485.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is designed for modular scalability and high-performance processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 48 Kwords of internal memory (K16), with support for extension memory up to 128 Kwords via PCMCIA cards for extensive data logging and complex logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManages up to 16 racks (4\/6\/8-slot) or 8 racks (12-slot), providing access to a total of 96 physical module slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two 8-pin mini-DIN connectors (non-isolated RS 485):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTER Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupplies 5V for FTX terminals or PCs; defaults to UNI-TELWAY master at 19200 bauds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAUX Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated for MMI (Man-Machine Interface) or printers; does not supply power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecific Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 24 application-specific channels (e.g., high-speed counting or motion) and up to 4 AS-i bus masters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCMCIA Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front-panel Type 3 slot accepts multiprotocol cards including TSX SCP 111 (RS 232), TSX MBP 100 (Modbus+), and TSX MDM 10 (Modem).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXP57024M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1024 In-rack I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 In-rack I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 Kwords (K16)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTER and AUX (RS 485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard (Single-slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-TELWAY, ASCII, FIPIO, Modbus+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn which slot should I install the TSXP57024M standard format processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe installation position depends on your power supply. If using a standard power supply (TSX PSY 1610\/2600), the processor is preferred in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eposition 00\u003c\/strong\u003e. If using a double-format power supply (TSX PSY 3610\/5500), the processor must be installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eposition 01\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the TER and AUX ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both are RS 485 mini-DIN connectors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTER port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 5V power to peripheral devices like handheld terminals or RS-232\/485 converters. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAUX port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis strictly for data and is typically used for HMI or printers that have their own power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap the PCMCIA communication card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The documentation strictly mandates that the processor must be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOWERED DOWN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprior to inserting or removing any PCMCIA communication or memory card to prevent electronic damage or system crashes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Mounting Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003c\/strong\u003e, ensure the locking levers are fully clicked into place. The rack power supply must always be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOWERED DOWN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring insertion to avoid arcing across the backplane pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf your application requires more than 48 Kwords, utilize the PCMCIA extension slot. Always verify the battery status of the PCMCIA card (if applicable) to ensure data persistence during a system power cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing for Mini-DIN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TER and AUX ports use fragile 8-pin connectors. Use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSX P ACC 01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolation box for long-distance UNI-TELWAY connections to provide surge protection and signal isolation between the PLC and the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and Thermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the rack horizontally to allow for natural heat convection. Maintain at least 100 mm of clearance above and below the module to keep the operating temperature within the rated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 60 deg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574267755,"sku":"TSXP57024M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp57024m-qkxl0wlhqhs.png?v=1776164236"},{"product_id":"schneider-electric-atv212wu22n4c-altivar-212-variable-frequency-drive","title":"Schneider Electric ATV212WU22N4C Altivar 212 Variable Frequency Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-906\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eATV212WU22N4C (ATV212WU22N4C)\u003c\/strong\u003e\u003cspan class=\"citation-906 citation-end-906\"\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated HVAC variable frequency drive (VFD) optimized for pumping, ventilation, and air conditioning applications.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-905 citation-end-905\"\u003eEngineered for high-reliability performance in building management systems (BMS), this 2.2 kW controller operates at 480 V (3-phase) and features an integrated EMC Class C1 filter to minimize electromagnetic interference.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-904\"\u003eWith its robust\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIP55\u003c\/strong\u003e\u003cspan class=\"citation-904 citation-end-904\"\u003e\u003cspan\u003e \u003c\/span\u003eprotection rating, the unit is designed for decentralized installation outside of electrical cabinets, providing superior resistance against dust and water jets.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis drive is a critical component for facility managers looking to reduce energy consumption by up to 70% while maintaining precise control over flow and pressure in commercial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-903 citation-end-903\"\u003eThe Altivar 212 architecture is focused on \"Eco-Design\" and seamless integration into building automation networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt eliminates the need for additional harmonic filters in most applications due to its reduced capacitance technology, which limits current distortion to less than 35% THD(i). The drive supports multi-protocol communication, including Modbus, METASYS N2, APOGEE FLN, and BACnet as standard. Its IP55 enclosure is specifically thermal-mapped to ensure high-efficiency cooling without the need for external ventilation, making it ideal for rooftop or mechanical room deployments where space and protection are paramount.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATV212WU22N4C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar 212\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kW (3 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-480 V (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP55 \/ UL Type 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass C1 (Integrated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.26 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.5 x 25.5 x 28.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus, BACnet, METASYS N2, APOGEE FLN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to +40 deg C (up to 50 deg C with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ATV212WU22N4C require an external enclosure for outdoor use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the IP55 rating indicates the drive is protected against dust ingress and low-pressure water jets from any direction. It can be mounted directly on the wall or machine frame, provided it is shielded from direct sunlight and extreme precipitation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the Altivar 212 and the Altivar 320 or 630?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-902 citation-end-902\"\u003eThe Altivar 212 is specifically \"HVAC-optimized.\"\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-901 citation-end-901\"\u003eIt lacks the high-torque features required for heavy industrial machinery (like conveyors) but includes specialized software functions for fans and pumps, such as \"Fire Mode,\" \"Sleep\/Wake,\" and \"Damper Control.\"\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used with single-phase input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the ATV212WU22N4C is strictly designed for 3-phase input. Attempting to run the drive on single-phase power will result in an input phase loss fault (PHF) and may damage the DC bus capacitors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard industrial drives, the ATV212 utilizes a specialized DC bus design that inherently reduces harmonics. You generally do not need to install line reactors to meet IEEE 519 standards in building applications, which saves significant installation space and cost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the EMC Class C1 rating, use shielded motor cables. Ensure the shield is bonded 360 degrees to the drive's grounding plate. For IP55 units, use appropriate liquid-tight cable glands to maintain the enclosure's integrity at the entry points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEven with an IP55 rating, thermal management is vital. Maintain at least 10 cm of vertical clearance above and below the unit. If mounting multiple drives side-by-side, ensure a minimum horizontal gap of 5 cm to allow for natural convection cooling across the heat sink fins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574529899,"sku":"ATV212WU22N4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv212wu22n4c-zaei55mg52t.png?v=1776162217"},{"product_id":"schneider-170adm69051-modicon-momentum-discrete-i-o-base-10i-8o","title":"Schneider 170ADM69051 Modicon Momentum Discrete I\/O Base (10I\/8O)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-110\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-110\"\u003eis a high-performance discrete triac I\/O base within the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eModicon Momentum\u003c\/strong\u003e\u003cspan class=\"citation-110 citation-end-110\"\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-109\"\u003eDesigned for distributed control architectures, this module features a 120 V AC interface with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e10 inputs\u003c\/strong\u003e\u003cspan class=\"citation-109\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8 triac outputs\u003c\/strong\u003e\u003cspan class=\"citation-109 citation-end-109\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-108 citation-end-108\"\u003eThe Momentum platform’s unique modular design allows this base to be paired with various communication adapters (Ethernet, Modbus, Profibus) or a processor adapter, making it a highly versatile solution for decentralized automation.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWith its solid-state triac outputs and robust 120 V AC logic, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for controlling AC loads such as solenoids, contactors, and motor starters in HVAC, water treatment, and manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-107\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e\u003cspan class=\"citation-107 citation-end-107\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for industrial-grade AC switching and signal processing:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-106\"\u003e\u003c\/span\u003e\u003cstrong\u003eI\/O Density:\u003c\/strong\u003e\u003cspan class=\"citation-106 citation-end-106\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigured with one group of 10 digital inputs (IEC 1131-2 Type 2) and one group of 8 digital triac outputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePositive logic with a 120 V AC nominal rating. It features a high guaranteed \"On\" state voltage (\u0026gt; 74 V) to ensure immunity against induced electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-State Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriac-based outputs provide long-cycle life compared to mechanical relays, supporting a high operating rate of up to 3,000 cycles per hour.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-105\"\u003e\u003c\/span\u003e\u003cstrong\u003eInternal Protection:\u003c\/strong\u003e\u003cspan class=\"citation-105 citation-end-105\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with two internal 2.5 A slow-blow fuses to protect the module from overcurrent conditions in the output groups.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a high dielectric strength of 1780 V AC between the field channels and the internal communication bus to safeguard the controller electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170ADM69051\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Momentum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 V AC (74...132 V range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriac (Solid State)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per point (4 A total per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2 line cycle (approx. 8ms at 60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 W to 8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e141.5 mm x 125 mm x 47.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of a Triac output over a relay output for the 170ADM69051?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-104 citation-end-104\"\u003eTriacs are solid-state devices with no moving parts.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThey are preferred for high-frequency switching (up to 3000 cyc\/h) because they do not suffer from contact wear or arcing, which significantly extends the life of the module in repetitive industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle 24 V DC signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-103\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e\u003cspan class=\"citation-103 citation-end-103\"\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for 120 V AC voltage levels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUsing DC voltage on the inputs or outputs will lead to a failure to switch (in the case of Triacs) or incorrect signal states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if an output is short-circuited?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-102 citation-end-102\"\u003eThe module contains internal 2.5 A slow-blow fuses.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of an overcurrent or short circuit that exceeds the rating, the fuse will blow to protect the internal circuitry. Note that these fuses protect groups of outputs rather than individual points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriac outputs require a minimum holding current to stay in the \"On\" state. For the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e, ensure your load draws at least 30 mA. If using very small pilot lights or high-impedance relays, a bleeder resistor may be required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLeakage Current Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-state outputs have a small leakage current (\u0026lt; 1.3 mA at 120 V) when in the \"Off\" state. Verify that your field device will not remain energized or \"ghost\" due to this leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Momentum base should be snapped securely onto a 35 mm DIN rail. Ensure the grounding leaf spring on the back of the module makes clean contact with the metal rail to ensure proper EMC performance and ESD resistance (up to 8 kV air discharge).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen operating at the maximum current of 4 A per module at 60 deg C, ensure adequate cabinet ventilation. The module dissipates up to 8 W of heat; vertical mounting is recommended to facilitate natural convection through the cooling vents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574562667,"sku":"170ADM69051","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/170adm69051-alti2czhxth.png?v=1776159707"},{"product_id":"schneider-tsxp57303amc-modicon-premium-double-format-pl7-processor","title":"Schneider TSXP57303AMC Modicon Premium Double-Format PL7 Processor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTSXP57303AMC\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a high-performance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edouble-format processor belonging to the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eModicon Premium\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for mid-to-high complexity industrial applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis processor utilizes\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePL7 Junior\/Pro\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esoftware to manage sophisticated control logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith a robust discrete I\/O capacity of up to 1024 points and specialized support for up to 45 process control loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TSXP57303AMC is a staple in sectors like water treatment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efood and beverage,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand infrastructure management.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"double-format\" module occupies two slots on the Premium rack,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the necessary hardware overhead for high-speed Boolean execution (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e12 µs) and extensive network connectivity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding support for CANopen,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAS-Interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand multiple fieldbus modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTSXP57303AMC\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for versatility and rapid processing in distributed architectures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMemory Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures 64 Kwords of internal RAM for program and data.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMemory is expandable via PCMCIA cards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting up to 384 Kwords for programs and 2688 Kwords for additional data storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMultitasking Capability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports an advanced application structure consisting of one master task,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eone fast task,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 64 event-triggered tasks for prioritized response to critical field signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Communication:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a non-isolated serial link (Mini-DIN) supporting speeds up to 115 kbit\/s.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt can manage up to 3 network modules and 2 fieldbus modules simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePerformance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDelivers high-speed instruction execution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereaching up to 6.\u003c\/span\u003e\u003cspan class=\"\"\u003e57 Kinst\/ms for 100% Boolean logic without an external PCMCIA card.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic LEDs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with local signaling for system status:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eRUN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e(Green),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eI\/O\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efault (Red),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eERR\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esystem fault (Red),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTER\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eterminal port activity (Yellow).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXP57303AMC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePL7 Junior \/ PL7 Pro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1024 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Time (Boolean)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 µs (Internal RAM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 mA at 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDouble-format (occupies 2 slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg (1.15 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes the TSXP57303AMC require a battery for memory retention?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe processor uses internal RAM which requires a backup battery (typically located in the rack power supply or on the processor itself) to retain the program and data object areas (%MW) during power outages.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor permanent storage,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ea PCMCIA Flash memory card is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use Unity Pro \/ EcoStruxure Control Expert with this processor?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTSXP57303AMC\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePL7\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esoftware environment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile some Modicon Premium processors can be upgraded to Unity Pro,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis specific AMC variant is optimized for legacy PL7 Junior and Pro applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the maximum number of racks this processor can manage?\u003c\/strong\u003e\u003cspan class=\"\"\u003eIt can support up to 16 racks if using 4,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor 8-slot configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor up to 8 racks when using 12-slot racks,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for a total of 128 slots across the architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSlot Placement:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs a double-format module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TSXP57303AMC must be placed in the first two slots of the TSXRKY rack (Slots 0 and 1).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the rack power supply (TSXPSY) is rated to handle the 1000 mA draw of the processor plus all associated I\/O modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the 0 to 60 deg C operating range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensure a minimum clearance of 100 mm above and below the rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe processor is treated with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHumiseal 1A33 conformal coating\u003c\/strong\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e providing enhanced resistance to humidity and chemical contaminants (Pollution Degree 2).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCMCIA Card Handling:\u003c\/strong\u003e\u003cspan\u003e Only insert or remove PCMCIA memory or communication cards when the processor is powered down or in a \"STOP\" state to avoid data corruption.\u003c\/span\u003e\u003cspan\u003e Ensure the locking latch is fully engaged to prevent vibration-induced disconnects.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e Ensure the TSXRKY rack is bonded to a low-impedance functional earth.\u003c\/span\u003e\u003cspan\u003e The processor's shielding and noise immunity depend heavily on the integrity of the rack's grounding strip.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574595435,"sku":"TSXP57303AMC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp57303amc-vupvaloc0zk.png?v=1776164316"},{"product_id":"schneider-170xts00200-modicon-momentum-quantum-spring-terminal-block","title":"Schneider 170XTS00200 Modicon Momentum\/Quantum Spring Terminal Block","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200 (170XTS00200)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance spring-type terminal block accessory designed for the Schneider Electric Modicon Momentum and Modicon Quantum automation platforms.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a primary connection interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis terminal block enables the rapid and secure integration of field wiring with discrete and analog I\/O bases.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing advanced spring-clamping technology,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the risk of terminal loosening caused by industrial vibration or thermal expansion—common issues with traditional screw-type connectors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis reliability makes it an essential component for critical infrastructure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eautomotive assembly lines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand high-vibration power generation environments where maintaining electrical continuity is vital for system uptime.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for high-density wiring and long-term mechanical stability:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSpring Terminal Technology:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides a constant,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaintenance-free clamping force on field conductors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reducing commissioning time compared to screw terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCompatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with both Modicon Momentum I\/O bases and Modicon Quantum automation platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModular Composition:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupplied as a kit containing three connectors arranged in a single row,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eperfectly aligned for high-density I\/O modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConnection Versatility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports a wide range of wire gauges,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eaccommodating single conductors up to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm² or dual-conductor configurations up to 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm².\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConstructed from heavy-duty,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflame-retardant materials designed to withstand the rigors of control cabinet environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170XTS00200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpring Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpring Clamping \/ Tool-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Momentum \/ Modicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Destination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete and Analog I\/O Bases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClamping Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 2.5 mm² to 2 x 1.5 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKit Composition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Connectors in one row\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95.000 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxL)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 mm x 16 mm x 90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 Months\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat are the primary benefits of using spring terminals over screw terminals?\u003c\/strong\u003e\u003cspan class=\"\"\u003eSpring terminals provide superior vibration resistance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile screw terminals can back out over time due to mechanical harmonics,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe spring mechanism in the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eapplies constant pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring a gas-tight connection that never requires re-torquing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIs this terminal block compatible with third-party I\/O modules?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan\u003e is specifically keyed and dimensioned for Schneider Electric’s Modicon Momentum and Quantum series I\/O bases.\u003c\/span\u003e\u003cspan\u003e Using it with non-compliant hardware may lead to poor electrical contact or physical damage to the module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the kit include enough connectors for a full I\/O base?\u003c\/strong\u003e\u003cspan\u003eThe kit contains three connectors in one row.\u003c\/span\u003e\u003cspan\u003e Depending on the specific Modicon Momentum or Quantum module being used,\u003c\/span\u003e\u003cspan\u003e you may require multiple kits to populate the entire I\/O interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Preparation:\u003c\/strong\u003e\u003cspan\u003e For optimal conductivity and ease of insertion,\u003c\/span\u003e\u003cspan\u003e it is highly recommended to use wire-end ferrules on all stranded conductors.\u003c\/span\u003e\u003cspan\u003e This prevents fraying and ensures the spring clamp engages the full cross-section of the wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsertion Technique:\u003c\/strong\u003e\u003cspan\u003e Use a small flat-head screwdriver or a dedicated terminal tool to depress the spring actuator.\u003c\/span\u003e\u003cspan\u003e Insert the wire into the open cavity and release the tool to lock the conductor in place.\u003c\/span\u003e\u003cspan\u003e Tug gently on the wire to verify a secure mechanical bond.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Management:\u003c\/strong\u003e\u003cspan\u003e In environments with extreme mechanical oscillation (e.\u003c\/span\u003e\u003cspan\u003eg.,\u003c\/span\u003e\u003cspan\u003e near large motors or compressors),\u003c\/span\u003e\u003cspan\u003e ensure that field cables are appropriately strain-relieved before they reach the terminal block.\u003c\/span\u003e\u003cspan\u003e This prevents external mechanical stress from pulling against the spring mechanism.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLabeling Protocol:\u003c\/strong\u003e\u003cspan\u003e Utilize the space above the connectors for clear channel identification.\u003c\/span\u003e\u003cspan\u003e Because spring terminals allow for very high wiring density,\u003c\/span\u003e\u003cspan\u003e accurate labeling is critical for reducing troubleshooting time during maintenance cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574628203,"sku":"170XTS00200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/170xts00200-k4e3fo0yps5.png?v=1776159749"}],"url":"https:\/\/www.plcprotech.com\/pt\/collections\/schneider-electric.oembed?page=5","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}