{"product_id":"149986-01-149992-01-bently-nevada-3500-33-spare-16-channel-relay-control-module","title":"149986-01 + 149992-01 Módulo de Controle de Relé de 16 Canais Sobressalente 3500\/33 Bently Nevada","description":"\n\u003ch3\u003eVisão Geral\u003c\/h3\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecombinação 149986-01 + 149992-01 (149986-01\/149992-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econstitui o conjunto completo do Módulo de Relé de 16 Canais para o Sistema de Proteção de Máquinas Bently Nevada Série 3500. Esta solução de altura completa consiste no Módulo de Controle Principal \u003cstrong\u003e149986-01\u003c\/strong\u003e e no Módulo de Terminação de Saída \u003cstrong\u003e149992-01\u003c\/strong\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-58 citation-end-58\"\u003eProjetado para fornecer capacidades de alarme de alta densidade, este sistema permite 16 saídas de relé independentes que podem ser programadas com lógica complexa de \"votação\" via o Software de Configuração do Rack 3500.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-57 citation-end-57\"\u003eUtilizando portas lógicas AND\/OR, os engenheiros da planta podem acionar ações de proteção baseadas nos status Alerta, Perigo ou Não OK de qualquer canal de monitoramento dentro do rack.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEste sistema modular de relés é um componente crítico para desligamento automático de máquinas, protegendo ativos multimilionários em usinas, refinarias e plataformas offshore contra falhas mecânicas catastróficas.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO sistema é projetado para máxima flexibilidade e confiabilidade no controle industrial:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-56\"\u003e\u003c\/span\u003e\u003cstrong\u003eIntegração Lógica:\u003c\/strong\u003e\u003cspan class=\"citation-56 citation-end-56\"\u003e\u003cspan\u003e \u003c\/span\u003eCada um dos 16 canais possui Lógica de Acionamento de Alarme independente, capaz de processar variáveis medidas individuais ou combinações de canais de monitoramento.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-55\"\u003e\u003c\/span\u003e\u003cstrong\u003eModos Operacionais:\u003c\/strong\u003e\u003cspan class=\"citation-55 citation-end-55\"\u003e\u003cspan\u003e \u003c\/span\u003eOs relés são organizados em quatro grupos de quatro canais.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCada grupo pode ser selecionado por chave para operação \"Failsafe\" Normalmente Desenergizado (ND) ou Normalmente Energizado (NE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-54\"\u003e\u003c\/span\u003e\u003cstrong\u003eConstrução Padrão do Contato:\u003c\/strong\u003e\u003cspan class=\"citation-54 citation-end-54\"\u003e\u003cspan\u003e \u003c\/span\u003ePossui relés SPDT selados com epóxi e supressores de arco integrados de 250 Vrms para garantir a integridade dos contatos a longo prazo.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-53\"\u003e\u003c\/span\u003e\u003cstrong\u003eDiagnóstico Visual:\u003c\/strong\u003e\u003cspan class=\"citation-53 citation-end-53\"\u003e\u003cspan\u003e \u003c\/span\u003eO painel frontal inclui LEDs de alta visibilidade para status \"OK\" do módulo, piscadas de comunicação TX\/RX e indicadores individuais de Alarme de Canal para solução de problemas em tempo real.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNúmero do Modelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e149986-01 (Controle) + 149992-01 (Saída)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSistema de Proteção de Máquinas 3500\/33\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Relé\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelé SPDT (Single-Pole Double-Throw) de 16 Canais\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,8 watts típico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente Máxima Comutada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A (Carga Resistiva)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão Máxima Comutada (CA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vca\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão Máxima Comutada (CC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 Vcc (Padrão) \/ 30 Vcc (Failsafe\/Área Perigosa)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVedação Ambiental\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelés Selados com Epóxi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensões de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241 mm x 24,4 mm x 242 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso do Módulo Principal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,7 kg (1,6 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePosso instalar o módulo de relé de 16 canais em qualquer slot do rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epode ser colocado em qualquer um dos slots do rack 3500, desde que estejam à direita do Módulo de Interface de Dados Transitórios (TDI).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuais são os requisitos de software para este hardware específico?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePara utilizar o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e, seu sistema deve executar o software de Configuração de Rack 3500 versão 3.3 ou superior, e o software de Aquisição de Dados versão 2.40 ou superior.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePor que a classificação de tensão é menor para sistemas SIL ou em Áreas Perigosas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEm sistemas Failsafe ou de Aprovação Múltipla (-02), a tensão máxima comutada é reduzida para 30 Vcc\/Vrms para cumprir os requisitos de espaçamento da ATEX e da Zona 2 da América do Norte, além dos testes de segurança tipo 61010-1.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento da Carga dos Contatos\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-52\"\u003ePara contatos padrão de prata usados no\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e\u003cspan class=\"citation-52 citation-end-52\"\u003e, a carga mínima comutada é 100 mA @ 5 Vcc.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSe seu circuito de controle operar com correntes mais baixas (por exemplo, interfaceando com entradas digitais de alta impedância), certifique-se de usar a variante de Baixa Corrente (banhada a ouro) para evitar oxidação dos contatos e sinalização intermitente. Para contatos banhados a ouro, não exceda 5 mA para evitar danos ao banho.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupressão de Arco e Cargas Indutivas\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmbora o módulo inclua supressores de arco padrão de 250 Vrms, recomendamos fortemente a instalação de diodos flyback externos (para CC) ou varistores (para CA) ao acionar válvulas solenóides de alta indutância. Isso reduz EMI e prolonga a vida útil dos contatos do relé além dos 10.000 ciclos nominalmente previstos.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibilidade do Sistema e Segurança\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSe este módulo estiver integrado em um circuito de Segurança Funcional (SIL), você deve seguir rigorosamente os limites de tensão restritos especificados no certificado de segurança. Exceder 30 Vcc em uma aplicação em área perigosa viola a certificação do equipamento e pode criar risco de faísca. Sempre verifique as posições dos interruptores \"Normalmente Energizado\" vs \"Normalmente Desenergizado\" antes de energizar o rack para evitar desligamentos acidentais da máquina durante a comissionamento.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324151659,"sku":"149986-01ÿ+149992-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149986-01_149992-01-35nvljlewoh.jpg?v=1765519475","url":"https:\/\/www.plcprotech.com\/pt\/products\/149986-01-149992-01-bently-nevada-3500-33-spare-16-channel-relay-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}