{"product_id":"3500-91-01-01-01-161204-01-61216-01-egd-communication-gateway-module","title":"3500\/91-01-01-01 161204-01+61216-01 Módulo Gateway de Comunicação EGD","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003eBently Nevada 3500\/91-01-01-01 161204-01+161216-01\u003c\/strong\u003e é um módulo gateway de comunicação Ethernet Global Data (EGD) que oferece recursos abrangentes de comunicação para valores e status monitorados pelo rack 3500. Ele oferece um caminho de rede Ethernet com tempos de resposta adequados para aplicações de controle e integra-se perfeitamente a controladores compatíveis com o protocolo EGD. O conjunto é composto pelo módulo principal do gateway EGD do 3500\/91 (161204-01) e pelo módulo de E\/S Ethernet 10BASE-T\/100BASE-TX (161216-01).\u003c\/p\u003e\n\u003ch3\u003eRecursos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransmite status do rack, módulo, canal e valores de dados, além de valores de dados de ponto flutuante e setpoints.\u003c\/li\u003e\n\u003cli\u003eOferece suporte a funções de controle de grupo, incluindo Redefinição de grupo, Multiplicação de disparo de grupo, Inibição de alarme de grupo e Inibição de alarme especial de grupo.\u003c\/li\u003e\n\u003cli\u003eEquipado com LEDs de status no painel frontal, incluindo LED OK e LED TX\/RX.\u003c\/li\u003e\n\u003cli\u003eIntegra-se por meio de conector RJ-45 para conectividade Ethernet 10BASE-T\/100BASE-TX com par trançado.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegração de dados de monitoramento do rack 3500 a controladores compatíveis com o protocolo EGD.\u003c\/li\u003e\n\u003cli\u003eSistemas de monitoramento da condição de máquinas e controle de plantas em tempo real.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformações para pedido\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOpção \/ Peça\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrição\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/91-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eGateway de comunicação EGD do 3500\/91\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Tipo de módulo principal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e Módulo gateway de comunicação EGD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Tipo de módulo de E\/S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e Módulo de E\/S Ethernet 10BASE-T\/100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Opção de aprovação de agência\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e CSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e161204-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMódulo gateway EGD do 3500\/91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e161216-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMódulo de E\/S Ethernet 10BASE-T\/100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e161232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGuia do usuário do 3500\/91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEspecificações técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ Baker Hughes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocolos\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEGD (versão 2.01), Ethernet UDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePadrão Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 CSMA\/CD; 10BASE-T e 100BASE-TX (IEEE 802.3 e IEEE 802.3u)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo de energia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,4 watts, típico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura de operação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 °C a +65 °C (-22 °F a +150 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura de armazenamento\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C (-40 °F a +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, sem condensação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões do módulo principal (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm (9,50 pol x 0,96 pol x 9,52 pol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso do Módulo Principal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.79 kg (1.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões do Módulo de E\/S (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso do Módulo de E\/S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 kg (0.85 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEspaço do Rack para o Módulo Principal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot frontal de altura total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEspaço do Rack para o Módulo de E\/S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot traseiro de altura total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequisitos de Software e Hardware:\u003c\/strong\u003e Requer a versão 3.70 ou superior do software de configuração do rack 3500 e um módulo TDI 3500\/22M para se comunicar com os módulos do monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequisitos de Firmware:\u003c\/strong\u003e Requer a versão 1.20 ou superior do firmware TDI (3500\/22M). Para obter suporte à troca consumida, é necessária a versão 2.21 ou superior do firmware de 4 canais.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimitação do Rack:\u003c\/strong\u003e É permitido apenas 1 módulo EGD por rack 3500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontagem em Slot:\u003c\/strong\u003e Instale o módulo principal em 1 slot frontal de altura total e o módulo de E\/S correspondente no slot traseiro de altura total correspondente.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformidade e certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Está em conformidade com a parte 15 das regras da FCC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e Diretiva 2014\/30\/UE da Comunidade Europeia; Normas: EN 61000-6-2, EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegurança Elétrica:\u003c\/strong\u003e Diretiva 2014\/35\/UE da Comunidade Europeia; Norma: EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Diretiva 2011\/65\/UE da Comunidade Europeia.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarítimo:\u003c\/strong\u003e Regras da DNV GL para classificação; Regras da ABS para Condições de Classificação (Regras para Embarcações de Aço, Unidades e Estruturas Offshore).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eÁrea Perigosa cNRTLus:\u003c\/strong\u003e Classe I, Zona 2: AEx\/Ex nA nC ic IIC T4 Gc; Classe I, Zona 2: AEx\/Ex ec nC ic IIC T4 Gc; Classe I, Divisão 2, Grupos A, B, C e D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF) quando instalado conforme o desenho 149243 ou 149244.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF) quando instalado conforme o desenho 149243 ou 149244.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53650359910763,"sku":"3500\/91-01-01-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-91-01-01-01_161204-01_61216-01_3.jpg?v=1785670836","url":"https:\/\/www.plcprotech.com\/pt\/products\/3500-91-01-01-01-161204-01-61216-01-egd-communication-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}