{"product_id":"abb-3bhe039426r0101-uf-c912-a101-eoi-protection-board","title":"ABB 3BHE039426R0101 Placa de Proteção EOI UF C912 A101","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eA \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BHE039426R0101 (UF C912 A101)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma placa de proteção especializada e módulo de interface de Fim de Instrução (EOI) projetado para Drives de Média Tensão (MV) da ABB, especificamente nas linhas de produtos ACS 2000 e ACS 6000. Em aplicações industriais pesadas, como propulsão marítima, moagem mineral e bombeamento de água em grande escala, transientes elétricos e erros de sincronização podem causar falhas catastróficas no hardware. A \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUF C912 A101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunciona como um mecanismo de defesa de primeira linha, monitorando parâmetros críticos do drive para executar sequências de proteção em alta velocidade. Ao garantir a integridade dos sinais de controle e fornecer isolamento rápido, esta placa é fundamental para maximizar o MTBF (Tempo Médio Entre Falhas) e evitar paradas não programadas dispendiosas em ambientes de conversão de alta potência.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eA arquitetura UF C912 A101 é otimizada para proteção em tempo real e feedback dentro do subrack de controle do drive. Ela gerencia lógica de alta velocidade para detecção de falhas e assegura que os disparos de proteção sejam comunicados aos drivers de gate dos semicondutores de potência com latência mínima.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegração ao Sistema:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizada principalmente nas configurações ACS 2000 e ACS 6000 AD (Drive Assíncrono).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntercambialidade:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara sistemas ACS 2000, o 3BHE039426R0111 (UF C912 A111) é um substituto funcional 1-para-1. Note que a versão R0111 não suporta funções de encoder SSI, mas esse recurso normalmente não é utilizado na série ACS 2000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerificação de Aplicação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara aplicações ACS 6000 SD (Drive Síncrono), é necessária verificação de engenharia para garantir compatibilidade de firmware e hardware antes da implantação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAtributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BHE039426R0101\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDesignação ABB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUF C912 A101: EOI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlaca de Proteção \/ EOI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePaís de Origem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuíça \/ Estados Unidos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso Líquido do Produto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNúmero da Tarifa Aduaneira\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85049090\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Produto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePeças_de_Reposição\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUNSPSC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e39122004\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePosso usar o UF C912 A111 no lugar do A101 em um drive ACS 2000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim, o UF C912 A111 (3BHE039426R0111) é um substituto direto 1-para-1 para o ACS 2000. Ele não possui a função de encoder SSI, mas como as unidades ACS 2000 não utilizam encoders SSI, não há perda de funcionalidade.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuais informações são necessárias antes de comprar esta placa de proteção?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO número de série específico do drive é obrigatório antes da compra. Isso garante que a revisão do hardware e o firmware carregado de fábrica na placa sejam compatíveis com a configuração do seu drive MV existente.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEsta placa é compatível com ACS 6000 SD (Drives Síncronos)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA compatibilidade para a variante Drive Síncrono (SD) deve ser verificada através dos canais oficiais de suporte técnico. Embora seja padrão para o Drive Assíncrono (AD), a variante SD pode ter requisitos diferentes de temporização ou interface.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSuporte de Engenharia e Segurança na Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerificação do Número de Série:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEm nenhuma circunstância esta placa deve ser instalada sem verificar o número de série do drive na base de dados global da ABB. Revisões incorretas de hardware podem levar a bypass de proteção ou sequências de disparo incorretas do drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManuseio Sensível a Descarga Eletrostática:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEste módulo contém componentes de lógica de gate altamente sensíveis. Use uma pulseira antiestática (ESD) aterrada durante todo o processo de instalação. Não toque diretamente nos conectores de borda dourados ou nos circuitos integrados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocolo de Segurança para Média Tensão:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAntes de acessar o interior do drive para substituir a 3BHE039426R0101, certifique-se de que o fornecimento de Média Tensão esteja bloqueado e etiquetado (LOTO). Aguarde pelo menos 15 a 30 minutos para que os capacitores do link DC descarreguem até um nível seguro (abaixo de 50 VDC), conforme o manual de segurança específico do seu drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSincronização de Firmware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApós a instalação do hardware, verifique se é necessária uma atualização de firmware ou sincronização de parâmetros via DriveWindow ou ferramenta de serviço ABB relevante para garantir que a nova placa seja reconhecida pelo controlador principal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668531114347,"sku":"3BHE039426R0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-3bhe039426r0101-ufc912-a101-eoi-y45gsmjabjk_01e5afbe-dcf7-40f8-8f71-955222808e2f.jpg?v=1765532914","url":"https:\/\/www.plcprotech.com\/pt\/products\/abb-3bhe039426r0101-uf-c912-a101-eoi-protection-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}