{"product_id":"abb-immfc03-bailey-infi-90-multifunction-controller","title":"Controlador Multifuncional ABB IMMFC03 Bailey Infi 90","description":"\u003ch3\u003eDescrição\u003c\/h3\u003e\n\u003cp\u003eO \u003cstrong\u003eABB IMMFC03\u003c\/strong\u003e é um poderoso Módulo Controlador Multifuncional dentro da família de controladores \u003cstrong\u003eBailey Infi 90\u003c\/strong\u003e. Este módulo executa estratégias de controle analógicas, digitais, por lotes e avançadas projetadas pelo usuário, gerenciando até 64 módulos escravos de E\/S (incluindo a mistura de escravos de alta e baixa potência com um máximo de 20 escravos de alta potência). É capaz de rodar 4.000 linhas de programas em \u003cstrong\u003eBASIC\u003c\/strong\u003e ou 5.000 linhas em \u003cstrong\u003eC\u003c\/strong\u003e, permitindo que blocos de função e programas em linguagem rodem simultaneamente. O \u003cstrong\u003eABB IMMFC03\u003c\/strong\u003e serve como substituto funcional direto do Network 90 NMFC03.\u003c\/p\u003e\n\u003cp\u003eA arquitetura de hardware consiste em duas placas de circuito impresso conectadas por um cabo flat — a placa da Unidade Central de Processamento (\u003cstrong\u003eCPU\u003c\/strong\u003e) e a placa de Memória (\u003cstrong\u003eMEM\u003c\/strong\u003e) — que se fixam a uma única placa frontal. Projetado para residir na \u003cstrong\u003eUnidade de Montagem de Módulo INFI 90 (MMU)\u003c\/strong\u003e, ocupa dois slots e se comunica pelo barramento do módulo e pelo barramento expansor escravo.\u003c\/p\u003e\n\u003ch3\u003eCaracterísticas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuporte a Configuração Redundante:\u003c\/strong\u003e Oferece redundância em espera quente quando emparelhado com um módulo de backup configurado de forma idêntica e executando o mesmo nível de revisão do firmware, alcançando transferência de controle sem interrupções durante a falha.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacidades de Configuração On-Line:\u003c\/strong\u003e Permite que os usuários façam modificações de configuração (incluindo alterações em programas BASIC e C) no controlador de backup sem afetar o módulo principal ou interromper a lógica de controle de processo ativa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbiente de Programação Diversificado:\u003c\/strong\u003e Executa simultaneamente estratégias de controle personalizadas via códigos de função padrão Bailey, programas em BASIC e em linguagem C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstrutura Abrangente de Segurança:\u003c\/strong\u003e Possui detecção e correção de erros de hardware (EDAC) para RAM dinâmica, decodificação de endereços ilegais, um Temporizador de Falhas de Máquina (MFT) independente e gerenciamento de memória aplicado por hardware para bloquear programas em C em seções definidas da RAM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarcação Avançada de Qualidade de Processo:\u003c\/strong\u003e Monitora sinais locais e remotos de E\/S para estados fora do intervalo ou falhas, marcando automaticamente pontos de dados comprometidos como \"qualidade ruim\" para preservar a previsibilidade do processo.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAplicações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControle de loop de processo regulatório analógico, digital e avançado\u003c\/li\u003e\n\u003cli\u003eControle de processo em lote e sequenciamento industrial\u003c\/li\u003e\n\u003cli\u003eManipulação de dados em alto nível usando programação em C e BASIC\u003c\/li\u003e\n\u003cli\u003eConfigurações redundantes de automação de processo DCS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 64.7679%;\"\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eFabricante\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eABB \/ Elsag Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eMicroprocessador\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e68020 (operando a 8 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eRAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e512 Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eRAM com bateria (não volátil)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e80 Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eUVROM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e256 Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003ePortas de Comunicação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e\n\u003cp\u003e(2) RS-232-C Serial\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e(2) RS-422 Link SAC\/DCS (redundância MFC para MFC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eTaxas de Baud da Porta Serial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eAté 19,2 kilobaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eLink do Barramento do Módulo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eLink ponto a ponto de 83,3 kilobaud (suporta até 32 drops)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eBarramento Expansor de Escravos\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eBarramento paralelo de 8 bits, largura de banda de 500 Kbytes\/segundo (suporta 64 escravos)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eLink da Estação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eCanal serial de 5 kilobaud para até 8 estações de painel (IISAC01 ou NDCS03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e\n\u003cp\u003e4,5 Amperes nominal a +5 VDC (23 Watts)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e37 mA nominal a +15 VDC (0,6 Watts)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e18 mA nominal a -15 VDC (0,3 Watts)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eDissipação de Energia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e37,68 Watts máximo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eMontagem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eOcupa dois slots na Unidade de Montagem de Módulo padrão Infi 90 (MMU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eTemperatura Ambiente\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e0 °C a 70 °C (32 °F a 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eUmidade Relativa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003e\n\u003cp\u003e5% a 95% até 55 °C (131 °F) (sem condensação)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e5% a 45% a 70 °C (158 °F) (sem condensação)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003ePressão Atmosférica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eNível do mar até 3 km (1,86 milhas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eQualidade do Ar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eNão corrosivo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8101%;\"\u003e\u003cstrong\u003eCertificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.7679%;\"\u003eCertificado CSA para uso como equipamento de controle de processo em local comum (não perigoso)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConexões\/Interfaces\u003c\/h3\u003e\n\u003ch4\u003ePinos do Conector de Borda P1\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePino do Conector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e+ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e- 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eN\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eN\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eComum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eComum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e+ 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e- 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eInterrupção de Falha de Energia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eInterrupção de Falha de Energia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eBarramento do Módulo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eBarramento do Módulo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePinos do Conector de Borda P2\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePino do Conector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D1 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eBit de Dados DO (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D3 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D2 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D5 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D4 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D7 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eBit de Dados D6 (ativo em nível baixo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eRelógio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eSincronização\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eN\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eN\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePinos do Conector de Borda P3\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePino do Conector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunção\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ A\u003c\/td\u003e\n\u003ctd\u003eLink SAC\/DCS (+) \/ Link SAC\/DCS (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 \/ B\u003c\/td\u003e\n\u003ctd\u003eDados de Transmissão do Link de Redundância (+) \/ Dados de Transmissão do Link de Redundância (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 \/ C\u003c\/td\u003e\n\u003ctd\u003eRecepção de Dados do Link de Redundância (-) \/ Recepção de Dados do Link de Redundância (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 \/ D\u003c\/td\u003e\n\u003ctd\u003eTransmissão de Dados da Porta Terminal \/ Recepção de Dados da Porta Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 \/ E\u003c\/td\u003e\n\u003ctd\u003eSolicitação de Envio da Porta Terminal \/ Liberação para Envio da Porta Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6 \/ F\u003c\/td\u003e\n\u003ctd\u003eDetecção de Portadora de Dados \/ N\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7 \/ G\u003c\/td\u003e\n\u003ctd\u003eTransmissão de Dados da Porta da Impressora \/ Recepção de Dados da Porta da Impressora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 \/ H\u003c\/td\u003e\n\u003ctd\u003eSolicitação de Envio da Porta da Impressora \/ Liberação para Envio da Porta da Impressora\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 \/ I\u003c\/td\u003e\n\u003ctd\u003eDetecção de Portadora de Dados \/ N\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 \/ J\u003c\/td\u003e\n\u003ctd\u003eSaída Digital 1 (+) \/ Saída Digital 1 (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11 \/ K\u003c\/td\u003e\n\u003ctd\u003eSaída Digital 2 (+) \/ Saída Digital 2 (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 \/ L\u003c\/td\u003e\n\u003ctd\u003eN\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13 \/ M\u003c\/td\u003e\n\u003ctd\u003eN\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14 \/ N\u003c\/td\u003e\n\u003ctd\u003eN\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 \/ O\u003c\/td\u003e\n\u003ctd\u003eN\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProteção Contra Estática:\u003c\/strong\u003e Sempre use uma pulseira de aterramento e uma superfície de trabalho dissipativa de estática ao manusear o módulo para evitar danos por descarga eletrostática (ESD).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguração de Endereço de Hardware e Opções:\u003c\/strong\u003e Configure os dipswitches U72 (Opções), U73 (Taxa de Baud) e U75 (Endereço do Módulo) na placa CPU antes de inserir o módulo no rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMitigação de Risco de Choque Elétrico:\u003c\/strong\u003e Desconecte toda a energia antes de instalar dipshunts para módulos escravos no backplane da MMU (barramento expansor escravo) para evitar choque grave ou fatal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoteamento do Cabo de Interface:\u003c\/strong\u003e Conecte o cabo de interface da Unidade de Terminação NTMF01 ou do Módulo de Terminação NIMF01 diretamente ao \u003cstrong\u003econector de borda P3\u003c\/strong\u003e da placa CPU. Não conecte isso à placa MEM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInserção Física:\u003c\/strong\u003e Deslize o conjunto de duas placas suavemente na posição designada do slot da MMU até que os conectores da borda traseira estejam firmemente encaixados no backplane. Fixe girando os dois parafusos presos da faceplate meia volta até que as ranhuras dos parafusos fiquem orientadas verticalmente.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManutenção e Remoção de Poeira:\u003c\/strong\u003e Limpe e aperte todas as conexões de energia e aterramento a cada 6 meses ou durante paradas programadas da planta. Use um aspirador antiestático para remover o acúmulo de poeira dos módulos, da MMU, do conjunto do ventilador e do painel de entrada de energia.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformidade e Certificações\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certificado para uso como equipamento de controle de processo em locais comuns (não perigosos).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668627878251,"sku":"IMMFC03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-immfc03-multi-function-controller-dkq5g04nyx3_a357e7e8-ff13-4fdc-b98a-1c04d881ea24.jpg?v=1765536054","url":"https:\/\/www.plcprotech.com\/pt\/products\/abb-immfc03-bailey-infi-90-multifunction-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}