{"product_id":"abb-nmbp-01-modbus-plus-adapter-module","title":"ABB NMBP-01 Modbus Plus Adapter Module","description":"\u003cp\u003eThe \u003cstrong\u003eNMBP-01\u003c\/strong\u003e is a fieldbus network connection interface designed to bridge variable speed drives directly into automated networks. This \u003cstrong\u003eModbus Plus Adapter Module\u003c\/strong\u003e acts exactly like a network node, establishing transparent communication for configuration, parameter modification, and high-speed feedback loop handling. The module features integrated dual-channel plastic fiber optic ports utilizing the Distributed Drives Communication System (DDCS) protocol to deliver localized electrical isolation between the logic circuit and power electronics. Engineered for critical environments, it enables control location command mapping, speed reference feeding, and direct parameter reads and writes via simulated holding register allocations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeamless network device integration enabling full drive control mapping including start, stop, direction, and reference injection.\u003c\/li\u003e\n\u003cli\u003eDual physical layer interfaces featuring a standard 9-pin D-shell Modbus Plus fieldbus network connector and dedicated DDCS optical receivers and transmitters.\u003c\/li\u003e\n\u003cli\u003eGlobal Data broadcasting capability supporting synchronous transfer up to 3 words of real-time control loop and feedback parameters.\u003c\/li\u003e\n\u003cli\u003eBuilt-in local hardware diagnostics via specialized flashing Status LEDs and an integrated Modbus Plus network health indicator.\u003c\/li\u003e\n\u003cli\u003eHigh-speed data update modes including an alternative fast architecture that bypasses standard logic counters to optimize processing times.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable speed motor drive coordination within large-scale Modicon Modbus Plus automation networks.\u003c\/li\u003e\n\u003cli\u003eMulti-drive industrial configurations connecting up to 8 drives on a single token-passing segment.\u003c\/li\u003e\n\u003cli\u003eMulti-level cross-network plant automation topologies spanning remote bridges and multiplexers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNMBP-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus Plus Adapter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MBit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDDCS Link Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDDCS Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlastic core fiber optic cable, 1 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDDCS Maximum Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m between stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Network Nodes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 stations including bridges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulated 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, no condensation allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV 5\/50 ns (IEC 801-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX2:1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX2:2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX2:3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX2:4-9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX1:1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24 V Regulated VDC Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX1:2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGnd Shield Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX1:3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Power Supply Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eV3 (Blue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDCS Optical Link Receiver Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eV4 (Grey)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDCS Optical Link Transmitter Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Snap the device directly onto a standard DIN mounting rail inside or outside the cabinet space. Ensure a minimum free clearance of 10 mm from adjacent components or enclosure structural walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Isolate all primary drive electrical connections before handling the unit. Allow a minimum period of 5 minutes for internal capacitor banks to fully discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Handling:\u003c\/strong\u003e Maintain a strict minimum short-term fiber cable bend radius of 25 mm. Never exceed the long-term structural tensile load rating of 1 N.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Earthing:\u003c\/strong\u003e Ensure the entire Modbus Plus fieldbus network cable shield remains entirely isolated from external ground sources at every point. Connect the local segment shield line exclusively to terminal X1:2.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668624404843,"sku":"NMBP-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-nmbp-01-modbus-plus-adapter-hdi24eqyqam_f913880c-f89b-47b1-b19c-2e73a253c9cf.jpg?v=1765535924","url":"https:\/\/www.plcprotech.com\/pt\/products\/abb-nmbp-01-modbus-plus-adapter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}