{"product_id":"abb-pu515a-3bse032401r1-system-800xa-communication-module","title":"ABB PU515A 3BSE032401R1 System 800xA Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003ePU515A\u003c\/strong\u003e (Product ID: \u003cstrong\u003e3BSE032401R1\u003c\/strong\u003e) is a hardware-integrated \u003cstrong\u003eReal-Time Accelerator (RTA) board\u003c\/strong\u003e designed to facilitate high-speed industrial network communication within the \u003cstrong\u003eSystem 800xA\u003c\/strong\u003e control environment. This professional PCI interface card functions as a dedicated processing interface that links standard PC-based control architectures with Master and MOD eDCN automation systems. Featuring an onboard CS503V1 dual-channel MB300 communication subsystem and an independent 25 MHz processor, the \u003cstrong\u003ePU515A 3BSE032401R1\u003c\/strong\u003e unloads deterministic time-critical communication tasks from the host operating system. It handles data translation, dual-channel protocol execution, and physical bus routing over standard 15-pin connection interfaces to prevent process control disruptions in complex Advant OCS network configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in CS503V1 dual-channel MB300 communication module delivering high-throughput data transfer rates up to 10,000 kbit\/s.\u003c\/li\u003e\n\u003cli\u003eIndependent onboard 25 MHz processing core dedicated strictly to handling real-time network traffic acceleration.\u003c\/li\u003e\n\u003cli\u003eEquipped with 16 megabytes (MB) of local integrated RAM to optimize sequence buffers and network queues.\u003c\/li\u003e\n\u003cli\u003eDual 15-pin female D-sub connectors providing independent interfaces for redundant network physical media routing.\u003c\/li\u003e\n\u003cli\u003eHighly versatile physical bus interface supporting standard 32-bit or 64-bit PCI slots as well as legacy PCI-X slots.\u003c\/li\u003e\n\u003cli\u003eSolid-state component selection utilizing zero internal batteries to reduce long-term preventative maintenance demands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time network interfaces connecting System 800xA server platforms to legacy Advant Master controllers.\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial data acquisition and supervisory tracking loops via MB300 networks.\u003c\/li\u003e\n\u003cli\u003eCommunication subsystem acceleration for server connectivity in MOD eDCN distribution environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCatalog Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eExchange Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePU515A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3BSE032401R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePU515A Real-Time Accelerator, RTA, board.\u003c\/td\u003e\n\u003ctd\u003eEXC3BSE032401R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePU515A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE032401R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMB300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Processors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPU Clock Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V or 5V 32-bit 33MHz PCI, 64-bit PCI, or 100\/133MHz PCI-X slot (runs at 33MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden (SE) \/ Poland (PL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin female D-sub connector\u003c\/td\u003e\n\u003ctd\u003eMain MB300 bus connection channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin female D-sub connector\u003c\/td\u003e\n\u003ctd\u003eRedundant or secondary MB300 bus connection channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD) Protection:\u003c\/strong\u003e Handle the PCB assembly strictly at its physical edges and metal mounting brackets while using an approved ESD ground strap to avoid component damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Interface Selection:\u003c\/strong\u003e Insert the card directly into a matching 3.3V or 5V 32-bit\/64-bit standard PCI slot, or a compatible 100\/133MHz PCI-X slot. Note that the card interfaces at a 33MHz bus speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Fasten the integrated faceplate retaining screw firmly onto the server or industrial PC chassis rail to secure appropriate ground pathing and prevent physical card shifting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief:\u003c\/strong\u003e Secure the connected 15-pin female D-sub network cables to prevent unneeded physical torque from altering the connection seating at the backplane interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514959723,"sku":"PU515A 3BSE032401R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pu515a-3bse032401r1-real-time-accelerator-board-p0xz0slwd1p_cdc35145-404f-4c4a-8051-2f1183399373.jpg?v=1765532647","url":"https:\/\/www.plcprotech.com\/pt\/products\/abb-pu515a-3bse032401r1-system-800xa-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}