{"product_id":"allen-bradley-1756-hsc-b-controllogix-high-speed-counter-module","title":"Allen-Bradley 1756-HSC\/B ControlLogix Módulo de Contador de Alta Velocidade","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\/B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um módulo de Contador de Alta Velocidade (HSC) de alto desempenho projetado para a plataforma Allen-Bradley ControlLogix. Este módulo é desenvolvido para aplicações de movimento e contagem de precisão que excedem as capacidades de varredura dos módulos de entrada digital padrão. É capaz de processar fluxos rápidos de pulsos de codificadores, medidores de fluxo e sensores de proximidade com extrema precisão.\u003c\/p\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSérie B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeste módulo oferece estabilidade refinada e é um componente essencial para aplicações que exigem detecção de eventos em alta velocidade, como linhas de engarrafamento, manuseio de materiais e monitoramento de velocidade de turbinas. Ao descarregar a lógica de contagem da CPU para o hardware do módulo, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarante que os pulsos nunca sejam \"perdidos\" devido a flutuações no tempo de varredura do CLP.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eO 1756-HSC oferece capacidades robustas de E\/S adaptadas para contagem industrial:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArquitetura de Contador Duplo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePossui dois contadores independentes, permitindo o monitoramento simultâneo de dois processos de alta velocidade diferentes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrês Entradas por Contador:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCada contador aceita três entradas (normalmente sinais A, B e Z\/Índice), facilitando o suporte completo a codificadores quadratura para detecção de direção e posição.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSinais de Saída Quádruplos:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInclui quatro saídas físicas que podem ser configuradas para disparar com base em valores específicos de contagem (Valor Pré-definido\/Atual), permitindo respostas em tempo real no nível de hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResposta em Alta Velocidade:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProjetado para lidar com frequências de até\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(em certas configurações), fornecendo a resolução necessária para fabricação em alta velocidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEficiência Energética:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConsome apenas 300 mA do backplane de 5,1V e um consumo desprezível de 3 mA da fonte de 24V, resultando em uma baixa pegada total de energia do backplane de 1,6 Watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRecurso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-HSC (Série B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinha de Produto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCanais do Contador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEntradas por Contador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 (A, B e Z)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSaídas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente do Backplane\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mA a 5,1V CC \/ 3 mA a 24V CC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDissipação Máxima de Potência\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,6 Watts a 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDissipação Térmica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19,1 BTU\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 60 °C (32 a 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLargura do Slot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,23 kg (0,50 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003ePerguntas Frequentes Técnicas\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a diferença entre a Série A e a Série B?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEmbora ambas as séries compartilhem as mesmas especificações funcionais básicas, a Série B normalmente inclui revisões de hardware para maior durabilidade dos componentes e melhor resistência a interferência eletromagnética (EMI). Para a maioria das aplicações, a Série B é preferida por sua compatibilidade com firmware atualizado e proteção aprimorada do circuito.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEste módulo suporta um encoder incremental padrão?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. A configuração de três entradas por contador é projetada especificamente para encoders incrementais. Suporta decodificação quadratura X1, X2 e X4, além dos modos Contagem Crescente\/Decrescente e Pulso\/Direção.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO módulo requer uma fonte de alimentação externa para as entradas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim. As entradas e saídas do 1756-HSC requerem uma fonte de alimentação externa de campo (tipicamente 12\/24V DC). A corrente do backplane listada é estritamente para a lógica interna do módulo e comunicação com a CPU ControlLogix.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFiação e Integridade do Sinal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA contagem em alta velocidade é altamente sensível a ruídos elétricos. Para evitar \"contagens fantasmas\":\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBlindagem:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse cabos de par trançado blindado de alta qualidade para todas as conexões do encoder. Conecte a blindagem a um único ponto de aterramento no chassi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRoteamento de Cabos:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNunca passe cabos de encoder no mesmo conduíte ou bandeja que fios de motor CA de alta tensão ou cabos de saída de VFD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBloco de Terminais:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertifique-se de que o bloco de terminais removível 1756-TBCH ou 1756-TBSH (36 pinos) esteja firmemente encaixado.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguração do Módulo no Studio 5000\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAo adicionar o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eà sua árvore de E\/S:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeleção de Filtro:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigure os filtros de entrada para corresponder à frequência de pulso esperada. Definir um filtro muito baixo \"suaviza\" pulsos legítimos de alta velocidade, enquanto definir muito alto pode permitir que ruídos sejam contados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModo do Contador:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelecione entre \"Contador\" (para totalização) ou \"Encoder\" (para posicionamento).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmazenamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse o recurso \"Armazenamento\" para capturar o valor atual da contagem em uma transição específica da entrada 'Z' para sequências precisas de homing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento Térmico\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO 1756-HSC dissipa até 5,6 Watts. Certifique-se de que o chassi ControlLogix esteja montado em um gabinete bem ventilado. Se a temperatura interna do gabinete se aproximar de 60 °C, considere utilizar resfriamento forçado para evitar a redução térmica da precisão da contagem.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190569323,"sku":"1756-HSC\/B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-hsc-b-hsc-module-ra4uewbbisd_8c782b85-0ecf-4a79-8a3b-67662f5047df.jpg?v=1766114611","url":"https:\/\/www.plcprotech.com\/pt\/products\/allen-bradley-1756-hsc-b-controllogix-high-speed-counter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}