{"product_id":"allen-bradley-1756-l63xt-controllogix-extreme-environment-processor-module","title":"Allen-Bradley 1756-L63XT Módulo Processador para Ambiente Extremo ControlLogix","description":"\u003ch3\u003eDescrição Funcional\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L63XT (1756-L63XT)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um controlador ControlLogix robusto projetado explicitamente para operação em atmosferas de temperatura extrema e alta vibração. Funcionando em ambientes de campo de processo contínuo severos, incluindo campos de extração de petróleo e gás, subestações de energia em desertos e grandes minas a céu aberto, esta unidade de processamento de alto desempenho oferece controle de automação sem compromissos onde hardware PLC padrão falha. Com 8 MB de memória de execução do usuário e 478 KB de armazenamento dedicado para memória de E\/S, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L63XT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaplica um revestimento conformal otimizado para isolar a eletrônica interna da umidade atmosférica e contaminantes químicos transportados pelo ar. A implantação deste controlador para ambientes extremos previne corrupção crítica de dados, resiste a ciclos térmicos severos sem degradação do relógio e fornece uma plataforma de redundância sem interrupções nas camadas ControlNet para minimizar paradas catastróficas da planta e otimizar o tempo de atividade do sistema remoto.\u003c\/p\u003e\n\u003ch3\u003eInfraestrutura de Hardware e Capacidade de Rede\u003c\/h3\u003e\n\u003cp\u003eA estrutura arquitetônica subjacente do processador 1756-L63XT enfatiza ampla integração de rede, execução lógica multitarefa e isolamento físico rigoroso.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerfil de Execução de Tarefas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuporta até 32 tarefas independentes do controlador, permitindo um máximo de 100 programas industriais por grupo de tarefas individual. Essa configuração lida com gatilhos complexos de eventos assíncronos juntamente com rotinas de loop críticas em tempo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmpla Integração de Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComunica-se perfeitamente em redes industriais por meio de adaptadores nativos montados em rack, incluindo EtherNet\/IP, ControlNet, DeviceNet, Remote I\/O, SynchLink e Data Highway Plus (DH+).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Serial Ponto a Ponto Integrada:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncorpora um caminho de comunicação serial RS-232 de 1 porta executando canais DF1 full\/half-duplex, parâmetros de modem de rádio DF1, fluxos de texto ASCII mestre e tradução de protocolo Modbus via lógica de controlador localizada.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArquitetura de sistema redundante:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegra motores de redundância cross-loading que suportam rastreamento sincronizado de parceiros por meio de um único link de rede ControlNet, garantindo transferência contínua do processador principal para o de backup sem perda dos dados das variáveis de estado do processo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMatriz de desempenho técnico\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro operacional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValores detalhados de engenharia\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-L63XT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClassificação do componente\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMódulo processador para ambiente extremo (XT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePaís de origem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEstados Unidos (US)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso líquido do hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,57 kg (1,25 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacidade de memória do usuário\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 megabytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemória dedicada de E\/S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e478 kilobytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacidade máxima total de E\/S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128.000 total (128.000 digital \/ 4.000 analógico)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolamento contínuo do circuito\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 V contínuos (testado a 720 V DC por 60 s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de corrente a 5,1 V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de corrente a 24 V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDissipação total de energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDissipação de energia térmica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11,9 BTU por hora\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura atmosférica de operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 a 70 °C (-13 a 158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de armazenamento fora de operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 a 85 °C (-40 a 185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFaixa de umidade relativa\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 a 95% (sem condensação)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibração mecânica operacional\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAceleração de 2 g de 10 a 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChoque máximo em operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eImpacto mecânico de pulso de 30 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChoque máximo fora de operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eImpacto mecânico de pulso de 50 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Aplicação e Engenharia de Campo\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePor que a classificação de temperatura ambiente diminui ao usar tipos específicos de chassi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO 1756-L63XT é classificado independentemente para até 70 °C de temperatura do ar ambiente. No entanto, quando montado dentro de um chassi de ambiente extremo 1756-A7LXT, a restrição térmica do sistema limita o conjunto a -25 a 60 °C. Por outro lado, quando integrado em um layout de distribuição de campo FLEX I\/O-XT emparelhado, a tolerância térmica inferior cai com segurança para -20 a 70 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuais cartões de memória não volátil específicos podem ser utilizados para backup não apagável?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO módulo é estritamente limitado a cartões CompactFlash industriais de grau comercial. Ele suporta o modelo de cartão de 64 megabytes 1784-CF64 ou o modelo de cartão de alta capacidade de 128 megabytes 1784-CF128. Cartões flash comerciais padrão não-Rockwell não devem ser utilizados.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo a unidade mantém a integridade dos dados durante uma perda completa de energia do backplane do chassi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO 1756-L63XT utiliza um módulo integrado de armazenamento de energia ou um pacote de bateria industrial de lítio substituível. Essa fonte de energia reserva fornece correntes contínuas de gotejamento para o bloco SRAM, preservando tabelas variáveis ativas, relógios internos e marcadores de status do sistema até que as tensões da linha do sistema se recuperem.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eComissionamento de Campo e Diretrizes Rígidas de Segurança\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFolgas Térmicas do Chassi e Fluxo de Ar:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAo instalar o 1756-L63XT em um invólucro NEMA selado para ambientes extremos, garanta espaçamento vertical adequado acima e abaixo do chassi 1756-A4LXT, 1756-A5XT ou 1756-A7XT. Mantenha pelo menos 50,8 mm (2,0 polegadas) de espaço livre de ar ao redor da carcaça externa para garantir o resfriamento passivo por convecção natural na face do processador durante picos operacionais em altas temperaturas ambiente.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocolos de Proteção contra Descarga Eletrostática:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOs chips de processamento a bordo e as redes eletrônicas de montagem superficial são altamente suscetíveis a arcos ESD súbitos. Os engenheiros de manutenção devem usar uma pulseira ESD aterrada, conectada diretamente à estrutura metálica do invólucro, antes de deslizar o controlador para fora do slot do chassi ou manipular o botão de parada\/redefinição frontal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBlindagem da Porta Serial e Supressão de Ruído:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTodos os links seriais RS-232 personalizados que utilizam o canal integrado devem implementar cabeamento blindado dedicado. Termine a malha de blindagem geral do cabo na carcaça metálica em forma de D na extremidade do controlador. Não roteie as linhas seriais próximas a cabos de acionamento de motor de alta corrente ou linhas de energia indutivas para evitar interferência de sinal em redes ASCII ou DF1.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMódulo de Assento Mecânico e Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlinhe as bordas superior e inferior da placa de circuito com as trilhas guia designadas no chassi de plástico. Pressione suavemente o módulo para trás até que os conectores traseiros se encaixem firmemente no barramento ativo do backplane. Aperte os parafusos de travamento superior e inferior com um torque de 0,6 Nm (5,3 in-lbs) para evitar perda de contato sob vibrações intensas no piso de até 2 g.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172481387,"sku":"1756-L63XT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l63xt-controllogix-xt-logix5563-processor-r3r2aiaarlk_fa2e9179-62e1-42cf-a1e9-cf3cb43a3222.jpg?v=1766114090","url":"https:\/\/www.plcprotech.com\/pt\/products\/allen-bradley-1756-l63xt-controllogix-extreme-environment-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}