{"product_id":"allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller","title":"Allen-Bradley 1762-L40BWA MicroLogix 1200 Controlador de 40 Pontos","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-931\"\u003eO\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1762-L40BWA (1762L40BWA)\u003c\/strong\u003e\u003cspan class=\"citation-931 citation-end-931\"\u003e\u003cspan\u003e \u003c\/span\u003eé um controlador lógico programável compacto e de alto desempenho da família MicroLogix 1200, projetado para lidar com aplicações industriais complexas com um pequeno espaço físico.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCom 40 pontos de E\/S integrados (24 entradas e 16 saídas), este controlador é essencial em infraestruturas críticas, como estações municipais de bombeamento de água, transportadores de manuseio de materiais e máquinas de embalagem especializadas. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efornece a potência de processamento necessária para reduzir os tempos de ciclo e otimizar o rendimento. Seu design robusto garante alta confiabilidade em ambientes exigentes, minimizando paradas não planejadas e mantendo a estabilidade do sistema em arquiteturas alimentadas por 120\/240 VAC.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epossui uma arquitetura de hardware projetada para versatilidade e expansão.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-930 citation-end-930\"\u003eConta com entradas sink\/source de 24 VDC e saídas de relé altamente duráveis, permitindo a interface direta com diversos dispositivos de campo.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-929 citation-end-929\"\u003eA unidade é alimentada por uma fonte de 120\/240 VAC, eliminando a necessidade de módulos de alimentação DC externos para a operação básica do controlador.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eA comunicação é feita via porta RS-232 isolada, suportando os protocolos DF1, DH-485 e Modbus RTU para integração perfeita em redes SCADA ou HMI existentes. A memória do controlador é baseada em flash, protegendo programas e dados do usuário sem a necessidade absoluta de bateria, embora uma bateria (1747-BA) seja suportada para retenção de dados a longo prazo.\u003c\/p\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModelo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1762-L40BWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarca\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEUA \/ Malásia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTipo de Entrada\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Sink\/Source (24 pontos)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTipo de Saída\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelé (16 pontos)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlimentação\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100-240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemória do Usuário\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 KB (aprox. 4 KB Instrução\/2 KB Dados)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComunicação\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 (mini-DIN de 8 pinos)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperatura de Operação\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 a 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensões\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 x 160 x 87 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeso\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eO 1762-L40BWA suporta expansão de E\/S além dos 40 pontos integrados?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim, a série MicroLogix 1200 suporta até seis módulos de expansão de E\/S 1762. Esses módulos são conectados via cabo flat no lado direito da unidade, permitindo um aumento significativo no número de pontos digitais ou analógicos.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual software é necessário para programar este controlador específico?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé programado usando o software RSLogix 500 ou versões específicas para MicroLogix da mesma suíte. É compatível com ambientes Windows e utiliza uma estrutura padrão de programação em linguagem ladder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo faço para resetar o controlador para as configurações de fábrica se a senha for perdida?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO reset do controlador geralmente requer um procedimento específico de limpeza de memória ou uma \"Senha Mestra\" autorizada pela fábrica, dependendo da versão do firmware. Note que o reset de fábrica apagará toda a lógica ladder armazenada e as tabelas de dados.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurabilidade da Saída de Relé:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara prolongar a vida útil dos contatos internos do relé, sempre instale um circuito de supressão externo (como um snubber RC para cargas AC ou um diodo para cargas DC) ao comutar cargas indutivas como solenóides ou partidas de motor. Isso previne arco elétrico nos contatos e falhas prematuras.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontagem em Trilho DIN e Painel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmbora a unidade suporte montagem em trilho DIN, para ambientes com alta vibração (como britagem de rochas ou estampagem pesada), recomenda-se usar os furos de fixação com parafusos integrados para uma instalação mais segura e direta no painel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento e Redução de Ruído:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssegure que o terminal \"Chassis Ground\" esteja conectado a um aterramento de baixa impedância usando um fio curto e de bitola grossa. Isso é fundamental para proteger a fonte de alimentação de sensores de 24 VDC interna e garantir sinais estáveis de comunicação RS-232 em plantas industriais com alto ruído elétrico.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695188537707,"sku":"1762-L40BWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller-ed4xi5bj2x3_3724e6e5-154e-4b4f-bc96-12ed5d3b362a.jpg?v=1766114546","url":"https:\/\/www.plcprotech.com\/pt\/products\/allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}