{"product_id":"beckhoff-cp6502-0000-0090-cp6502-series-15-inch-built-in-panel-pc","title":"Beckhoff CP6502-0000-0090 CP6502 Series 15-inch Built-in Panel PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for direct integration into control cabinets and operator consoles, the \u003cstrong\u003eBeckhoff CP6502-0000-0090\u003c\/strong\u003e serves as a high-performance industrial Panel PC featuring a brilliant \u003cstrong\u003e15-inch TFT display\u003c\/strong\u003e with a native resolution of \u003cstrong\u003e1024 x 768 pixels\u003c\/strong\u003e. This unit combines robust computing capabilities with an industrial-grade display, utilizing an integrated ATX motherboard chassis designed to withstand harsh manufacturing environments. Featuring \u003cstrong\u003epull-out clamping levers\u003c\/strong\u003e, this device guarantees quick, secure mounting without the risk of loose mounting components inside the electrical enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Display Panel:\u003c\/strong\u003e 15-inch high-visibility screen providing clear graphic representation of process variables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Protection Enclosure:\u003c\/strong\u003e Features a rugged IP65-rated front panel protective seal and an IP20-rated rear enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e Built-in ATX housing designed to accommodate active PCIe\/PCI plug-in card slots.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eToolless Installation:\u003c\/strong\u003e Integrated rear clamping levers facilitate rapid mechanical securing in panel cut-outs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Connectivity:\u003c\/strong\u003e Dual onboard Gigabit Ethernet ports to support separate network zones (e.g., control network and office LAN).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eMachine-level visualization and human-machine interface (HMI) systems.\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines in automotive manufacturing.\u003c\/li\u003e\n  \u003cli\u003eCentralized supervisory control and data acquisition (SCADA) systems.\u003c\/li\u003e\n  \u003cli\u003eProcess monitoring terminals in water treatment and food processing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCP6502-0000-0090\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eDevice Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eBuilt-in Panel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e15-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eHousing Architecture\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eATX layout (7 slot capacity)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eFront Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eRear Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e0 to 55 degC (ambient)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eNetwork Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e2 x 100\/1000BASE-T RJ45 ports\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eSupported Operating Systems\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eWindows 7, Windows Embedded Standard 7, Windows 10 IoT Enterprise\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e9.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 12px 8px; text-align: left; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; text-align: left; font-weight: bold;\"\u003ePhysical Quantity \u0026amp; Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e4 x USB 3.0 (onboard layout), additional USB 2.0 options\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eVideo Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e2 x DVI, 1 x DisplayPort\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eSerial Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eRS232 (configuration dependent)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eKeyboard\/Mouse\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003ePS\/2 connection support\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CP6502 panel geometry features backwards compatibility with older CP65xx cabinet layouts. When swapping out legacy units running older iterations of TwinCAT 2, verify that the runtime driver signatures and licensing models map seamlessly to the operating system configuration of the CP6502-0000-0090.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent thermal throttling in high-ambient environments, ensure a minimum vertical clearance of 50 mm above and below the rear ATX chassis. Avoid mounting the Panel PC directly adjacent to high-power variable frequency drives (VFDs) or switchgear to minimize electromagnetic coupling.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor installations using a 24 V DC supply instead of the 100–240 V AC variant, prioritize an isolated industrial power supply unit (PSU). Connect the frame ground tab on the rear directly to the central control cabinet ground bar using a low-impedance copper strap to optimize noise immunity.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Verify that all upstream power disconnects are locked out and tagged out prior to physical assembly. Ensure all residual electrical charge within power distribution modules is completely dissipated before connecting main power cords or DC supply lines.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConfirm the control panel cutout dimensions conform strictly to the mechanical profile required for 15-inch Beckhoff Panel PCs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the device through the front panel cut-out, making sure the integrated front-gasket seats evenly against the mounting plane.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePull outward and secure the built-in mechanical clamping levers from the rear until the unit is held firmly in place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eEstablish protective earth connection, interface Ethernet and serial buses, and wire the power connection before turning on local power.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106414485867,"sku":"CP6502-0000-0090","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp6502-0000-0090-s22cctikksz.png?v=1776243846","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-cp6502-0000-0090-cp6502-series-15-inch-built-in-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}