{"product_id":"beckhoff-cx1010-0122-cx-series-cpu-module","title":"Beckhoff CX1010-0122 CX Series CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eArchitected as the central processing unit for modular control environments, the Beckhoff CX1010-0122 system module integrates an Intel Pentium MMX-compatible processor running at 500 MHz to handle basic PLC and motion control execution. This module functions as the execution core within a DIN-rail mounted control cluster, offering robust performance for legacy industrial networks and machine-level control systems. Equipped with 256 MB of non-expandable DDR RAM and an active Compact Flash Type II expansion slot, the CPU delivers deterministic processing capabilities when integrated with TwinCAT software control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Efficiency Execution:\u003c\/strong\u003e Equipped with a 500 MHz Pentium MMX-compatible processor tailored for entry-level PLC and basic NC tasks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCompact Storage:\u003c\/strong\u003e Features an accessible Compact Flash Type II slot with an integrated ejector, packaged with a 128 MB CF card.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eEthernet Connectivity:\u003c\/strong\u003e Built-in 10\/100 Mbit\/s RJ45 port for direct industrial networking and programming access.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Five local LEDs provide direct hardware feedback for power, network speed, activity, TwinCAT status, and flash card access.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFlexible Bus Compatibility:\u003c\/strong\u003e Interfaces with K-bus, E-bus, and IP-Link I\/O systems via compatible power supply modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMachine tool control and small-scale automation lines.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eBuilding automation substations and HVAC management systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMaterial handling, sorting systems, and conveyor line control.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eLegacy system migration and drop-in replacements for older CX series control racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCX1010-0122\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntel Pentium MMX compatible, 500 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Cores\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMain Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e256 MB DDR RAM (non-expandable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFlash Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCompact Flash Type II slot (128 MB CF card included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNetwork Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x RJ45 10\/100 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSystem Bus Link\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16-bit ISA (PC\/104)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVia system bus (through connected CX1100-xxxx modules)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax. Power Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDiagnostic Indicators\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x power, 1 x LAN speed, 1 x LAN activity, 1 x TC status, 1 x flash access\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInternal Clock\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBattery-backed clock for date and time (battery replaceable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWindows Embedded CE 6 \/ Windows Embedded Standard 2009\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTwinCAT 2 PLC runtime or TwinCAT 2 NC PTP runtime\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to +50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e95%, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVibration\/Shock Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eApprovals\/Markings\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e58 mm x 120 mm x 91 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eApprox. 355 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 kg (including protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe hardware architecture of this CPU module demands specific maintenance considerations and configuration knowledge to ensure uninterrupted operation in industrial installations.\u003c\/p\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis CPU module belongs to the legacy CX1010 hardware line. When replacing an older generation unit, verify your TwinCAT 2 license keys, as they are hard-coded to the unique System ID of the CPU. Upgrading to the higher-performance CX1020 or CX5100 series will require physical dimension adjustments on the DIN rail and project migration within TwinCAT 2.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe module relies on entirely passive, fanless cooling. To prevent thermal throttling under high CPU utilization, do not block the air vents on the top and bottom of the housing. Maintain a minimum vertical clearance of 30 mm inside the electrical enclosure. Additionally, ensure that only SLC-type (Single-Level Cell) Compact Flash cards are used for the OS partition, as multi-level cell cards can experience premature failure due to continuous OS read\/write cycles.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis CPU has no direct power terminals on its faceplate. It relies entirely on a connected CX1100-xxxx series power supply module. Ensure that the PC\/104 system bus connector pins are straight and clean before joining the CPU to the power supply module. Misaligned pins during assembly can cause immediate system bus failure or permanent damage to the CPU motherboard when energized.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e \u003cspan style=\"color: #2d3748;\"\u003eNever mount, demount, or adjust connections on the CPU assembly while the system is powered. Ensure all supply lines to connected CX1100 power supply modules and associated I\/O modules are completely de-energized to prevent current spikes and potential system bus destruction.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n    Position the CPU module onto the 35 mm DIN rail next to the corresponding CX1100 power supply module, ensuring the PC\/104 connectors align precisely.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n    Firmly push the modules together until they click into place on the rail, securing the mechanical latch to prevent shifting.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n    Insert the pre-configured Compact Flash card containing the system software into the Type II slot before initiating power-on sequence.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n    Connect the RJ45 industrial Ethernet cable to the native port to establish communications, then apply power via the main supply module.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106441453931,"sku":"CX1010-0122","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx1010-0122-pn5wqikz14g.png?v=1776244113","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-cx1010-0122-cx-series-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}