{"product_id":"beckhoff-ep2809-0022-ethercat-box-16-channel-digital-output-module","title":"Beckhoff EP2809-0022 EtherCAT Box 16-channel Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing digital control signals directly in the field, the \u003cstrong\u003eBECKHOFF EP2809-0022\u003c\/strong\u003e distributes sixteen binary control commands from the EtherCAT network to actuators with minimal propagation delay. This ultra-compact \u003cstrong\u003eEtherCAT Box\u003c\/strong\u003e module bypasses the electrical cabinet, allowing direct machine mounting in harsh industrial environments. By providing sixteen independent, short-circuit proof outputs on M12 connection ports, the device optimizes signal routing and reduces wiring overhead in highly distributed automation layouts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density I\/O:\u003c\/strong\u003e 16 digital outputs integrated into a compact, space-saving IP67 enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Channel Protection:\u003c\/strong\u003e Individually short-circuit proof outputs with up to 0.5 A load capacity per channel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEtherCAT Direct Interface:\u003c\/strong\u003e Direct coupling to high-speed industrial networks via shielded M8 screw-type connectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic Load Compatibility:\u003c\/strong\u003e Engineered to reliably switch ohmic, inductive, and lamp loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Diagnostics:\u003c\/strong\u003e Run-status LEDs and channel-specific status indicators for accelerated troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized conveyor control and sorting systems\u003c\/li\u003e\n  \u003cli\u003ePneumatic valve manifold pilot driving\u003c\/li\u003e\n  \u003cli\u003eDistributed packaging machinery actuation\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines and pick-and-place systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eTechnical Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBECKHOFF\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEP2809-0022\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtocol Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEtherCAT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax. Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 A per channel (individually short-circuit proof, total max. 4 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSwitching Times\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTypical TON: 60 microseconds, Typical TOFF: 300 microseconds\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBus Connection Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 x M8 socket, shielded, screw type\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eM12 x 1, 5-pin, A-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Feed Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e500 V (E-bus \/ signal voltage)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP65, IP66, IP67 (conforming to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEMC Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eApprovals \u0026amp; Markings\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eapprox. 250 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePin \/ Terminal Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; rowspan=4; font-weight: bold;\"\u003eM8 Power Feed (4-pin)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+24 V DC Control Power (US)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+24 V DC Load Power (UP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGND (US)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGND (UP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; rowspan=3; font-weight: bold;\"\u003eM12 Outputs (5-pin, A-coded)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2 \/ Pin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDigital Output Channel A \/ Channel B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGND (UP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFunctional Earth (FE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe EP2809-0022 features M12 outputs, offering a more robust alternative to standard EP2809-0001 flat ribbon connection modules. Always verify your field cabling layout before drop-in replacement, as connection interfaces change from M8 output terminals to consolidated 5-pin M12 outputs carrying dual switching channels per port.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThermal accumulation must be accounted for in high-duty cycle layouts. While each output is rated for up to 0.5 A, the aggregate current limit of the module is capped at 4.0 A. Exceeding this thermal threshold will trigger internal short-circuit protection and shut down the affected output blocks. When driving high-inductance solenoids, ensure cycle frequencies allow sufficient time for back-EMF dissipation.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eMaintaining IP67 structural integrity requires torque-sealing every unused connection. Always utilize physical screw-on protective caps for unpopulated M12 sockets. To prevent communications dropout within the EtherCAT run, ensure all power line cabling uses separate routing pathways from high-frequency variable frequency drive output cables.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL FIELD WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before initiating installation, removal, or wiring modifications on the Beckhoff module. Failure to de-energize primary and auxiliary power supplies (US and UP) may result in severe equipment damage, incorrect physical output triggering, or persistent communication faults along the active EtherCAT segment.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePhysical Mounting:\u003c\/strong\u003e Secure the EtherCAT Box onto a flat surface or machine profile frame using M3 screws. Ensure all mounting holes are correctly aligned to avoid physical strain on the module's polymer housing.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eNetwork Wiring:\u003c\/strong\u003e Connect the incoming EtherCAT run to the left-hand M8 \"IN\" port and direct the downstream chain from the \"OUT\" port to the subsequent EtherCAT node using shielded industrial Ethernet cables.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePower Integration:\u003c\/strong\u003e Apply 24 V DC control power (US) and actuator load power (UP) to the designated M8 power socket. Chain the power to adjacent modules as required, adhering strictly to current carrying limits.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eActuator Connections:\u003c\/strong\u003e Wire the actuator terminals using standard 5-pin, A-coded M12 cable assemblies. Fully tighten all locking collars to verify reliable connection contacts and to preserve the IP67 protection rating.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106526552427,"sku":"EP2809-0022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep2809-0022-wyau0s1rexq.png?v=1776244661","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-ep2809-0022-ethercat-box-16-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}