{"product_id":"beckhoff-ep2816-0004-ethercat-box-digital-output-module","title":"BECKHOFF EP2816-0004 EtherCAT Box Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized automation tasks in harsh environments, the Beckhoff \u003cstrong\u003eEP2816-0004\u003c\/strong\u003e is a high-density \u003cstrong\u003edigital output module\u003c\/strong\u003e that interfaces directly with the EtherCAT network. This fieldbus-level device features 16 digital channels packaged in a compact, IP67-rated housing. It is engineered to switch binary control signals from the automation controller to actuators, solenoids, or indicators on the machine. By utilizing an M16, 19-pin output connector, the \u003cstrong\u003eEP2816-0004\u003c\/strong\u003e provides a centralized wiring point, making it highly compatible with multi-pin connector valve terminals.\u003c\/p\u003e\n\n\u003cp\u003eThe module operates on a nominal 24 V DC control voltage and handles up to 0.5 A per output channel. Each channel is designed with individual short-circuit protection to protect local wiring and system backplanes from overcurrent faults. With integrated support for Distributed Clocks, this EtherCAT Box guarantees highly synchronized signal processing across industrial installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 digital output channels in a robust, space-saving design.\u003c\/li\u003e\n  \u003cli\u003eCentralized M16 19-pin output connector, optimizing connection to multi-pin valve manifolds.\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof outputs rated at 0.5 A per channel (total sum current of 4 A).\u003c\/li\u003e\n  \u003cli\u003eHigh-speed switching times with a typical turn-on time of 25 us and turn-off time of 50 us.\u003c\/li\u003e\n  \u003cli\u003eDistributed Clocks integration ensures precise synchronization with the central PLC controller.\u003c\/li\u003e\n  \u003cli\u003eRugged IP65\/66\/67 construction enables direct machine mounting without an electrical enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePneumatic valve terminal integration in industrial packaging lines.\u003c\/li\u003e\n  \u003cli\u003eDecentralized control of solenoids and actuators in automotive assembly.\u003c\/li\u003e\n  \u003cli\u003eOn-machine I\/O distribution for manufacturing machinery with limited enclosure space.\u003c\/li\u003e\n  \u003cli\u003eWater treatment facilities and process control operations requiring high environmental resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eEP2816-0004\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtocol\u003c\/strong\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBus Interface\u003c\/strong\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOutput Connections\u003c\/strong\u003e\n      \u003ctd\u003eM16 socket, 19-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLoad Type\u003c\/strong\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof), sum max. 4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSwitching Times\u003c\/strong\u003e\n      \u003ctd\u003etyp. T_ON: 25 us, typ. T_OFF: 50 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\n      \u003ctd\u003emax. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDistributed Clocks\u003c\/strong\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCurrent Consumption from US\u003c\/strong\u003e\n      \u003ctd\u003e120 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAuxiliary Power Current\u003c\/strong\u003e\n      \u003ctd\u003etyp. 20 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Supply Connection\u003c\/strong\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Rating\u003c\/strong\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003eapprox. 165 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector Style\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Bus\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded\u003c\/td\u003e\n      \u003ctd\u003eInbound and outbound industrial Ethernet communications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 x M16, 19-pin socket\u003c\/td\u003e\n      \u003ctd\u003eUnified connection for 16 digital control channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Feed\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePrimary 24 V DC supply input (US\/UP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Downstream\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower pass-through to daisy-chained EtherCAT Box modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module directly to the machine frame or mounting plate using appropriate M3 screws. Ensure the mounting surface is flat to prevent mechanical stress on the housing.\u003c\/li\u003e\n  \u003cli\u003eTo maintain the IP67 protection rating, ensure all unused M8 and M16 connectors are sealed with corresponding protective caps.\u003c\/li\u003e\n  \u003cli\u003eEstablish a reliable ground connection via the metal mounting surface or the functional earth connection point on the module.\u003c\/li\u003e\n  \u003cli\u003eObserve the maximum allowable sum current of 4 A across all 16 channels to prevent internal power path overload.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106527535467,"sku":"EP2816-0004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep2816-0004-siod1vaffyt.png?v=1776244664","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-ep2816-0004-ethercat-box-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}