{"product_id":"beckhoff-ip2002-b518-fieldbus-box","title":"Beckhoff IP2002-B518 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Designed for direct, machine-mount distributed deployment, the \u003cstrong\u003eBeckhoff IP2002-B518\u003c\/strong\u003e coordinates high-density localized outputs without the footprint or cost of protective control enclosures. This decentralized fieldbus box integrates 8 digital outputs operating at 24 V DC, utilizing \u003cstrong\u003eCANopen\u003c\/strong\u003e protocol communications to optimize real-time control architectures. With integrated M12 T-junction connectors, this device enables clean line-topology bus configurations directly on physical machine frames. Wrapped in a ruggedized polyamide housing, it delivers reliable IP67 protection against moisture, dust, and continuous industrial vibrations.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 Digital Outputs:\u003c\/strong\u003e Delivers up to 0.5 A per channel, fully compatible with resistive, inductive, and lamp load setups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated T-Connector:\u003c\/strong\u003e Built-in M12 5-pin male and female connectors enable straightforward physical looping of the CANopen bus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Circuit Diagnostics:\u003c\/strong\u003e Individual output channels feature electronic short-circuit protection to insulate localized faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Power Distribution:\u003c\/strong\u003e Dedicated M8 connections isolate control logic power (Us) from physical load power (Up).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAggressive Environmental Rating:\u003c\/strong\u003e Rated for IP65\/66\/67 operation, securing signal paths in high-spray washdown zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePneumatic Valve Block Control:\u003c\/strong\u003e Direct switching of manifold pilot valves on moving gantry assemblies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling Conveyors:\u003c\/strong\u003e Localized routing of sorting diverters, stop gates, and indicator lights.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Tooling:\u003c\/strong\u003e Robotic end-effector output distribution where control enclosure space is non-existent.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging and Bottling Machinery:\u003c\/strong\u003e Multi-station actuator triggering in high-moisture production zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP2002-B518\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8-Channel Digital Output Fieldbus Box\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtocol \/ Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCANopen (16 Tx \/ 16 Rx PDOs supported)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSupported Baud Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10 kbaud to 1 Mbaud (automatic detection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8 (single-wire connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax. Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e500 V (Control voltage to fieldbus)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Voltage Supply (Us)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC, typical 45 mA current consumption\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFieldbus Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (Integrated T-Connector)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Feed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x M8 male (4-pin); Downstream loop: 1 x M8 female (4-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePolyamide PA6 (XXL housing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 2.0 kg;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eConnector \/ Interface\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePin Number\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSignal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"5\" style=\"padding: 10px; font-weight: bold; vertical-align: top;\"\u003eCANopen Fieldbus (M12)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN_SHLD (Shield)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eV+ (Optional External Power)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN_GND (Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN_H (Signal High)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN_L (Signal Low)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"4\" style=\"padding: 10px; font-weight: bold; vertical-align: top;\"\u003ePower Supply Feed (M8)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUs +24 V DC (Control Voltage for Electronics)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUp +24 V DC (Load Voltage for Digital Outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGNDs (Control Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGNDp (Load Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The B518 variant serves as an drop-in optimization over legacy B510 fieldbus boxes. Because the IP2002-B518 integrates the T-connector directly within its molded housing, it completely replaces the requirement for external \"Z1001\" network splitter adapters, decreasing field cabling clutter and potential points of ingress failure.\n\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  While each individual channel features short-circuit current protection peaking at approximately 1.5 A under fault conditions, the cumulative load across all 8 output channels must not exceed the maximum current rating of the feeding M8 terminal (typically capped at 4 A total across Up). Ensure appropriate current-budget configurations are calculated for simultaneously active inductive loads.\n\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To access the decimal rotary node-ID configuration switches, remove the protective cover plate using a small flat screwdriver. Ensure this plate is re-seated with its sealing gasket completely flush to preserve the IP67 integrity. Additionally, note that this module does not integrate internal CAN termination resistors; a physical M12 termination plug must be added at the terminal physical drop-point of the network.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure all power distribution lines (Us and Up) are fully de-energized prior to connecting or disconnecting any M8 or M12 cables. Connecting active power lines to IP-series modules can result in contact-arc damage and compromise internal diagnostic logic.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Mount the module directly onto a flat machinery support structure using the two 3.5 mm diameter fixing points using M3 screws. Ensure no torsional stress is applied to the PA6 housing.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eConfigure Node ID:\u003c\/strong\u003e Unscrew the protective cover. Using a rotary switch tool, set the correct CANopen Node ID. Verify the baud rate setting is configured correctly (defaulting to auto-detection). Re-seal the cover.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eBus \u0026amp; I\/O Connections:\u003c\/strong\u003e Connect the M12 fieldbus lines to the integrated T-connector ports. Tighten the knurled metal collars hand-tight (0.6 Nm torque recommended) to guarantee environmental protection.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePower Integration:\u003c\/strong\u003e Hook up the incoming 4-pin M8 feed. If multiple boxes are in line, loop from the downstream M8 female connector to the subsequent device.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106457379179,"sku":"IP2002-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2002-b518-hcnmhh4vmcw.png?v=1776244929","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-ip2002-b518-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}