{"product_id":"beckhoff-ip2301-b400-fieldbus-box-digital-i-o-module","title":"Módulo de E\/S Digital BECKHOFF IP2301-B400 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for direct installation in demanding industrial environments without a control cabinet, the \u003cstrong\u003eIP2301-B400\u003c\/strong\u003e provides a robust interface between \u003cstrong\u003eInterbus\u003c\/strong\u003e networks and decentralized field sensors or actuators. This \u003cstrong\u003efieldbus box\u003c\/strong\u003e features a balanced combination of four digital inputs and four digital outputs in a compact, IP67-rated housing. By routing physical signals directly at the machine level, the module significantly minimizes wiring overhead, simplifies diagnostics, and optimizes signal propagation times.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated digital inputs feature a 3 ms filter time to prevent contact bounce issues, while the short-circuit-proof digital outputs deliver up to 0.5 A per channel. Standardized M8 connectors ensure secure, vibration-resistant sensor and actuator cabling, making this unit highly suitable for dynamic mechanical setups.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect Interbus fieldbus connection for high-speed decentralized communication.\u003c\/li\u003e\n  \u003cli\u003eFour digital inputs (24 V DC) with an integrated 3 ms input filter.\u003c\/li\u003e\n  \u003cli\u003eFour short-circuit proof digital outputs rated at 0.5 A per channel.\u003c\/li\u003e\n  \u003cli\u003eCompact, space-saving design with robust M8 connection technology.\u003c\/li\u003e\n  \u003cli\u003eIP67 protection class allowing direct mounting on machines without protective enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine control and plant automation architectures.\u003c\/li\u003e\n  \u003cli\u003eAutomotive manufacturing assembly lines utilizing Interbus fieldbus networks.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, packaging machinery, and conveyor line routing.\u003c\/li\u003e\n  \u003cli\u003eIndustrial robotics and end-of-arm tooling control setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2301-B400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol \/ Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInterbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 digital inputs (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 digital outputs (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 screw connectors (I\/O)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg (approximate package weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eM8 Connector Pin\u003c\/th\u003e\n      \u003cth\u003eInput Channel Function\u003c\/th\u003e\n      \u003cth\u003eOutput Channel Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin 1\u003c\/td\u003e\n      \u003ctd\u003e+24 V DC Sensor Supply\u003c\/td\u003e\n      \u003ctd\u003eNot Connected \/ Free\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin 3\u003c\/td\u003e\n      \u003ctd\u003e0 V (GND)\u003c\/td\u003e\n      \u003ctd\u003e0 V (GND)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin 4\u003c\/td\u003e\n      \u003ctd\u003eInput Signal\u003c\/td\u003e\n      \u003ctd\u003eOutput Signal (0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module directly to a flat machine frame or structure using the integrated mounting holes.\u003c\/li\u003e\n  \u003cli\u003eEnsure reliable grounding of the module case to the machinery frame to maximize electromagnetic compatibility (EMC).\u003c\/li\u003e\n  \u003cli\u003eTighten all M8 mating connectors to the recommended torque specifications to maintain the IP67 environmental seal.\u003c\/li\u003e\n  \u003cli\u003eRoute fieldbus and low-voltage control lines separate from high-noise power cables or AC motor drives to prevent signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106452693355,"sku":"IP2301-B400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2301-b400-5v5iizn2233.png?v=1776244994","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-ip2301-b400-fieldbus-box-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}