{"product_id":"beckhoff-ip2310-b310-fieldbus-box-4-channel-input-output-module","title":"Módulo de Entrada\/Saída de 4 Canais Beckhoff IP2310-B310 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized signal acquisition on the factory floor is handled efficiently by the \u003cstrong\u003eBeckhoff IP2310-B310\u003c\/strong\u003e Fieldbus Box. This robust distributed I\/O module integrates \u003cstrong\u003e4 digital inputs\u003c\/strong\u003e and \u003cstrong\u003e4 digital outputs\u003c\/strong\u003e directly into a high-speed \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e network without requiring an IP20 protective enclosure. Designed for direct machine-mounting, the device processes rapid digital signals with a 0.2 ms filter constant while offering high protection against environmental moisture and particulates. The \u003cstrong\u003eBeckhoff IP2310-B310\u003c\/strong\u003e enables engineers to minimize control cabinet space and drastically reduce field-level wiring complexity by mounting the control interfaces directly on the mechanical structure.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFIBUS DP Interface:\u003c\/strong\u003e High-performance fieldbus coupling with automatic baud rate detection up to 12 Mbaud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized I\/O Density:\u003c\/strong\u003e Configured with 4 digital inputs (24 V DC) and 4 digital outputs (24 V DC, 0.5 A short-circuit protected).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Machine Integration:\u003c\/strong\u003e IP67-rated enclosure protects internal components against water jets, dust, and particulate contamination.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact M8 Connections:\u003c\/strong\u003e Direct physical linkage for industrial sensors and actuators utilizing compact M8 (dia 8 mm) circular plug connectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Diagnostics:\u003c\/strong\u003e Dedicated LED indicators showing fieldbus status, power supply status, and individual channel activity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eAutomotive assembly lines and robotic welding cells requiring decentralized tool-tip logic.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling networks with widely distributed proximity sensors and pneumatic solenoids.\u003c\/li\u003e\n  \u003cli\u003eFood processing and packaging machines exposed to frequent washdown procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBECKHOFF\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP2310-B310\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFieldbus System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePROFIBUS DP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 x 24 V DC (Filter: 0.2 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 x 24 V DC (0.5 A per channel, short-circuit proof)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eControl Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSensor Supply Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMax. 0.5 A sum total for all sensors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eI\/O Connection Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eM8 (dia 8 mm) screw-lock \/ snap-in connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 degC to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 degC to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP67\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eM8 Connector Pin\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eInput Port Function\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eOutput Port Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+24 V DC Sensor Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNot Connected \/ Reserve\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND (0 V)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND (0 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eInput Signal (Ch 1 - 4)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eOutput Signal (Ch 1 - 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen migrating legacy systems, note that the IP2310-B310 uses the PROFIBUS DP standard protocol and relies on specific GSD files (typically \u003ccode\u003eI2310B31.gsd\u003c\/code\u003e) during PLC hardware configuration. If replacing this module with newer EtherCAT-based options like the EP2318-0001, complete changes to the master controller configuration and physical cabling infrastructure are mandatory.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlthough the output channels are short-circuit protected and rated for 0.5 A each, the total combined current of the module's sensor supplies must not exceed 0.5 A. Deploying multiple high-draw photo-eye sensors without supplementary external distribution blocks will trip the internal thermal fuses. Ensure inductive load suppression (e.g., flyback diodes) is integrated externally when driving high-inductance pneumatic solenoids to prevent premature degradation of the solid-state output circuitry.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor robust PROFIBUS communication at rates exceeding 1.5 Mbaud, ensure that both physical ends of the PROFIBUS segment are properly terminated with active 220-ohm pull-up termination resistors. Keep the standard M8 sensor lines under 3 meters to prevent inductive coupling and high-frequency noise interference from adjacent variable frequency drive (VFD) cables.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL SAFETY WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c; font-size: 0.95rem;\"\u003eBefore starting physical mounting, wiring, or maintenance on the PROFIBUS network, isolate all electrical power supplies. Disconnect both the control power (Us) and peripheral load power (Up) channels. Failure to de-energize can lead to accidental actuator actuation or severe communication dropouts due to transient ground loops.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003ePosition the module flat against a clean, vibration-resistant machine frame structure. Securely tighten both mounting screws (M4 size) using an appropriate torque limit of 1.2 Nm to guarantee mechanical grounding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the incoming PROFIBUS and local power distribution cabling. Verify that all unused M12 and M8 connector sockets are sealed with official IP67 protective caps to keep out environmental moisture.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eAdjust the rotary hardware address switches on the front face of the module to align exactly with the assigned node address configured inside your central PLC hardware configuration tool.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106463375723,"sku":"IP2310-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2310-b310-noe5gb0pfvx.png?v=1776245009","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-ip2310-b310-fieldbus-box-4-channel-input-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}