{"product_id":"beckhoff-kl3062-bus-terminal","title":"BECKHOFF KL3062 Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eProcessing analog input signals in the 0 to 10 V range, the \u003cstrong\u003eBECKHOFF KL3062\u003c\/strong\u003e Bus Terminal features two single-ended channels designed for direct connection to industrial sensors and transmitters. This compact input module converts analog physical values into digital signals with a 12-bit resolution, ensuring reliable signal transmission to the higher-level automation controller via the K-bus. Utilizing a common internal ground connection for both channels, the terminal minimizes wiring complexity in standard control cabinet installations.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eKL3062\u003c\/strong\u003e provides comprehensive galvanic isolation up to 500 V between the input circuitry and the internal K-bus. Operating without the need for dedicated power contacts, the terminal derives its required operating power directly from the K-bus interface. The robust IP20 design and standard DIN rail mounting compatibility make it suitable for seamless integration in complex PLC and DCS architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo independent analog input channels.\u003c\/li\u003e\n  \u003cli\u003eSingle-ended measurement technology sharing a common reference ground.\u003c\/li\u003e\n  \u003cli\u003eStandard 0 to 10 V signal voltage range.\u003c\/li\u003e\n  \u003cli\u003e12-bit analog-to-digital resolution.\u003c\/li\u003e\n  \u003cli\u003eIntegrated galvanic electrical isolation up to 500 V (K-bus to signal voltage).\u003c\/li\u003e\n  \u003cli\u003eFast conversion time of approximately 2 ms.\u003c\/li\u003e\n  \u003cli\u003eLow power consumption directly from the K-bus (typically 60 mA).\u003c\/li\u003e\n  \u003cli\u003eNo address or hardware configuration required prior to commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial process control and monitoring systems.\u003c\/li\u003e\n  \u003cli\u003ePneumatic and hydraulic valve position feedback.\u003c\/li\u003e\n  \u003cli\u003eIntegration with pressure transmitters, flow meters, and distance sensors.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and machine building installations.\u003c\/li\u003e\n  \u003cli\u003eHazardous area applications requiring compliant ATEX\/IECEx intrinsically safe parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKL3062\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVia the K-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. \u0026gt; 200 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption K-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 60 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBit Width in Process Image\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInput: 2 x 16 bit data (2 x 8 bit control\/status optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo address or configuration setting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEx Marking\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eATEX: II 3 G Ex ec IIC T4 Gc, IECEx: Ex ec IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Point\u003c\/th\u003e\n      \u003cth\u003eFunction Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input 1 (+)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input 2 (+)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 V (Reference ground for Input 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 V (Reference ground for Input 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShield connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShield connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the module directly onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism engages securely.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire sizes with terminal connectors. For solid or stranded wires, ensure the maximum cross-section conforms to the terminal blocks' limit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Connect the analog cable shields to terminal points 4 or 8 to prevent electrostatic and electromagnetic interference from disrupting signal integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is grounded to a low-impedance earth system in compliance with standard electrical installation codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX (II 3 G Ex ec IIC T4 Gc)\u003c\/li\u003e\n  \u003cli\u003eIECEx (Ex ec IIC T4 Gc)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106497061227,"sku":"KL3062","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl3062-ywtra1lkpg1.png?v=1776245155","url":"https:\/\/www.plcprotech.com\/pt\/products\/beckhoff-kl3062-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}