{"product_id":"bently-nevada-165855-12-cn-cylinder-pressure-transducer","title":"Bently Nevada 165855-12-CN Cylinder Pressure Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for precise dynamic cylinder pressure monitoring, the \u003cstrong\u003eBently Nevada 165855-12-CN\u003c\/strong\u003e provides reliable measurement capabilities within reciprocating compressor diagnostic systems. This device translates mechanical pressure changes into highly accurate electrical signals, enabling real-world thermodynamic analysis and machinery protection. Equipped with integrated protective armor, it withstands the harsh operational environments typical of heavy industrial engine and compressor manifolds.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Protective Armor:\u003c\/strong\u003e Built-in steel armor guards the transducer cable against physical impacts and thermal wear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStable Electrical Interface:\u003c\/strong\u003e Standardized 18 to 30 Vdc input voltage compatibility allows seamless system integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalog Voltage Feedback:\u003c\/strong\u003e High-precision scaling ensures clear diagnostic data transfer over long cable runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegional Compliance:\u003c\/strong\u003e Verified under specific CN agency approval parameters for reliable site certification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eContinuous reciprocating compressor cylinder monitoring\u003c\/li\u003e\n  \u003cli\u003eThermodynamic performance evaluation of industrial engines\u003c\/li\u003e\n  \u003cli\u003eMachinery protection and early fault detection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e165855 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFull SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e165855-12-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePressure Range Option (12)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 17 bar (0 to 250 psia) with armored cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAgency Approval (CN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCountry-specific certifications\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFull Scale Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10 +\/- 0.3 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eZero Reference Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 +\/- 0.1 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e18 to 30 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Instrument Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.4 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCalculated Shipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The \"12\" range option (0 to 17 bar) is specifically designed for low-to-medium pressure industrial cylinders. If replacing a standard unarmored transducer, verify that structural clearance supports the slightly stiffer profile of the armored cable.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e Because pressure transients in reciprocating compressors can cause rapid thermal spikes, the sensor must be mounted in accordance with thermal-isolation specifications. Do not exceed the 17 bar threshold; transient spikes beyond the rated dynamic range may compromise zero-point stability.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e Ensure the power supply is dedicated and free of high-frequency noise. Use high-quality shielding connected at the monitoring system side only to prevent ground loop currents from interfering with the 0.5 to 10 Vdc signal path.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL SAFETY WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate, depressurize, and vent the cylinder before attempting transducer installation or replacement. Verify zero static line pressure within the chamber. Ensure all electrical power supplies to the associated monitoring loop are de-energized to prevent ignition risks in classified environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eInspect the mounting port and clean all thread paths to remove any carbon buildup or previous thread sealant residues.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eApply a thin layer of manufacturer-approved high-temperature thread lubricant, ensuring no lubricant blocks the sensor face or internal pathway.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eThread the transducer by hand to avoid cross-threading, then torque to the manufacturer specified limit using a calibrated wrench.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSecure the armored cabling to structural supports using soft-jaw clamps, avoiding tight bends and direct contact with high-vibration engine components.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668315763051,"sku":"165855-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/165855-12-cn-t01d1015o0r_8fc9aab3-3665-4446-a0e6-df9b56aa173b.jpg?v=1765521012","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-165855-12-cn-cylinder-pressure-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}