{"product_id":"bently-nevada-176449-04-3500-45-position-monitor-1","title":"Bently Nevada 176449-04 Monitor de Posição 3500\/45","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma placa de instrumentação de alta integridade com 4 canais desenvolvida para o sistema de proteção de máquinas padrão da indústria\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500 Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Operando como um monitor de posição especializado, esta placa processa sinais de entrada dinâmicos de sondas de proximidade, Transdutores de Posição Rotativos (RPTs), potenciômetros rotativos e Transformadores Diferenciais Lineares Variáveis (LVDTs) tanto AC quanto DC. Ambientes críticos de processos contínuos — como usinas termelétricas de base, refinarias petroquímicas e operações pesadas de mineração — dependem do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara rastrear movimentos macro-mecânicos em ativos críticos de turbomáquinas. Monitorando parâmetros como posição de empuxo axial, expansão diferencial, expansão da carcaça e posições de válvulas, ele fornece alertas precoces de desvios estruturais. Essa supervisão contínua aciona comandos automáticos de desligamento durante mudanças mecânicas inseguras, protegendo ativos rotativos pesados e reduzindo drasticamente o tempo de inatividade não programado dos ativos.\u003c\/p\u003e\n\u003ch3\u003eArquitetura Mecânica \u0026amp; Avaliação de Sinal\u003c\/h3\u003e\n\u003cp\u003eA infraestrutura de hardware, a estrutura de compatibilidade multi-transdutor e a lógica do algoritmo do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuporta configurações flexíveis de diagnóstico de máquinas:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlocação de Canais Emparelhados:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGerencia dados em quatro canais independentes programados em pares, permitindo que o módulo execute até duas funções de posição distintas simultaneamente (por exemplo, canais 1 e 2 processando posição axial enquanto canais 3 e 4 monitoram a posição da válvula).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Versátil para Transdutores:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePossui redes de condicionamento de entrada selecionáveis por software a bordo que ajustam perfeitamente a impedância de entrada interna e os perfis de excitação para combinar com diversas tecnologias de hardware de sensores.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoramento de Limiar em Dois Níveis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigura pontos de alerta individuais e configuráveis para todas as variáveis medidas ativas, juntamente com níveis de disparo de perigo personalizáveis atribuídos a quaisquer dois variáveis críticas designadas por par de canal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGravação de Telemetria Independente:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFornece saídas isoladas individuais de gravador analógico +4 a +20 mA para canais separados, permitindo rastreamento confiável por redes externas DCS e SCADA sem distorcer os loops principais de proteção.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnóstico de Falhas em Alta Velocidade:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExecuta varreduras diagnósticas internas com velocidade de atualização de 100 ms ou menos, verificando a integridade do caminho do sinal analógico e alterando os estados dos LEDs locais se ocorrer uma falha no transdutor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReferências Físicas e de Desempenho\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro de Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValor Industrial Certificado\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIdentidade do Modelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-04 (3500\/45)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFabricante da Marca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinha de Sistema de Controle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSistema de Proteção de Máquinas 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClassificação do Módulo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor de Posição Contínua de 4 Canais\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOpções de Transdutor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximidade, RPT, Potenciômetro Rotativo, AC\/DC LVDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMáximo de Canais\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Entradas de Sinal por Cartão\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSaída de Corrente Analógica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLoops de Gravador de Corrente Analógica +4 a +20 mA (Carga de 0 a 600 Ohms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolução do Loop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,3662 uA por bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTaxa de Atualização da Telemetria\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 ms ou menos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,6 a 8,5 Watts Típicos (Dependente do Transdutor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 a +65 °C Faixa Térmica Ambiente\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso Físico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 kg Peso Líquido da Base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensões Externas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm A x 24,4 mm L x 241,8 mm P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem da Fabricação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinden, Nevada, EUA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Proteção e Configuração de Máquinas\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo os operadores atribuem funções mecânicas diversas nos quatro canais de entrada?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOs canais do monitor são programados em pares usando o Software de Configuração 3500 Rack. Os canais 1 e 2 podem executar uma função específica — como expansão diferencial de rampa única padrão — enquanto os canais 3 e 4 executam o mesmo perfil ou uma configuração totalmente separada, como posição de válvula ou expansão da carcaça.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuais variações de alimentação ocorrem dentro do monitor ao alternar entre tipos de transdutores?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO consumo interno de energia varia dependendo do subcartão de interface I\/O selecionado. Ele consome tipicamente 7,7 Watts ao usar I\/O de Posição padrão, sobe para 8,5 Watts típicos sob cargas AC LVDT I\/O e cai para 5,6 Watts típicos ao ler layouts de Potenciômetro Rotativo de baixa potência.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComo o 176449-04 responde a curtos-circuitos externos em seus loops de gravador?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO módulo integra isolamento eletrônico completo contra curto-circuito em todas as linhas individuais de saída do gravador de +4 a +20 mA. Se ocorrer um curto-circuito externo ou falha de fiação em um loop de registro a jusante, a lógica principal de proteção da máquina e as tarefas primárias de detecção de alarme continuam operando sem interrupção.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAjuste da excitação do transdutor e otimização da tensão Gap:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAntes de fixar o monitor 176449-04 no rack 3500, verifique se o módulo I\/O do backplane correspondente corresponde ao seu tipo físico de sensor de campo. Para sondas de proximidade, verifique se a alimentação do sensor fornece uma excitação estável de -24 VDC, enquanto os links AC LVDT requerem uma portadora senoidal precisa de 2,3 Vrms a 3400 Hz. Para configurações de empuxo axial e expansão diferencial, posicione a ponta da sonda de campo para ler a tensão exata do ponto central mecânico, alinhando-se com as margens de tensão DC Gap especificadas pela fábrica para maximizar a faixa geral de medição linear do sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMétodos de aterramento da blindagem e mitigação de ruído:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePasse toda a fiação do transdutor de campo por cabos individuais de par trançado blindado, mantendo as linhas de sinal de posição bem afastadas dos terminais de alta potência ou cabos de controle de motor VFD. Termine a malha de blindagem externa de cobre apenas nas barras de aterramento do sistema designadas localizadas dentro do rack do gabinete do instrumento 3500. Deixe a blindagem flutuante e bem isolada na caixa de terminação do sensor de campo para evitar que correntes de loop de terra introduzam ruído elétrico nos estágios de entrada DC LVDT de alta impedância de 1 M Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento térmico e alinhamento da gaiola de cartões:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA placa principal 176449-04 opera dentro de uma faixa de temperatura ambiente industrial de -30 a +65 °C. Ao executar implantações de rack de alta densidade, verifique se os ventiladores de ventilação do gabinete mantêm um fluxo de ar vertical limpo e constante ao longo das trilhas dos slots. Ao inserir o módulo do monitor no chassi do rack, deslize o substrato uniformemente ao longo dos guias do cartão para evitar dobrar os pinos do conector do backplane, e aperte manualmente os parafusos de polegar superior e inferior para garantir o aterramento estrutural de baixa resistência.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515325291,"sku":"3500\/45 176449-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-45-176449-04-position-monitor-4rrb2jhbz2i_0279879a-8618-4b86-948e-05407010c3b3.jpg?v=1765440075","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-176449-04-3500-45-position-monitor-1","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}