{"product_id":"bently-nevada-3300-12-power-supply-module","title":"Fonte de Alimentação AC Bently Nevada 3300\/12","description":"\u003cp\u003e\u003cspan class=\"citation-896\"\u003eO\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-896\"\u003eBently Nevada 3300\/12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-896\"\u003e\u003cspan\u003e \u003c\/span\u003eé uma fonte de alimentação CA que fornece energia confiável e regulada para até 12 monitores e seus transdutores associados dentro de um rack 3300\u003c\/span\u003e\u003cspan class=\"citation-896 citation-end-896\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-895\"\u003e\u003c\/span\u003eÉ instalado na posição mais à esquerda (Posição 1) do rack\u003cspan class=\"citation-895 citation-end-895\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan class=\"citation-894\"\u003e\u003c\/span\u003eEspecificações Técnicas\u003cspan class=\"citation-894 citation-end-894\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e1. Alimentação de Entrada\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003eOpções de Tensão\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e: Selecionável pelo usuário para\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e95 a 125 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(1,0 A máx.) ou\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e190 a 250 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(0,5 A máx.), monofásico, 50 a 60 Hz\u003c\/span\u003e\u003cspan class=\"citation-893 citation-end-893\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-892\"\u003eAlterável em Campo\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-892\"\u003e: A tensão de entrada pode ser alterada em campo via jumper soldado e substituição do fusível externo\u003c\/span\u003e\u003cspan class=\"citation-892 citation-end-892\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-891\"\u003eSurto de Ligação\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-891\"\u003e: 26 A de pico ou 12 A rms por um ciclo\u003c\/span\u003e\u003cspan class=\"citation-891 citation-end-891\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Saídas\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-890\"\u003eAlimentação do Transdutor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-890\"\u003e: Fornece tensão DC regulada internamente ao rack\u003c\/span\u003e\u003cspan class=\"citation-890 citation-end-890\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003eTensão Programável\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e: Programável em campo para\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-24 Vcc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+0%, -2,5%) ou\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-18 Vcc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+1%, -2%)\u003c\/span\u003e\u003cspan class=\"citation-889 citation-end-889\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-888\"\u003eProteção\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-888\"\u003e: Tensões do transdutor são protegidas contra sobrecarga em placas de circuito individuais do monitor\u003c\/span\u003e\u003cspan class=\"citation-888 citation-end-888\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"citation-887\"\u003e\u003c\/span\u003e\u003cstrong\u003e3. Relé OK\u003c\/strong\u003e\u003cspan class=\"citation-887 citation-end-887\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunção\u003c\/strong\u003e: Fornece uma indicação de status em nível de sistema.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-886\"\u003e\u003c\/span\u003eA perda da energia primária, falha do monitor ou falha na fiação do transdutor fará com que o relé mude de estado\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-885\"\u003eTipo\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-885\"\u003e: Pólo único, duplo contato (SPDT)\u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-884\"\u003eVedação\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-884\"\u003e: Hermeticamente selado\u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClassificações de Contato\u003c\/strong\u003e: 5 A a 28 Vcc ou 120 Vac;\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-883\"\u003e\u003c\/span\u003e3 A a 220 Vac (carga resistiva)\u003cspan class=\"citation-883 citation-end-883\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-882\"\u003eOperação\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-882\"\u003e: Normalmente energizado\u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-881\"\u003e\u003c\/span\u003e4. Físico \u0026amp; Ambiental\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-880\"\u003eTemperatura de Operação\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-880\"\u003e: 0°C a +65°C (+32°F a +150°F)\u003c\/span\u003e\u003cspan class=\"citation-880 citation-end-880\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-879\"\u003eTemperatura de Armazenamento\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-879\"\u003e: -40°C a +85°C (-40°F a +185°F)\u003c\/span\u003e\u003cspan class=\"citation-879 citation-end-879\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-878\"\u003eUmidade\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-878\"\u003e: Até 95% sem condensação\u003c\/span\u003e\u003cspan class=\"citation-878 citation-end-878\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-877\"\u003ePeso\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-877\"\u003e: 1 kg (2,2 lbs.)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-876\"\u003e\u003c\/span\u003eInformações para Pedido (Códigos de Sufixo)\u003cspan class=\"citation-876 citation-end-876\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFormato do Pedido: 3300\/12-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-875\"\u003eA: Opção de Tensão de Entrada\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-875\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-875 citation-end-875\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 95-125 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 190-250 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-874\"\u003eB: Opção de Módulo de Entrada de Energia (PIM)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-874\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-874 citation-end-874\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Padrão\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22\u003c\/strong\u003e: Barreiras de Segurança Internas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e23\u003c\/strong\u003e: Apenas fonte reserva (Sem PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-873\"\u003eC: Opção de Aprovação de Agência\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-873\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-873 citation-end-873\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Não Requerido\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-872\"\u003e01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-872\"\u003e: CSA\/NRTL\/C (Classe I, Div 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-872 citation-end-872\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-871\"\u003e02\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-871\"\u003e: Autocertificação ATEX\u003c\/span\u003e\u003cspan class=\"citation-871 citation-end-871\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eNotas Importantes para Instalação\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003eRedundância\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e: Uma segunda fonte de alimentação é\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003enunca necessário\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e\u003cspan\u003e \u003c\/span\u003eno mesmo rack 3300\u003c\/span\u003e\u003cspan class=\"citation-870 citation-end-870\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-869\"\u003eFiltragem de Ruído\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-869\"\u003e: O 3300\/12 vem equipado com um filtro de ruído de linha como padrão\u003c\/span\u003e\u003cspan class=\"citation-869 citation-end-869\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-868\"\u003eSegurança\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-868\"\u003e: É fortemente recomendado conectar um anunciador externo aos terminais do relé OK para garantir que os operadores sejam alertados sobre a perda da proteção da máquina\u003c\/span\u003e\u003cspan class=\"citation-868 citation-end-868\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855850347,"sku":"3300\/12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-12-power-supply-module-rdqathnprlx_e7da0184-0869-4ca4-9c0f-d1e92e31bca5.jpg?v=1765449181","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-3300-12-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}