{"product_id":"bently-nevada-330101-02-32-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-02-32-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-02-32-10-02-05\u003c\/strong\u003e is a high-precision \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e belonging to the industry-standard 3300 XL 8 mm Proximity Transducer System. This specific variant is configured with an unthreaded length of 0.2 inches and an overall case length of 3.2 inches, featuring a standard 3\/8-24 UNF thread. It is designed without mechanical armor, offering a lightweight and highly flexible cable routing profile suitable for installations where external protection is not required or is run through separate dedicated conduits.\u003c\/p\u003e\n\u003cp\u003eServing as a crucial component in vibration monitoring and machinery protection systems, this proximity probe utilizes the eddy-current operating principle to perform non-contact shaft vibration and axial position measurements. It interfaces seamlessly with a 330180 series Proximitor sensor and a 3300 XL standard extension cable to form a complete 5-meter or 9-meter transducer chain. The configuration terminates in a standard 1.0-meter (3.3 feet) cable with a Miniature coaxial ClickLoc connector (without a connector protector), assuring low-attenuation signal transmission. Certified under option code 05, this probe meets rigorous CSA, ATEX, and IECEx safety standards for dependable operation inside hazardous and explosive industrial areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRugged 8 mm tip diameter optimized for reliable eddy-current non-contact displacement monitoring.\u003c\/li\u003e\n  \u003cli\u003eCustom unthreaded length of 0.2 inches matched with a 3.2-inch threaded case length for targeted bracket positioning.\u003c\/li\u003e\n  \u003cli\u003eUnarmored design provides excellent flexibility for standard coaxial cable routing.\u003c\/li\u003e\n  \u003cli\u003eStandard 1.0-meter (3.3 feet) cable length designed to minimize slack in compact machinery setups.\u003c\/li\u003e\n  \u003cli\u003eTerminated with a high-durability Miniature coaxial ClickLoc connector for a robust electrical interface.\u003c\/li\u003e\n  \u003cli\u003eAgency approval option 05 provides native compliance with ATEX, IECEx, and CSA hazardous location directives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used globally in heavy industries (power generation, oil and gas, and chemical processing) to protect critical rotating assets, such as:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and thrust position analysis.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor and high-volume pump rotor displacement monitoring.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protective shutdowns.\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearbox, motor, and generator bearing casing installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e0.2 inches (5.1 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32\u003c\/td\u003e\n      \u003ctd\u003e3.2 inches (81.3 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-02-32-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current non-contact sensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 inches (5.1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.2 inches (81.3 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature ClickLoc coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored standard cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure precise signal calibration and prevent physical damage to the equipment, the following installation guidelines must be followed:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways set the physical probe gap using a calibrator or voltmeter to match the system scale factor (typically gapped at 1.27 mm or 50 mils).\u003c\/li\u003e\n  \u003cli\u003eEnsure the target shaft surface is clean, free of scratches, and constructed of standard AISI 4140 steel for optimal calibration alignment.\u003c\/li\u003e\n  \u003cli\u003eAvoid exceeding maximum thread engagement limits (0.563 inches for 3\/8-24 UNF threads) during installation on the machine casing.\u003c\/li\u003e\n  \u003cli\u003eRoute cables with appropriate shielding and electrical grounding techniques to mitigate potential industrial noise or interference.\u003c\/li\u003e\n  \u003cli\u003eObserve all intrinsic safety barriers and drawing parameters when deploying inside certified hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCertification Body\u003c\/th\u003e\n      \u003cth\u003eApproval Standard\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90degC...T280degC Dc, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCSA \/ NRTL\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntrinsically Safe and Non-Incendive for Class I, Div 1 \u0026amp; 2 installations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCompliant with standard environmental guidelines\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666762592619,"sku":"330101-02-32-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-02-32-10-02-05-interconnect-cable-srjkkre4nru_e8eb68fe-37e8-4334-8e8d-70dfe191d6f1.jpg?v=1765447154","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330101-02-32-10-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}