{"product_id":"bently-nevada-330130-080-00-00-3300-xl-standard-extension-cable","title":"Cabo de Extensão Padrão Bently Nevada 330130-080-00-00 3300 XL","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 meters cable length) and Option 00 (standard unarmored cable with standard connectors) specify the configuration for this 3300 XL standard extension cable — \u003cstrong\u003e330130-080-00-00\u003c\/strong\u003e. This configuration utilizes a 75 Ohm triaxial fluoroethylene propylene (FEP) insulated cable to link the proximity probe to the Proximitor sensor. It includes standard gold-plated ClickLoc miniature coaxial connectors on both ends without pre-installed connector protectors or external stainless steel armor. The total length of 8.0 meters is selected for transducer configurations where the combined length of the proximity probe and the extension cable must match the required total system length of 9.0 meters (with a 1.0-meter probe).\u003c\/p\u003e\n\n\u003cp\u003eThe FEP insulation provides resistance to lubricating oils, industrial solvents, and moisture in process environments at operating temperatures up to 177 degC. Unlike sibling variants such as the 330130-080-01-00 (which features stainless steel protective armor) or the 330130-080-02-00 (which features pre-installed connector protectors), this unarmored standard version provides maximum routing flexibility and a minimal cable diameter of 3.70 mm. This design facilitates installation through narrow conduit runs or tight bends where mechanical abrasion is not a primary concern. The standard gold-plated click-type connectors provide electrical connection and prevent loosening under vibration without requiring special installation tools.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 080 specifies an 8.0-meter (26.2 feet) physical cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 00 standard unarmored configuration with 75 Ohm triaxial FEP insulation.\u003c\/li\u003e\n  \u003cli\u003eClickLoc miniature coaxial connectors feature gold plating and a finger-tight locking mechanism.\u003c\/li\u003e\n  \u003cli\u003eFEP cable insulation resists degradation from exposure to lubricating oils and process chemicals.\u003c\/li\u003e\n  \u003cli\u003eSupports standard operating temperature range from -51 degC to +177 degC.\u003c\/li\u003e\n  \u003cli\u003eMaintains a constant system capacitance of 69.9 pF\/m to match Proximitor calibration requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical industrial applications for this standard extension cable include rotating machinery monitoring in sectors such as power generation, petrochemicals, oil and gas, and water treatment. It is used to connect 3300 XL 8 mm proximity probes to Proximitor sensors for measurements of:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft radial vibration\u003c\/li\u003e\n  \u003cli\u003eAxial position (thrust displacement)\u003c\/li\u003e\n  \u003cli\u003ePhase reference (Keyphasor)\u003c\/li\u003e\n  \u003cli\u003eEccentricity and speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-080-00-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, FEP insulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector Protector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eStandard cable (unarmored, no connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-080-00-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature gold-plated ClickLoc coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Standard unarmored cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Core)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.76 Ohm +\/- 0.26 Ohm (Center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.53 Ohm +\/- 0.11 Ohm (Outer conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 lbf) maximum rated tension at connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.27 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (coiled\/packaged)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 mm x 200 mm x 30 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.70 mm (0.15 in) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection End\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eTarget Component\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe End\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial female ClickLoc\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe connector (male)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor End\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial male ClickLoc\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor sensor connector (female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following installation guidelines for the extension cable to maintain measurement integrity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the combined length of the extension cable and proximity probe matches the calibration requirements of the Proximitor sensor (typically a total length of 9.0 meters).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) throughout the cable routing to avoid internal conductor damage or impedance alterations.\u003c\/li\u003e\n  \u003cli\u003eUse caution when pulling unarmored cable through conduit to prevent sharp bends or snagging on sharp edges.\u003c\/li\u003e\n  \u003cli\u003eEnsure ClickLoc connectors are joined finger-tight; a physical \"click\" indicates proper seating and locking. Do not use pliers or other mechanical tools on standard ClickLoc connectors unless mating with non-XL stainless steel connectors.\u003c\/li\u003e\n  \u003cli\u003eIsolate the coaxial connectors from potential machine grounding paths by routing the connections within dedicated junction boxes or using non-conductive sleeves.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis configuration (Option C: 00) is classified as not requiring specific agency approvals. It does not carry hazardous area certifications such as ATEX, IECEx, or CSA. For applications within explosive or hazardous atmospheres, please select the Option 05 variant (e.g., 330130-080-00-05).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666854113643,"sku":"330130-080-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-00-00-extension-cable-awkj2smst3e_3669777c-e5f5-4ecb-a113-cf3b350125c9.jpg?v=1765449131","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330130-080-00-00-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}