{"product_id":"bently-nevada-330180-10-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-10-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-10-05\u003c\/strong\u003e specifies a 3300 XL Proximitor Sensor configured for a 1.0 m system length and designed for panel-mount applications. This sensor conditions and drives the proximity probe signal in non-contact eddy-current measurement chains, converting raw probe output into a linear voltage displacement signal. The integration of Option 10 dictates that the sensor is calibrated for a 1.0 m total system length (typically used in direct-probe or short-range configurations without an extension cable) and comes with a 4-hole panel-mount base.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration includes Option 05 agency approvals, qualifying the module for use under CSA, ATEX, and IECEx hazardous area certifications. In contrast to standard non-approved configurations (Option 00) or DIN-rail mounted variants (such as Option 11), the panel-mount base of the 330180-10-05 maintains the classic footprint compatible with older Proximitor styles. It features built-in electrical isolation, removing any necessity for separate isolator plates in high-density installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 10 defines a 1.0 m (3.3 ft) system calibration length, configured specifically for panel-mount installations with a 4-hole footprint.\u003c\/li\u003e\n\u003cli\u003eOption 05 designates CSA, ATEX, and IECEx hazardous area certification, enabling installation under intrinsically safe and non-incendive parameters.\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strip provides robust field-wiring connections without the need for special installation tools.\u003c\/li\u003e\n\u003cli\u003eA308 aluminum housing construction offers resistance to radio frequency interference (RFI) and electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eCoaxial ClickLoc connector interface secures the sensor-to-cable attachment for structural stability.\u003c\/li\u003e\n\u003cli\u003e-17.5 Vdc to -26 Vdc power supply input compatibility supports connection to 3500 monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical heavy-industry machinery monitoring applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position measurement on high-speed turbines and compressors.\u003c\/li\u003e\n\u003cli\u003eShaft eccentricity and thermal expansion monitoring on utility generators and electric motors.\u003c\/li\u003e\n\u003cli\u003eGeneral rotating machinery protection systems requiring ATEX\/IECEx certified intrinsically safe sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330180-10-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-10-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e-1 Vdc to -17 Vdc (displacement over 2.0 mm linear range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA308 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.246 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eLess than 3% ASF change in 93% humidity up to 56 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Label\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003eVoltage Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon\/System Ground Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eLinear Analog Output Signal (-1 to -17 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the Proximitor sensor directly to a flat panel using the standard 4-hole mounting footprint.\u003c\/li\u003e\n\u003cli\u003eEnsure proper electrical isolation by utilizing the integrated isolation base, preventing ground loops.\u003c\/li\u003e\n\u003cli\u003eUse a 3-conductor shielded triad cable (0.2 to 1.5 mm2 or 16 to 24 AWG) for field wiring connections to the monitor.\u003c\/li\u003e\n\u003cli\u003eStrip field wires to the recommended length before inserting into the SpringLoc terminal strip.\u003c\/li\u003e\n\u003cli\u003eEnsure the coaxial connection is finger-tight (0.565 Nm maximum torque) to prevent damage to gold contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA (Class I, Division 2, Groups A, B, C, D)\u003c\/li\u003e\n\u003cli\u003eATEX (Ex ia IIC T4\/T5 Ga, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc)\u003c\/li\u003e\n\u003cli\u003eIECEx (Ex ia IIC T4\/T5 Ga, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc)\u003c\/li\u003e\n\u003cli\u003eCE Mark\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666621165931,"sku":"330180-10-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-10-05-3300-xl-proximitor-sensor-wv345e10lph_32892a72-a270-4925-8e24-fb914165da2e.jpg?v=1765444259","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330180-10-05-3300-xl-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}