{"product_id":"bently-nevada-330180-51-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-51-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configuration featuring a 5.0-meter system length compatibility and an integrated DIN-rail mounting base. This specific variant is specified with the 00 option code, indicating that it does not carry hazardous area agency approvals. The device houses the high-frequency oscillator and demodulator circuitry necessary to condition raw displacement data from a compatible 3300 XL 8 mm proximity probe and extension cable. It converts the physical gap between the probe tip and the target material into a continuous, linear analog voltage output proportional to shaft movement.\u003c\/p\u003e\n\u003cp\u003eBy pairing the sensor with a 5.0-meter total system length probe and extension cable, the measurement system maintains its linear calibration across a full 2.0 mm (80 mils) dynamic range. The integrated mounting base of this variant provides built-in electrical isolation, preventing ground loops and eliminating the need for separate isolator plates. The spring-loaded terminal strips provide secure field-wiring connections without requiring manual screw-type clamping.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 51 specifies compatibility with a 5.0-meter total system length and incorporates a 35 mm DIN-rail mount.\u003c\/li\u003e\n\u003cli\u003eOption 00 designates a standard build where special hazardous area certifications are not required.\u003c\/li\u003e\n\u003cli\u003eIntegrated SpringLoc terminal strips facilitate field-wiring installations without specialized tooling.\u003c\/li\u003e\n\u003cli\u003eIsolating mounting base prevents electromagnetic interference and ground-loop noise.\u003c\/li\u003e\n\u003cli\u003eBroad compatibility with standard 3300 XL 8 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis Proximitor sensor is used for machinery vibration, position, and shaft keyphasor measurements in standard industrial environments. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating process compressors\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial pumps and gearboxes\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generator shaft bearings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor, 5.0 meters, DIN-rail mount, standard approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length \u0026amp; Mounting Option\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) system length, DIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ SKU\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail mount (Option 51)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capability\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300-series 5 mm or 3300 XL 8 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc; 12 mA maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Strip Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e89.4 mm x 81.3 mm x 61.0 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Label\u003c\/th\u003e\n\u003cth\u003eConnection Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog displacement signal output to monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem common \/ signal ground reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting base is locked onto a standard 35 mm DIN rail. Provide a minimum of 3.05 mm (0.120 inches) of vertical clearance above the housing to facilitate standard removal from the rail. Use three-conductor shielded triad cables for field wiring to connect terminals to the monitor. Keep field wiring within the maximum distance limit of 305 meters (1000 feet) to prevent output signal attenuation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Standard\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eComplies with European electromagnetic compatibility (EMC) standards without special shielded conduit or housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519781739,"sku":"330180-51-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor-proximity-switch-24ni1ysosth_23365f6d-1973-456e-ab2a-a90ed88b27f2.jpg?v=1765440141","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}