{"product_id":"bently-nevada-330703-000-100-10-11-05-3300-xl-11-mm-proximity-probe","title":"Sonda de Proximidade Bently Nevada 330703-000-100-10-11-05 3300 XL 11 mm","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330703-000-100-10-11-05\u003c\/strong\u003e is an unarmored, metric-threaded \u003cstrong\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e configured with a M14 x 1.5 thread, 0 mm of unthreaded length, a 100 mm overall case length, a 1.0 meter total length FluidLoc cable, a miniature coaxial ClickLoc connector with an integrated connector protector, and Multiple Approvals.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration incorporates a specialized FluidLoc cable (Option 11) which features an internal block designed to prevent lubrication oil or process fluids from migrating through the inside of the triaxial cable. In addition, the factory-installed connector protector seals the critical probe-to-extension cable junction against environmental contaminants, while the unarmored M14 x 1.5 case allows direct installation into standard machinery housings without the extra routing bulk or bend limits associated with stainless steel armor options.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM14 x 1.5 metric threaded configuration (base model 330703) without stainless steel armor for direct installation in standard machinery casings.\u003c\/li\u003e\n  \u003cli\u003eOption 000 unthreaded length providing a fully threaded 0 mm unthreaded probe body to optimize case engagement.\u003c\/li\u003e\n  \u003cli\u003eOption 100 overall case length specifying a 100 mm long threaded stainless steel casing.\u003c\/li\u003e\n  \u003cli\u003eOption 10 total length indicating a 1.0 meter (3.3 feet) integrated triaxial probe cable.\u003c\/li\u003e\n  \u003cli\u003eOption 11 FluidLoc cable type designed with a internal block to halt moisture and oil migration inside the cable.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector with an integrated connector protector to guard the connector junction against severe fluids.\u003c\/li\u003e\n  \u003cli\u003eOption 05 Multiple Approvals package certified for ATEX, IECEx, and CSA hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip bonded structurally to the AISI 304 stainless steel probe case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial thrust position measurements on utility steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRamp differential expansion measurements in large-scale power generation machinery.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and shaft position monitoring on fluid-film bearing systems.\u003c\/li\u003e\n  \u003cli\u003eRod drop and rod position measurements in critical reciprocating compressors.\u003c\/li\u003e\n  \u003cli\u003eTachometer and zero-speed sensing applications.\u003c\/li\u003e\n  \u003cli\u003ePhase reference (Keyphasor) signal generation for speed and phase tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330703-000-100-10-11-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Probe, M14 x 1.5 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n      \u003ctd\u003e100 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e11\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-000-100-10-11-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Thread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 metric thread (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP insulated FluidLoc cable (oil barrier)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with factory-installed connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), starting at 0.5 mm (20 mils) from target (range 0.5 to 4.5 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% (when used with matching system components)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.10 mm (+\/-4 mils) standard; less than +\/-0.15 mm (+\/-6 mils) over extended temperatures\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/- 0.5 ohms (typical at 1.0 m total length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Thread Engagement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e21 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb) maximum rated; 21.1 N-m (187 in-lb) recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDamp Heat Testing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTested to IEC 68-2-3 damp heat standards\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to lead; 270 N (60 lb) probe lead to extension cable connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Size (Flat Surface)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30.5 mm (1.2 in) minimum recommended diameter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e152 mm (6.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eObserve the maximum thread engagement limit of 21 mm for the M14 x 1.5 probe case to prevent binding or thread deformation during assembly.\u003c\/li\u003e\n  \u003cli\u003eUtilize the recommended installation torque of 21.1 N-m (187 in-lb) during mounting, and never exceed the maximum rated limit of 63.3 N-m (560 in-lb).\u003c\/li\u003e\n  \u003cli\u003eEnsure the target area on the observed machinery shaft has a flat surface diameter of at least 30.5 mm (1.2 in) and the overall shaft diameter is at least 152 mm (6.0 in).\u003c\/li\u003e\n  \u003cli\u003eEstablish the initial physical gap setting of 2.5 mm (100 mils) from the target to operate within the linear center of the transducer calibration curve.\u003c\/li\u003e\n  \u003cli\u003eDo not expose the probe assembly to operating temperatures below -34 degC in systems requiring active pressure sealing to avoid degrading the Viton O-ring seal.\u003c\/li\u003e\n  \u003cli\u003eMaintain a continuous minimum cable bend radius of 25.4 mm (1.0 in) to prevent coaxial signal degradation or conductor wear.\u003c\/li\u003e\n  \u003cli\u003eVerify that the factory-installed connector protector is fully seated over the miniature coaxial ClickLoc junction to prevent oil or moisture entry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e: Intrinsically Safe (Ex ia IIC T5...T1 Ga) and Non-Sparking\/Increased Safety (Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc) when installed per Bently Nevada drawings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (CSA)\u003c\/strong\u003e: Class I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Division 2, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark\u003c\/strong\u003e: Compliant with European Community Directive 2014\/30\/EU (EMC Directive) and 2011\/65\/EU (RoHS Directive).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: SIL 2 capable (HFT=0), SIL 3 capable (HFT=1) when configured inside an appropriate safety-instrumented system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaritime\u003c\/strong\u003e: Compliant with marine classification standards for marine propulsion and offshore platforms.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666551075179,"sku":"330703-000-100-10-11-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-000-100-10-11-05-proximity-probes-jwaiuxzhqtf_1e66e030-dcc0-4a74-b160-bf85d3426f0f.jpg?v=1765440590","url":"https:\/\/www.plcprotech.com\/pt\/products\/bently-nevada-330703-000-100-10-11-05-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}